Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index

被引:91
作者
Broch, O. [1 ]
Bein, B. [1 ]
Gruenewald, M. [1 ]
Hoecker, J. [1 ]
Schoettler, J. [2 ]
Meybohm, P. [1 ]
Steinfath, M. [1 ]
Renner, J. [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, D-24105 Kiel, Germany
关键词
WAVE-FORM AMPLITUDE; MECHANICALLY VENTILATED PATIENTS; PULSE PRESSURE VARIATION; STROKE VOLUME VARIATIONS; ARTERIAL BLOOD-PRESSURE; CENTRAL VENOUS-PRESSURE; RESPIRATORY VARIATIONS; SURGERY; PLETHYSMOGRAM; CHALLENGE;
D O I
10.1111/j.1399-6576.2011.02435.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Respiratory variations in plethysmographic waveform amplitudes derived from pulse oximetry are believed to predict fluid responsiveness. The non-invasive pleth variability index (PVI) is a variable based on the calculation of changes in the perfusion index (PI). The aim of the following study was to examine whether the predictive power of PVI depends on different values of PI. Methods: Eighty-one patients undergoing elective coronary artery surgery were studied before operation: at baseline after induction of anaesthesia and during passive leg raising (PLR). Each patient was monitored with central venous pressure (CVP), the PiCCO monitor and the non-invasive Masimo monitoring system. Stroke volume index by transpulmonary thermodilution (SVI(TPTD)), pulse pressure variation (PPV), stroke volume variation (SVV) and systemic vascular resistance index (SVRI) were measured using the PiCCO monitoring system. PI and PVI were obtained by pulse oximetry. Results: Responders were defined to increase their SVI(TPTD) > 15% after PLR. The highest area under the curve (AUC) was found for PPV (AUC: 0.83, P<0.0001) and SVV (AUC: 0.72, P=0.002), in contrast to PVI (AUC: 0.60, P=0.11) and CVP (AUC: 0.60, P=0.13). The accuracy of PVI to predict fluid responsiveness was improved on analysing patients with higher PI values. PI of about 4% (n=45) achieved statistical significance (AUC: 0.72, P=0.01). Conclusion: The PVI was not able to predict fluid responsiveness with sufficient accuracy. In patients with higher perfusion states, the PVI improved its ability to predict haemodynamic changes, strongly suggesting a relevant influence of the PI on the PVI.
引用
收藏
页码:686 / 693
页数:8
相关论文
共 33 条
[1]  
Awad AA, 2001, ANESTH ANALG, V92, P1483
[2]   How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in coronary artery bypass graft patients? [J].
Awad, AA ;
Ghobashy, MAM ;
Stout, RG ;
Silverman, DG ;
Shelley, KH .
ANESTHESIA AND ANALGESIA, 2001, 93 (06) :1466-1471
[3]   Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs [J].
Berkenstadt, H ;
Friedman, Z ;
Preisman, S ;
Keidan, I ;
Livingstone, D ;
Perel, A .
BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (06) :721-726
[4]   Changes in central venous pressure and pulmonary capillary wedge pressure do not indicate changes in right and left heart volume in patients undergoing coronary artery bypass surgery [J].
Buhre, W ;
Weyland, A ;
Schorn, B ;
Scholz, M ;
Kazmaier, S ;
Hoeft, A ;
Sonntag, H .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (01) :11-17
[5]   Monitoring of peri-operative fluid administration by individualized goal-directed therapy [J].
Bundgaard-Nielsen, M. ;
Holte, K. ;
Secher, N. H. ;
Kehlet, H. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (03) :331-340
[6]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[7]   Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia [J].
Cannesson, M. ;
Desebbe, O. ;
Hachemi, M. ;
Jacques, D. ;
Bastien, O. ;
Lehot, J. -J .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (03) :245-251
[8]   Does the pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? [J].
Cannesson, Maxime ;
Delannoy, Bertrand ;
Morand, Antoine ;
Rosamel, Pascal ;
Attof, Yassin ;
Bastien, Olivier ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1189-1194
[9]   Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room [J].
Cannesson, Maxime ;
Attof, Yassin ;
Rosamel, Pascal ;
Desebbe, Olivier ;
Joseph, Pierre ;
Metton, Olivier ;
Bastien, Olivier ;
Lehot, Jean-Jacques .
ANESTHESIOLOGY, 2007, 106 (06) :1105-1111
[10]   Pulse pressure variations to predict fluid responsiveness: influence of tidal volume [J].
De Backer, D ;
Heenen, S ;
Piagnerelli, M ;
Koch, M ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (04) :517-523