Theoretical and experimental investigation on the application of solar water heater coupled with air humidifier for regeneration of liquid desiccant

被引:38
作者
Alosaimy, A. S. [2 ]
Hamed, Ahmed M. [1 ,2 ]
机构
[1] Mansoura Univ, Dept Power Mech Engn, Fac Engn, Mansoura, Egypt
[2] Taif Univ, Dept Mech Engn, Fac Engn, Al Hawyah, Saudi Arabia
关键词
Solar energy; Dehumidification; Regeneration; Absorption; Desiccant; ARTIFICIAL NEURAL-NETWORKS; CYCLE; SYSTEMS; SIMULATION;
D O I
10.1016/j.energy.2011.05.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Theoretical and experimental investigation on the application of flat plate solar water heater coupled with air humidifier for regeneration of liquid desiccant has been presented in this work. The heated water from the storage tank of the solar heating system is circulated in a finned tube air heater. Hot air from the air heater is blown through a packing of a honeycomb type for the purpose of regeneration of calcium chloride (CaCl2) solution. An experimental system has been designed and installed for this purpose. The system comprises a solar water heater with a storage tank connected to an air/water heat exchanger. Hot air from the heat exchanger is blown to the air humidifier, which functions in this study as a regenerator. Calcium chloride solution is applied as the working desiccant in this study. Solution concentration is determined at the end of regeneration process and the mass of evaporated water is evaluated. It is observed that the heating temperature varies, at day time, in a range of about 5 degrees C. This limited variation in hot water temperature demonstrates the importance of the storage tank to attain a nearly steady state operation of the system. Experimental results show that solution with 30% concentration can be regenerated up to 50% using solar energy. In the theoretical part of this study, a multiple-layer artificial neural network (ANN) model has been applied to study the performance of a solar liquid-desiccant dehumidification/regeneration system when calcium chloride solution is applied as the working desiccant. The experimental results of the present study are used to construct and test the ANN model. Then the model has been utilized to describe and analyze the effect of the inlet conditions of air on the regeneration process. Good agreement between the outputs from the ANN model and the corresponding results from the experimental data has been found. The proposed model can work well as a predictive tool to complement the experiments. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3992 / 4001
页数:10
相关论文
共 50 条
[41]   Development and application of a dynamic model for a solar assisted liquid desiccant air conditioning system [J].
Zhong, Dan ;
Wen, Tao ;
She, Xiaohui ;
Chen, Yi ;
Wang, Meng ;
Yang, Hongxing ;
Luo, Yimo .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (02) :128-138
[42]   Research on liquid desiccant air conditioning system driven by natural cold source and solar energy regeneration [J].
Liang Z. ;
Li Q. .
Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (06) :211-215
[43]   Direct contact membrane distillation for liquid desiccant regeneration and fresh water production: Experimental investigation, response surface modeling and optimization [J].
Liu, Jingjing ;
Ren, Haoshan ;
Hai, Faisal, I ;
Albdoor, Ahmed K. ;
Ma, Zhenjun .
APPLIED THERMAL ENGINEERING, 2021, 184
[44]   Experimental investigation and model validation for liquid desiccant dehumidification and regeneration in falling-film plate [J].
Qian, Junfei ;
Yin, Yonggao ;
Pan, Xiongwei ;
Zhang, Xiaosong .
Huagong Xuebao/CIESC Journal, 2014, 65 (06) :2070-2077
[45]   Similarity of coupled heat and mass transfer between air-water and air-liquid desiccant direct-contact systems [J].
Liu, Xiao-Hua ;
Li, Zhen ;
Jiang, Yi .
BUILDING AND ENVIRONMENT, 2009, 44 (12) :2501-2509
[46]   Analysis of a Coupled Air-Based Solar Collector and Heat Pump Water Heater in Canada and the United States [J].
Treichel, Calene ;
Cruickshank, Cynthia A. .
PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, :673-684
[47]   Experimental Investigation of the Performance of a Double-Pass Unglazed Transpired Solar Air Heater [J].
Rabha, D. K. ;
Pathak, D. ;
Baruah, R. ;
Kalita, T. ;
Sharma, A. .
ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, :571-584
[48]   Performance evaluation of a rotary dehumidifier with molecular sieve desiccant using coupled regeneration mode: Experimental investigation [J].
Mehare H.B. ;
Hussain T. ;
Zia M.A. ;
Saleem S. .
Energy and Built Environment, 2025, 6 (02) :219-229
[49]   Experimental optimization of the heating element for a direct-coupled solar photovoltaic water heater [J].
Hachchadi, Oussama ;
Tapsoba, Gildas R. ;
Dery, Patrick ;
Mechaqrane, Abdellah ;
Bourbonnais, Martin ;
Meloche, Philippe ;
Izquierdo, Ricardo .
SOLAR ENERGY, 2023, 264
[50]   An experimental study on liquid regeneration process of a liquid desiccant air conditioning system (LDACs) based on vacuum membrane distillation [J].
Zhou, Junming ;
Wang, Faming ;
Noor, Nuruzzaman ;
Zhang, Xiaosong .
ENERGY, 2020, 194