Evaluation of the agreement of optical biometry and Scheimpflug corneal topography with different axial lengths

被引:1
作者
Gurlevik, U. [1 ]
Yasar, E. [1 ]
机构
[1] Aksaray Univ, Ophthalmol Dept, Fac Med, Aksaray, Turkey
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2021年 / 44卷 / 10期
关键词
Optical Biometry; Scheimpflug Corneal Topography; Central Corneal Thickness; Anterior Chamber Depth; White to White Distance; INTRAOCULAR-LENS POWER; REPEATABILITY;
D O I
10.1016/j.jfo.2021.06.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - To compare anterior segment parameters evaluated with optical low coherence reflectometry and combined Scheimpflug-Placido disc topography in eyes with different axial lengths. Methods. - Deux cent quatre patients were divided into 3 groups according to their axial lengths. Central corneal thickness (CCT), anterior chamber depth (AD), mean keratometry value (K mean) and white-to-white distances (WTW) obtained from both devices were compared. All measurements were performed 3 times and averaged. Results. - In group 1, a significant difference was detected between the two devices for CCT, WTW and Kmean measurements (P < 0.001, P < 0.001, p:0.005 respectively). In group 2, a significant difference was detected between the two devices for WTW measurement (P < 0.001). In group 3, a significant difference was detected between the two devices for CCT and WTW measurement (P < 0.001, P < 0.001 respectively). In the Bland-Altman analysis, there was no match for Kmean obtained with both devices in group 1. In group 2, there was no agreement for AD obtained with both devices. In group 3, there was no match for AD, WTW or Kmean values obtained with both devices.
引用
收藏
页码:1576 / 1583
页数:8
相关论文
共 26 条
  • [1] Bayhan HA, 2013, GLOKOM KATARAKT, V8
  • [2] Phakic intraocular lenses
    Chang, DH
    Davis, EA
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (01) : 99 - 104
  • [3] Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: Repeatability and agreement
    Chen, Wuhe
    McAlinden, Colm
    Pesudovs, Konrad
    Wang, Qinmei
    Lu, Fan
    Feng, Yifan
    Chen, Jie
    Huang, Jinhai
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09) : 1626 - 1632
  • [4] Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients
    Chen, Yao
    Xia, Xiaobo
    [J]. BMC OPHTHALMOLOGY, 2016, 16
  • [5] A comparative study of the performance of different corneal topographers on children with respect to orthokeratology practice
    Chui, WS
    Cho, P
    [J]. OPTOMETRY AND VISION SCIENCE, 2005, 82 (05) : 420 - 427
  • [6] Contralateral Eye Study of Corneal Collagen Cross-linking With Riboflavin and UVA Irradiation in Patients With Keratoconus
    Coskunseven, Efekan
    Jankov, Mirko R., II
    Hafezi, Farhad
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (04) : 371 - 376
  • [7] Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles
    Dabasia, Priya L.
    Edgar, David F.
    Murdoch, Ian E.
    Lawrenson, John G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (06) : 3929 - 3935
  • [8] Devereux JG, 2000, ARCH OPHTHALMOL-CHIC, V118
  • [9] Gursoy A, 2011, EUR J OPHTHALMOL, V21
  • [10] Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    Huang, Jinhai
    Pesudovs, Konrad
    Wen, Daizong
    Chen, Shihao
    Wright, Thomas
    Wang, Xiaoyu
    Li, Yini
    Wang, Qinmei
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 341 - 348