High-resolution lensless Fourier-transform digital holography

被引:8
作者
Bányász, I [1 ]
Kornis, J [1 ]
机构
[1] Hungarian Acad Sci, Dept Crystal Phys, Res Inst Solid State Phys & Opt, H-1525 Budapest, Hungary
来源
OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION IV, PTS 1 AND 2 | 2005年 / 5856卷
关键词
digital holography; holographic microscopy; high-resolution holography; numerical hologram reconstruction; Fresnel-Kirchhoff integral;
D O I
10.1117/12.612834
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this work was to study the possibility of improving the resolution of digital holography. To achieve this goal we recorded digital holograms of microlines of width in the micrometer region in a lensless Fourier-transform setup. In such a way spatial frequency of the hologram can be reduced in high numerical aperture geometry. A He-Ne laser was used in the experiments. Holographic images of the test objects were reconstructed using two methods. The first one is based on fast Fourier-transform algorithm. The second one uses Monte-Carlo method. In our paper we present a comparative analysis of the reconstructed holographic images using these methods. The effects of limited resolution and nonlinearity of the CCD on the reconstructed image were included in the numerical reconstruction by multiplying the integrand of the Fresnel-Kirchhoff integral by the product of two functions, describing of the above characteristic of the CCD. This method can serve as a basis for resolution enhancement in DH via de-convolution.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 31 条
[1]   Particle size and position measurement with digital holography [J].
Adams, M ;
Kreis, TM ;
Juptner, WPO .
OPTICAL INSPECTION AND MICROMEASUREMENTS II, 1997, 3098 :234-240
[2]   METHOD FOR THE EVALUATION OF THE EFFECTS OF FILM NONLINEARITIES ON THE HOLOGRAPHIC IMAGE [J].
BANYASZ, I .
OPTICS LETTERS, 1993, 18 (08) :658-660
[3]   HOLOGRAPHIC IMAGE OF A POINT-SOURCE IN THE PRESENCE OF MISALIGNMENT [J].
BANYASZ, I ;
KISS, G ;
VARGA, P .
APPLIED OPTICS, 1988, 27 (07) :1293-1297
[4]   RESOLUTION IN HOLOGRAPHY [J].
CHAMPAGN.EB ;
MASSEY, NG .
APPLIED OPTICS, 1969, 8 (09) :1879-&
[5]  
CHAMPAGNE EB, 1965, JOSA, V55, P987
[6]   Digital holography for quantitative phase-contrast imaging [J].
Cuche, E ;
Bevilacqua, F ;
Depeursinge, C .
OPTICS LETTERS, 1999, 24 (05) :291-293
[7]   Spatial filtering for zero-order and twin-image elimination in digital off-axis holography [J].
Cuche, E ;
Marquet, P ;
Depeursinge, C .
APPLIED OPTICS, 2000, 39 (23) :4070-4075
[8]  
De Nicola S, 2002, OPT LASER ENG, V37, P331, DOI 10.1016/S0143-8166(01)00087-2
[9]   Correct-image reconstruction in the presence of severe anamorphism by means of digital holography [J].
De Nicola, S ;
Ferraro, P ;
Finizio, A ;
Pierattini, G .
OPTICS LETTERS, 2001, 26 (13) :974-976
[10]   Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence [J].
Dubois, F ;
Joannes, L ;
Legros, JC .
APPLIED OPTICS, 1999, 38 (34) :7085-7094