Performance of combined ozonation, coagulation and ceramic membrane process for water reclamation: Effects and mechanism of ozonation on virus coagulation

被引:31
作者
Im, Dongbum [1 ]
Nakada, Norihide [1 ]
Fukuma, Yasuyuki [1 ]
Kato, Yasuhiro [2 ]
Tanaka, Hiroaki [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Res Ctr Environm Qual Management, 1-2 Yumihruna, Otsu, Shiga 5200811, Japan
[2] Metawater Co Ltd, 7 Yawatakaigandori, Ichihara, Chiba 2908511, Japan
基金
日本科学技术振兴机构;
关键词
Ozonation; Coagulation; Ceramic membrane; Virus removal; Disinfection by-product; EFFLUENT ORGANIC-MATTER; IN-SITU OZONATION; WASTE-WATER; DRINKING-WATER; PRE-OZONATION; ULTRAFILTRATION MEMBRANE; FOULING MITIGATION; OZONE DISINFECTION; SECONDARY EFFLUENT; TREATMENT-PLANT;
D O I
10.1016/j.seppur.2017.10.044
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
We investigated virus removal and the formation of disinfection by-products by a combined ozonation, coagulation, and ceramic membrane filtration process (O-3 + PACl + CMF) for water reclamation. Pilotscale continuous operation used secondary effluent as test water, and virus removal performance was tested using F-specific bacteriophage MS2. The rate of increase of transmembrane pressure decreased from 29 to 1 kPa/d with increasing ozone dosage from 0 to 6 mg/L. Ozonation reduced reversible fouling, and residual 03 reduced irreversible fouling. Ozonation increased MS2 removal from 2.1- to 6.8-log with increasing specific ozone dosage from 0.16 to 1.29 mg-O-3/mg-C. In PACT + CMF, however, MS2 removal decreased from 8.4- to 6.7-log. Lab scale batch experiments revealed that increasing ozone dosage tended to inhibit MS2 coagulation. The inhibition was attributed to the negative effect of ozonation on particle destabilization, making it harder for the coagulant to neutralize surface charge in ozonated water. The formation of polar compounds such as formaldehyde during ozonation seems to increase negative charge. Although ozonation formed small amounts of N-nitrosodimethylamine (NDMA), it reduced their formation potential, possibly reducing the final concentration of NDMA in reclaimed water. Therefore, O-3 + PACl + CMF not only improved operational performance, but also produced reclaimed water with reduced public health risks associated with viruses and NDMA.
引用
收藏
页码:429 / 434
页数:6
相关论文
共 42 条
[1]  
[Anonymous], 1995, ISO 10705-1
[2]   Removal of MS2, Qβ and GA bacteriophages during drinking water treatment at pilot scale [J].
Boudaud, Nicolas ;
Machinal, Claire ;
David, Fabienne ;
Bourdonnec, Armelle Freval-Le ;
Jossent, Jerome ;
Bakanga, Fanny ;
Arnal, Charlotte ;
Jaffrezic, Marie Pierre ;
Oberti, Sandrine ;
Gantzer, Christophe .
WATER RESEARCH, 2012, 46 (08) :2651-2664
[3]   Formaldehyde formation during ozonation of drinking [J].
Can, ZS ;
Gurol, M .
OZONE-SCIENCE & ENGINEERING, 2003, 25 (01) :41-51
[4]   The fouling of microfiltration membranes by NOM after coagulation treatment [J].
Carroll, T ;
King, S ;
Gray, SR ;
Bolto, BA ;
Booker, NA .
WATER RESEARCH, 2000, 34 (11) :2861-2868
[5]  
Carstens E.B., 2012, Virus taxonomy: classification and nomenclature of viruses: Ninth Report of the International Committee on Taxonomy of Viruses
[6]  
CDPH, 2009, REG REL REC WAT
[7]   Effect of ozone and permanganate on algae coagulation removal - Pilot and bench scale tests [J].
Chen, Jen-Jeng ;
Yeh, Hsuan-Hsien ;
Tseng, I-Cheng .
CHEMOSPHERE, 2009, 74 (06) :840-846
[8]   Effects of pre-ozonation on the ultrafiltration of different natural organic matter (NOM) fractions: Membrane fouling mitigation, prediction and mechanism [J].
Cheng, Xiaoxiang ;
Liang, Heng ;
Ding, An ;
Qu, Fangshu ;
Shao, Senlin ;
Liu, Bin ;
Wang, Hui ;
Wu, Daoji ;
Li, Guibai .
JOURNAL OF MEMBRANE SCIENCE, 2016, 505 :15-25
[9]   Towards reducing DBP formation potential of drinking water by favouring direct ozone over hydroxyl radical reactions during ozonation [J].
De Vera, Glen Andrew ;
Stalter, Daniel ;
Gernjak, Wolfgang ;
Weinberg, Howard S. ;
Keller, Jurg ;
Jose Farre, Maria .
WATER RESEARCH, 2015, 87 :49-58
[10]  
EDWARDS M, 1992, J AM WATER WORKS ASS, V84, P56