An investigation of statistical power for continuous arterial spin labeling imaging at 1.5 T

被引:20
作者
Asllani, Iris [1 ]
Borogovac, Ajna [5 ]
Wright, Clinton [4 ]
Sacco, Ralph [3 ,4 ]
Brown, Truman R. [1 ,5 ]
Zarahn, Eric [2 ]
机构
[1] Columbia Univ, Columbia Univ Coll Phys & Surg, Dept Radiol, New York, NY 10032 USA
[2] Columbia Univ, Columbia Univ Coll Phys & Surg, Dept Psychiat, New York, NY 10032 USA
[3] Columbia Univ, Columbia Univ Coll Phys & Surg, Dept Neurol, New York, NY 10032 USA
[4] Columbia Univ, Columbia Univ Coll Phys & Surg, Dept Epidemiol, New York, NY 10032 USA
[5] Columbia Univ, Columbia Univ Coll Phys & Surg, Dept Biomed Engn, New York, NY 10032 USA
关键词
ASL; CBF; fMRI; statistical power; intersubject variance; intrasubject variance;
D O I
10.1016/j.neuroimage.2007.10.015
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Variance estimates can be used in conjunction with scientifically meaningful effect sizes to design experiments with type It error control. Here we present estimates of intra- and inter-subject variances for region of interest (1101) from resting cerebral blood flow (CBF) maps obtained using whole brain, spin echo echoplanar (SE-EPI) continuous arterial spin labeling (CASL) imaging on 52 elderly subjects (age=70.5 +/- 7.9 years, 29 males). There was substantial intrasubject systematic variability in CBF of gray matter ROIs corresponding to a range of standard deviations= [39-168] (ml/(100 g min)). This variability was mainly due to two factors: (1) an expected inverse relationship between ROI volume and intrasubject variance and (2) an increased effective post-labeling delay for more superior slices acquired later in the sequence. For example, intrasubject variance in Brodmann area 4 (BA 4) was similar to 8 times larger than in hippocampus, despite their similar gray matter volumes. Estimated ROI-wise power was computed for various numbers of acquired CBF images, numbers of subjects, and CBF effect sizes for two experimental designs: independent sample t-test and paired t-test. The theoretical effects of pulse sequence and field strength on general applicability of these results are discussed. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1246 / 1256
页数:11
相关论文
共 36 条
[1]   Multisection cerebral blood flow MR imaging with continuous arterial spin labeling [J].
Alsop, DC ;
Detre, JA .
RADIOLOGY, 1998, 208 (02) :410-416
[2]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[3]  
Alsop DC, 2000, ANN NEUROL, V47, P93, DOI 10.1002/1531-8249(200001)47:1<93::AID-ANA15>3.3.CO
[4]  
2-#
[5]   Abnormalities of brain function during a nonverbal theory of mind task in schizophrenia [J].
Brunet, E ;
Sarfati, Y ;
Hardy-Baylé, MC ;
Decety, J .
NEUROPSYCHOLOGIA, 2003, 41 (12) :1574-1582
[6]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[7]   Measures of brain morphology and infarction in the framingham heart study: establishing what is normal [J].
DeCarli, C ;
Massaro, J ;
Harvey, D ;
Hald, J ;
Tullberg, M ;
Au, R ;
Beiser, A ;
D'Agostino, R ;
Wolf, PA .
NEUROBIOLOGY OF AGING, 2005, 26 (04) :491-510
[8]   Thalamic infarctions cause side-specific suppression of vestibular cortex activations [J].
Dieterich, M ;
Bartenstein, P ;
Spiegel, S ;
Bense, S ;
Schwaiger, M ;
Brandt, T .
BRAIN, 2005, 128 :2052-2067
[9]   An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation [J].
Donahue, Manus J. ;
Lu, Hanzhang ;
Jones, Craig K. ;
Pekar, James J. ;
van Zijl, Peter C. M. .
NMR IN BIOMEDICINE, 2006, 19 (08) :1043-1054
[10]   Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories [J].
Floyd, TF ;
Ratcliffe, SJ ;
Wang, JJ ;
Resch, B ;
Detre, JA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :649-655