Dry-cured ham tissue characterization by fast field cycling NMR relaxometry and quantitative magnetization transfer

被引:18
作者
Bajd, Franci [1 ,2 ]
Gradisek, Anton [1 ]
Apih, Tomaz [1 ]
Sersa, Igor [1 ,2 ]
机构
[1] Jozef Stefan Inst, Jamova 39, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Math & Phys, Jadranska 19, Ljubljana 1000, Slovenia
关键词
dry-cured ham; protein concentration; dehydration; quadrupolar peaks; NMR relaxometry; magnetization-transfer NMR; CROSS-RELAXATION; ARTICULAR-CARTILAGE; MEAT-PRODUCTS; MRI; TIME; PARAMETERS; MUSCLE; BRAIN; PIGS;
D O I
10.1002/mrc.4462
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fast field cycling (FFC) and quantitative magnetization transfer (qMT) NMR methods are two powerful tools in NMR analysis of biological tissues. The qMT method is well established in biomedical NMR applications, while the FFC method is often used in investigations of molecular dynamics on which longitudinal NMR relaxation times of the investigated material critically depend. Despite their proven analytical potential, these two methods were rarely used in NMR studies of food, especially when combined together. In our study, we demonstrate the feasibility of a combined FFC/qMT-NMR approach for the fast and nondestructive characterization of dry-curing ham tissues differing by protein content. The characterization is based on quantifying the pure quadrupolar peak area (area under the quadrupolar contribution of dispersion curve obtained by FFC-NMR) and the restricted magnetization pool size (obtained by qMT-NMR). Both quantities correlate well with concentration of partially immobilized, nitrogen-containing and proton magnetization exchanging muscle proteins. Therefore, these two quantities could serve as potential markers for dry-curing process monitoring. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:827 / 834
页数:8
相关论文
共 36 条
[1]   Technologies to shorten the drying period of dry-cured meat products [J].
Arnau, J. ;
Serra, X. ;
Comaposada, J. ;
Gou, P. ;
Garriga, M. .
MEAT SCIENCE, 2007, 77 (01) :81-89
[2]   Use of multiparametric magnetic resonance microscopy for discrimination among different processing protocols and anatomical positions of Slovenian dry-cured hams [J].
Bajd, Franci ;
Skrlep, Martin ;
Candek-Potokar, Marjeta ;
Vidmar, Jernej ;
Sersa, Igor .
FOOD CHEMISTRY, 2016, 197 :1093-1101
[3]   Detection of osteoarthritis in knee and hip joints by fast field-cycling NMR [J].
Broche, Lionel M. ;
Ashcroft, George P. ;
Lurie, David J. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) :358-362
[4]   Measurement of fibrin concentration by fast field-cycling NMR [J].
Broche, Lionel M. ;
Ismail, Saadiya R. ;
Booth, Nuala A. ;
Lurie, David J. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) :1453-1457
[5]   Factors in pig production that impact the quality of dry-cured ham: a review [J].
Candek-Potokar, M. ;
Skrlep, M. .
ANIMAL, 2012, 6 (02) :327-338
[6]   SIFT-MS analysis of Iberian hams from pigs reared under different conditions [J].
Carrapiso, Ana I. ;
Noseda, Bert ;
Garcia, Carmen ;
Reina, Raquel ;
Sanchez del Pulgar, Jose ;
Devlieghere, Frank .
MEAT SCIENCE, 2015, 104 :8-13
[7]   Molecular basis of water proton relaxation in gels and tissue [J].
Chavez, Fabian Vaca ;
Halle, Bertil .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :73-81
[8]  
Cowan B. P., 1997, NUCL MAGNETIC RESONA, Vxxii, P434
[9]   Use of Magnetic Resonance Imaging for monitoring Parma dry-cured ham processing [J].
Fantazzini, P. ;
Gombia, M. ;
Schembri, P. ;
Simoncini, N. ;
Virgili, R. .
MEAT SCIENCE, 2009, 82 (02) :219-227
[10]   Prediction of salt and water content in dry-cured hams by computed tomography [J].
Fulladosa, E. ;
Santos-Garces, E. ;
Picouet, P. ;
Gou, P. .
JOURNAL OF FOOD ENGINEERING, 2010, 96 (01) :80-85