Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: An in vitro study

被引:14
作者
Kang, Seen-Young [1 ]
Park, Jung-Hyun [1 ]
Kim, Ji-Hwan [1 ]
Kim, Woong-Chul [1 ]
机构
[1] Korea Univ, Coll Hlth Sci, Dept Dent Lab Sci & Engn, 145 Anam Ro, Seoul 136712, South Korea
关键词
Chairside CAD/CAM; Ceramic; Superimposition; Three-dimensional analysis; Trueness; MARGINAL FIT; MECHANICAL-PROPERTIES; INTERNAL ADAPTATION; SURFACE-ROUGHNESS; CAD/CAM; RESIN; ACCURACY; STRENGTH; CEMENT; MICROSTRUCTURE;
D O I
10.1016/j.jpor.2019.06.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study analyzed the trueness of polymer-infiltrated ceramic and glass ceramic crowns manufactured using the chairside computer-aided design/manufacturing (CAD/CAM) system. Methods: The master model designs crowns using a CAD program after acquiring a digital impression with an intraoral scanner. Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS) were used to manufacture 10 crowns each (total: 30 crowns), using the chairside CAD/CAM system (inLab MC XL). Trueness was evaluated by superimposing the CAD data on the scan data using a three-dimensional program. The Kruskal-Wallis H test, a nonparametric test, and the Mann-Whitney U test were performed by applying the significance level (0.05/3=0.016), which was adjusted by post-analysis Bonferroni testing. Results: There was a significant difference in the trueness between the samples (p < 0.05). However, there was no statistically significant difference in the outer surface trueness between the samples (p> 0.05). Conclusions: These findings show that the milling accuracy of VE is better than that of VS and IPS. (C) 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 39 条
[1]   3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08) :610-617
[2]  
[Anonymous], 572511997 DIN ISO
[3]  
[Anonymous], 128362012 DIN ISO
[4]  
Association AD, 2019, GUID DENT MAT DEV, P1970
[5]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[6]   Clinical fit of Procera AllCeram crowns [J].
Boening, KW ;
Wolf, BH ;
Schmidt, AE ;
Kästner, K ;
Walter, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) :419-424
[7]   A 3-DIMENSIONAL ACCURACY ANALYSIS OF CHAIRSIDE CAD/CAM MILLING PROCESSES [J].
Bosch, Gabriel ;
Ender, Andreas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) :1425-1431
[8]   Machinability of CAD-CAM materials [J].
Chavali, Ramakiran ;
Nejat, Amir H. ;
Lawson, Nathaniel C. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) :194-199
[9]   In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation [J].
Coldea, Andrea ;
Swain, Michael V. ;
Thiel, Norbert .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 26 :34-42
[10]   Mechanical properties of polymer-infiltrated-ceramic-network materials [J].
Coldea, Andrea ;
Swain, Michael V. ;
Thiel, Norbert .
DENTAL MATERIALS, 2013, 29 (04) :419-426