High-flux dialysis lowers plasma leptin concentration in chronic dialysis patients

被引:38
|
作者
Coyne, DW
Dagogo-Jack, S
Klein, S
Merabet, E
Audrain, J
Landt, M
机构
[1] Washington Univ, Sch Med, Dept Internal Med, Div Renal,Chromalloy Amer Kidney Ctr, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pediat, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Dept Internal Med, Div Endocrine, St Louis, MO 63110 USA
关键词
hemodialysis; biocompatible membranes; leptin; high-flux dialysis;
D O I
10.1016/S0272-6386(98)70079-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Leptin is a protein produced by fat cells and involved in body weight regulation, Plasma leptin is significantly higher in some hemodialysis (HD) patients than in normal controls. We examined the influence of dialyzer membrane biocompatibility and flux on elevated plasma leptin concentrations in hemodialysis patients. Employing a crossover design, leptin and tumor necrosis factor alpha (TNF alpha) revels were serially determined in eight chronic dialysis patients. Patients were dialyzed sequentially on low-flux cellulosic (TAF) dialyzers, low-flux (F8) polysulfone, high-flux (F80B) polysulfone, then low-flux polysulfone and cellulosic dialyzers again. Mean leptin concentrations were similar when low-flux polysulfone or cellulosic dialyzers were employed (141.9 +/- 24.2 mu g/L versus 137.8 +/- 18.4 mu g/L, respectively (P = NS), In contrast, leptin fell significantly on the high-flux polysulfone dialyzer (99.4 +/- 16.2 mu g/L) compared with cellulosic (P < 0.005), and low-flux polysulfone dialyzers (P < 0.02). Leptin clearance by the high-flux polysulfone dialyzer was significantly higher than the low-flux dialyzers (50.4 +/- 21.5 v -9.6 +/- 10.3 mL/min; P = 0.043), but did not account fully for the 30% decline in plasma leptin during the high-flux arm of the study. Concentrations of TNF alpha. were lower when high-flux polysulfone dialyzers were employed, but there was no correlation of individual TNF alpha levels with leptin concentrations, High-flux dialysis lowers plasma leptin concentrations an average of 30%, but biocompatibility does not influence leptin levels. The decrease in plasma leptin on high-flux dialysis cannot be explained solely by enhanced clearance. (C) 1998 by the National Kidney Foundation, Inc.
引用
收藏
页码:1031 / 1035
页数:5
相关论文
共 50 条
  • [1] Effect of high-flux dialysis on the anaemia of haemodialysis patients
    Locatelli, F
    Andrulli, S
    Pecchini, F
    Pedrini, T
    Agliata, S
    Lucchi, L
    Farina, M
    La Milia, V
    Grassi, C
    Borghi, M
    Redaelli, B
    Conte, F
    Ratto, G
    Cabiddu, G
    Grossi, C
    Modenese, R
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (09) : 1399 - 1409
  • [2] IMPORTANCE OF ENDOTOXINS IN HIGH-FLUX DIALYSIS
    SMOLLICH, BP
    FALKENHAGEN, D
    SCHNEIDEWIND, J
    MITZNER, S
    KLINKMANN, H
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 : 83 - 85
  • [3] IMPORTANCE OF ENDOTOXINS IN HIGH-FLUX DIALYSIS
    KLINKMANN, H
    FALKENHAGEN, D
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1992, 7 (08) : 884 - 885
  • [4] HIGH-FLUX DIALYSIS MEMBRANES IMPROVE LIPID PROFILE IN CHRONIC-HEMODIALYSIS PATIENTS
    BLANKESTIJN, PJ
    VOS, PF
    RABELINK, TJ
    VANRIJN, HJM
    JANSEN, H
    KOOMANS, HA
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 5 (09): : 1703 - 1708
  • [5] THE EFFECT OF HIGH-FLUX HEMODIALYSIS ON QUALITY OF LIFE IN DIALYSIS PATIENTS
    Pusevski, V.
    Mladenovska, D.
    Trajcevska, L.
    Gelev, S.
    Amitov, V.
    Sikole, A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 485 - 485
  • [6] COMPARISON OF MORBIDITY IN HIGH-FLUX DIALYSIS (HFD) AND CONVENTIONAL DIALYSIS (CD)
    KEEN, M
    EVANS, M
    GOTCH, F
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 235 - 235
  • [7] IMPROVEMENT OF PLASMA-LIPOPROTEIN PROFILES DURING HIGH-FLUX DIALYSIS
    SERES, DS
    STRAIN, GW
    HASHIM, SA
    GOLDBERG, IJ
    LEVIN, NW
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1993, 3 (07): : 1409 - 1415
  • [8] CLEARANCE OF VANCOMYCIN BY HIGH-FLUX DIALYSIS MEMBRANES
    REETZE, P
    BOEHLER, J
    KELLER, E
    KRAMER, A
    SCHOLLMEYER, PJ
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1990, 19 (11) : 504 - 505
  • [9] THE HIGH-FLUX DIALYSIS (HFD) PRESCRIPTION (P)
    GOTCH, F
    KEEN, M
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 232 - 232
  • [10] Vancomycin clearance with high-flux dialysis membranes
    Anandan, JV
    Touchette, MA
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03): : 131 - 133