Characteristic Frequency of Travelling Waves Applied for Transmission Lines Fault Location Estimation

被引:0
作者
Iurinic, L. U. [1 ]
Ferraz, R. G. [1 ]
Bretas, A. S. [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Dept Elect Engn, Porto Alegre, RS, Brazil
来源
2013 IEEE GRENOBLE POWERTECH (POWERTECH) | 2013年
关键词
characteristic frequency; fault location; frequency spectrum; travelling waves; wavefronts;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an analytical approach for determining the characteristic frequency of transient signals generated from transmission lines faults. Transient signals of travelling waves generated by faults contain very important information about the fault distance. Therefore, the characteristic frequency can be used for transmission lines fault distance estimation. In order to demonstrate the effectiveness of the developed equations, five cases are simulated using different values for equivalent impedance of local terminal and maintaining the fault distance at 120 km from the sending-end. Results obtained show a good correlation between measured and calculated characteristic frequency allowing very good accuracy for fault distance estimation.
引用
收藏
页数:5
相关论文
共 11 条
[1]  
[Anonymous], 1926, Bell Syst Tech J, DOI DOI 10.1002/J.1538-7305.1926.TB00122.X
[2]   Accurate fault location technique for distribution system using fault-generated high-frequency transient voltage signals [J].
Bo, ZQ ;
Weller, G ;
Redfern, MA .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (01) :73-79
[3]   Integrated Use of Time-Frequency Wavelet Decompositions for Fault Location in Distribution Networks: Theory and Experimental Validation [J].
Borghetti, A. ;
Bosetti, M. ;
Nucci, C. A. ;
Paolone, M. ;
Abur, A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :3139-3146
[4]   Travelling wave based fault location for teed circuits [J].
Evrenosoglu, CY ;
Abur, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1115-1121
[5]  
Lopes F. V., P 2011 INN SMART GRI
[6]   Fault location using wavelets [J].
Magnago, FH ;
Abur, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) :1475-1480
[7]   ACCURATE MODELING OF FREQUENCY-DEPENDENT TRANSMISSION-LINES IN ELECTROMAGNETIC TRANSIENT SIMULATIONS [J].
MARTI, JR .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (01) :147-157
[8]  
Miano Giovanni, 2001, TRANSMISSION LINES L, P64
[9]   Location of DC Line Faults in Conventional HVDC Systems With Segments of Cables and Overhead Lines Using Terminal Measurements [J].
Nanayakkara, O. M. K. Kasun ;
Rajapakse, Athula D. ;
Wachal, Randy .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) :279-288
[10]  
Saha MM, 2010, POWER SYST, P1, DOI 10.1007/978-1-84882-886-5