A comprehensive analysis of the moist air transonic flow in a nozzle with a very low expansion rate

被引:7
作者
Wisniewski, Piotr [1 ]
Dykas, Slawomir [1 ]
Majkut, Miroslaw [1 ]
Smolka, Krysian [1 ]
Nocon, Michal [2 ]
Wittmann, Tim [3 ]
Friedrichs, Jens [3 ]
机构
[1] Silesian Tech Univ, Dept Power Engn & Turbomachinery, Gliwice, Poland
[2] Mashinada Nocon Sj, Gliwice, Poland
[3] Braunschweig Univ Technol, Inst Jet Prop & Turbomachinery, Braunschweig, Germany
关键词
Moist air; Transonic flow; CFD; Condensation; Multi -phase flows; WET STEAM FLOW; LIFT; DRAG;
D O I
10.1016/j.applthermaleng.2022.119185
中图分类号
O414.1 [热力学];
学科分类号
摘要
Inevitable and undesirable as it is, phase transition has a significant impact on the fluid flow efficiency in many energy processes. This paper deals with the impact of water vapour condensation and liquid water evaporation in the moist air expansion in a nozzle with a low expansion rate. The presented comprehensive analysis includes a numerical study supported by analytical and experimental research. The experimental study concerning mea-surements of atmospheric air transonic flows was carried out using an in-house experimental test rig. A nozzle with a low expansion rate of over dot(P) asymptotic to 1000s(-1) was investigated experimentally at different inlet air relative humidity values included in the range of 25 to 51 %. The nozzle was measured for supersonic outlet conditions, as well as with elevated back pressure (78 kPa). The technique of Schlieren photography and static pressure measurement on the nozzle wall were used for qualitative identification of both condensation and shock waves. The presented numerical modelling was conducted using commercial computational fluid dynamics software extended with an in-house condensation model. The code was validated against experimental data and data available in the literature. The analysis of the flow in the nozzle with a very low expansion rate revealed very interesting structures of pressure waves. The impact of relative air humidity on the condensation process and the interaction of the condensation wave with aerodynamic oblique as well as normal shock waves were investigated. It is observed that the higher the air relative humidity value, the more difficult it is to identify aerodynamically induced oblique shock waves in the flow. Finally, considering that the efficiency drop induced by the phase change can reach up to 10 %, the impact of condensation on the expansion process efficiency is presented.
引用
收藏
页数:13
相关论文
共 33 条
  • [1] Adam S., 1996, NUMERISCHE EXPERIMEN
  • [2] [Anonymous], 2021, ANSYS Fluent Theory Guide
  • [3] Two semi-analytical approaches for solving condensation shocks in supersonic nozzle flows
    Bolanos-Acosta, A. F.
    Restrepo, J. C.
    Simoes-Moreira, J. R.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 173
  • [4] Cook P. H., 1979, AR138 AGARD
  • [5] THE 1993 IGTI SCHOLAR LECTURE - LOSS MECHANISMS IN TURBOMACHINES
    DENTON, JD
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1993, 115 (04): : 621 - 656
  • [6] Dohrmann U., 1989, DISSERTATION
  • [7] Experimental Research on Wet Steam Flow With Shock Wave
    Dykas, S.
    Majkut, M.
    Smolka, K.
    Strozik, M.
    [J]. EXPERIMENTAL HEAT TRANSFER, 2015, 28 (05) : 417 - 429
  • [8] Influence of Air Humidity on Transonic Flows with Weak Shock Waves
    Dykas, Slawomir
    Majkut, Miroslaw
    Smolka, Krystian
    [J]. JOURNAL OF THERMAL SCIENCE, 2020, 29 (06) : 1551 - 1557
  • [9] Analysis of the steam condensing flow in a linear blade cascade
    Dykas, Slawomir
    Majkut, Miroslaw
    Smolka, Krystian
    Strozik, Michal
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2018, 232 (05) : 501 - 514
  • [10] Study of the wet steam flow in the blade tip rotor linear blade cascade
    Dykas, Slawomir
    Majkut, Miroslaw
    Smolka, Krystian
    Strozik, Michal
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 120 : 9 - 17