Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study

被引:7
作者
de Vries, L. M. [1 ]
Leening, M. J. G. [1 ,2 ,3 ]
Dijk, W. A. [4 ]
Hooijschuur, C. A. M. [4 ]
Stricker, B. H. C. [1 ]
van Hemel, N. M. [5 ]
机构
[1] Erasmus MC, Dept Epidemiol, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[3] Harvard TH Chan Sch Publ Hlth, Dept Epidemiol, Boston, MA USA
[4] Univ Groningen, Univ Med Ctr Groningen, Thorax Ctr, Groningen, Netherlands
[5] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
关键词
Pacemaker longevity; Pacemaker follow-up; Generator replacement; Pacemaker infection; Pacemaker recall; DEVICE; GENERATOR; LONGEVITY; REGISTRY; COMPLICATIONS; MULTICENTER; UPDATE; COHORT;
D O I
10.1007/s12471-017-1024-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims After decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker. Methods We reviewed data collected between 1984 and 2006 in the first national Dutch pacemaker registry. This registry covered 96% of all generators implanted. We analysed the time of and reason for explantation of pacemaker generators. A 7-year follow-up interval after first implantation and following replacements was used to analyse changes over time. Results During 22 years of data collection, nearly 97,000 first pacemaker generators were implanted. A total of 27,937 (22.4%) generators were explanted within a mean of 6.3 (standard deviation 3.3) years. Reasons for approximately 60% of these explantations were ` end of life' of the pacemaker generator or elective system change. Complications or failures such as infections and recalls accounted for approximately 20% of the explantations. For the remaining 20%, the reasons for explantation had not been registered. Conclusion Despite progress in technology, a substantial proportion of pacemaker generators is explanted before its expected service time, with one in five generators being replaced due to technical failures, infections or other complications. Furthermore, the time interval between pacemaker implantation and explantation due to normal 'end of life' (battery EOL) decreased. Infections continue to rank highly as a cause for pacing system replacement, despite all current preventive measures.
引用
收藏
页码:581 / 591
页数:11
相关论文
共 20 条
  • [1] Post-mortem evaluation of 415 pacemakers: in situ measurements and bench tests
    Bartsch, C
    Irnich, W
    Junge, M
    Stertmann, WA
    Risse, M
    Weiler, G
    [J]. EUROPACE, 2005, 7 (02): : 175 - 180
  • [2] Optimizing Pacemaker Longevity with Pacing Mode and Settings Programming: Results from a Pacemaker Multicenter Registry
    Benkemoun, Henri
    Sacrez, Jean
    Lagrange, Philippe
    Amie, Alain
    Prakash, Atul
    Himmrich, Ewald
    Aime, Ezio
    Mairesse, Georges H.
    Guenon, Christine
    Sbragia, Pascal
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (04): : 403 - 408
  • [3] Utilisation of cardiac pacemakers over a 20-year period: Results from a nationwide pacemaker registry
    de Vries, L. M.
    Dijk, W. A.
    Hooijschuur, C. A. M.
    Leening, M. J. G.
    Stricker, B. H. C.
    van Hemel, N. M.
    [J]. NETHERLANDS HEART JOURNAL, 2017, 25 (01) : 47 - 55
  • [4] Validation of the Netherlands pacemaker patient registry
    Dijk, WA
    Kingma, T
    Hooijschuur, CAM
    Dassen, WRM
    Hoorntje, JCA
    van Gelder, LM
    [J]. COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 653 - 656
  • [5] Dijk WA, 1989, COMPUT CARDIOL, V293, DOI [10.1109/CIC.1989.130547, DOI 10.1109/CIC.1989.130547]
  • [6] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices
    Eyal, Allon
    Roguin, Ariel
    [J]. CIRCULATION, 2015, 132 (14) : E176 - E178
  • [7] Feasibility and initial results of an Internet-based pacemaker and ICD pulse generator and lead registry
    Hauser, R
    Hayes, D
    Parsonnet, V
    Furman, S
    Epstein, A
    Hayes, J
    Saksena, S
    Irwin, M
    Almquist, A
    Cannom, D
    Gross, J
    Kallinen, L
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (01): : 82 - 87
  • [8] Clinical experience with pacemaker pulse generators and transvenous leads: An 8-year prospective multicenter study
    Hauser, Robert G.
    Hayes, David L.
    Kallinen, Linda M.
    Cannom, David S.
    Epstein, Andrew E.
    Almquist, Adrian K.
    Song, Susan L.
    Tyers, G. Frank O.
    Vlay, Stephen C.
    Irwin, Marleen
    [J]. HEART RHYTHM, 2007, 4 (02) : 154 - 160
  • [9] The Rotterdam Study: 2016 objectives and design update
    Hofman, Albert
    Brusselle, Guy G. O.
    Murad, Sarwa Darwish
    van Duijn, Cornelia M.
    Franco, Oscar H.
    Goedegebure, Andre
    Ikram, M. Arfan
    Klaver, Caroline C. W.
    Nijsten, Tamar E. C.
    Peeters, Robin P.
    Stricker, Bruno H. Ch.
    Tiemeier, Henning W.
    Uitterlinden, Andre G.
    Vernooij, Meike W.
    [J]. EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2015, 30 (08) : 661 - 708
  • [10] Hooijschuur CAM, 2008, NETH HEART J, V16, P9