Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index

被引:91
作者
Broch, O. [1 ]
Bein, B. [1 ]
Gruenewald, M. [1 ]
Hoecker, J. [1 ]
Schoettler, J. [2 ]
Meybohm, P. [1 ]
Steinfath, M. [1 ]
Renner, J. [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, D-24105 Kiel, Germany
关键词
WAVE-FORM AMPLITUDE; MECHANICALLY VENTILATED PATIENTS; PULSE PRESSURE VARIATION; STROKE VOLUME VARIATIONS; ARTERIAL BLOOD-PRESSURE; CENTRAL VENOUS-PRESSURE; RESPIRATORY VARIATIONS; SURGERY; PLETHYSMOGRAM; CHALLENGE;
D O I
10.1111/j.1399-6576.2011.02435.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Respiratory variations in plethysmographic waveform amplitudes derived from pulse oximetry are believed to predict fluid responsiveness. The non-invasive pleth variability index (PVI) is a variable based on the calculation of changes in the perfusion index (PI). The aim of the following study was to examine whether the predictive power of PVI depends on different values of PI. Methods: Eighty-one patients undergoing elective coronary artery surgery were studied before operation: at baseline after induction of anaesthesia and during passive leg raising (PLR). Each patient was monitored with central venous pressure (CVP), the PiCCO monitor and the non-invasive Masimo monitoring system. Stroke volume index by transpulmonary thermodilution (SVI(TPTD)), pulse pressure variation (PPV), stroke volume variation (SVV) and systemic vascular resistance index (SVRI) were measured using the PiCCO monitoring system. PI and PVI were obtained by pulse oximetry. Results: Responders were defined to increase their SVI(TPTD) > 15% after PLR. The highest area under the curve (AUC) was found for PPV (AUC: 0.83, P<0.0001) and SVV (AUC: 0.72, P=0.002), in contrast to PVI (AUC: 0.60, P=0.11) and CVP (AUC: 0.60, P=0.13). The accuracy of PVI to predict fluid responsiveness was improved on analysing patients with higher PI values. PI of about 4% (n=45) achieved statistical significance (AUC: 0.72, P=0.01). Conclusion: The PVI was not able to predict fluid responsiveness with sufficient accuracy. In patients with higher perfusion states, the PVI improved its ability to predict haemodynamic changes, strongly suggesting a relevant influence of the PI on the PVI.
引用
收藏
页码:686 / 693
页数:8
相关论文
共 33 条
[31]   The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform [J].
Shelley K.H. ;
Awad A.A. ;
Stout R.G. ;
Silverman D.G. .
J. Clin. Monit. Comput., 2006, 2 (81-87) :81-87
[32]   Non-invasive prediction of fluid responsiveness during major hepatic surgery [J].
Solus-Biguenet, H. ;
Fleyfel, M. ;
Tavernier, B. ;
Kipnis, E. ;
Onimus, J. ;
Robin, E. ;
Lebuffe, G. ;
Decoene, C. ;
Pruvot, F. R. ;
Vallet, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (06) :808-816
[33]   Fluid challenge revisited [J].
Vincent, JL ;
Weil, MH .
CRITICAL CARE MEDICINE, 2006, 34 (05) :1333-1337