Blood flow in end-to-side anastomoses

被引:80
作者
Loth, Francis [1 ,2 ]
Fischer, Paul F. [3 ]
Bassiouny, Hisham S. [4 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[3] Argonne Natl Lab, Div Math & Comp Sci, Argonne, IL 60439 USA
[4] Univ Chicago, Dept Surg, Chicago, IL 60637 USA
关键词
hemodynamics; arterial bypass graft; arteriovenous graft; transitional flow; wall shear stress;
D O I
10.1146/annurev.fluid.40.111406.102119
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Blood flow in end-to-side autogenous or prosthetic graft anastomoses is of great interest to biomedical researchers because the biomechanical force profile engendered by blood flow disturbances at such geometric transitions is thought to play a significant role in vascular remodeling and graft failure. Thus, investigators have extensively studied anastomotic blood flow patterns in relation to graft failure with the objective of enabling the design of a more optimal graft anastomotic geometry. In contrast to arterial bifurcations, surgically created anastomoses can be modified to yield a flow environment that improves graft longevity. Understanding blood flow patterns at anastomotic junctions is a challenging problem because of the highly varying and complex three-dimensional nature of the geometry that is subjected to pulsatile and, occasionally, turbulent flow.
引用
收藏
页码:367 / 393
页数:27
相关论文
共 73 条
[1]   ANASTOMOTIC INTIMAL HYPERPLASIA - MECHANICAL INJURY OR FLOW INDUCED [J].
BASSIOUNY, HS ;
WHITE, S ;
GLAGOV, S ;
CHOI, E ;
GIDDENS, DP ;
ZARINS, CK .
JOURNAL OF VASCULAR SURGERY, 1992, 15 (04) :708-717
[2]  
BINNS RL, 1989, J VASC SURG, V10, P326
[3]   Preliminary comparative study of small amplitude helical and conventional ePTFE arteriovenous shunts in pigs [J].
Caro, CG ;
Cheshire, NJ ;
Watkins, N .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) :261-266
[4]   Non-planar curvature and branching of arteries and non-planar-type flow [J].
Caro, CG ;
Doorly, DJ ;
Tarnawski, M ;
Scott, KT ;
Long, Q ;
Dumoulin, CL .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1996, 452 (1944) :185-197
[5]   Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses [J].
Chen, Jie ;
Lu, Xi-Yun ;
Wang, Wen .
JOURNAL OF BIOMECHANICS, 2006, 39 (11) :1983-1995
[6]  
CRAWSHAW HM, 1980, ARCH SURG-CHICAGO, V115, P1280
[7]   FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION [J].
DAVIES, PF .
PHYSIOLOGICAL REVIEWS, 1995, 75 (03) :519-560
[8]   VASCULAR ENDOTHELIUM RESPONDS TO FLUID SHEAR-STRESS GRADIENTS [J].
DEPAOLA, N ;
GIMBRONE, MA ;
DAVIES, PF ;
DEWEY, CF .
ARTERIOSCLEROSIS AND THROMBOSIS, 1992, 12 (11) :1254-1257
[9]   Stented artery flow patterns and their effects on the artery wall [J].
Duraiswamy, Nandim ;
Schoephoerster, Richard T. ;
Moreno, Michael R. ;
Moore, James E., Jr. .
ANNUAL REVIEW OF FLUID MECHANICS, 2007, 39 :357-382
[10]  
ECHAVE V, 1979, SURGERY, V86, P791