A novel, yet simple MLC-based 3D-crossfire technique for spatially fractionated GRID therapy treatment of deep-seated bulky tumors

被引:20
作者
Pokhrel, Damodar [1 ]
Halfman, Matthew [1 ]
Sanford, Lana [1 ]
Chen, Quan [1 ]
Kudrimoti, Mahesh [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Med Phys Grad Program, Lexington, KY 40506 USA
关键词
3D-MLC Crossfire; Bulky-tumors; cerrobend GRID-block; dose-escalation; RADIATION-THERAPY; DOSE CALCULATION; RADIOTHERAPY; IRRADIATION; ADVANTAGE;
D O I
10.1002/acm2.12826
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Treating deep-seated bulky tumors with traditional single-field Cerrobend GRID-blocks has many limitations such as suboptimal target coverage and excessive skin toxicity. Heavy traditional GRID-blocks are a concern for patient safety at various gantry-angles and dosimetric detail is not always available without a GRID template in user's treatment planning system. Herein, we propose a simple, yet clinically useful multileaf collimator (MLC)-based three-dimensional (3D)-crossfire technique to provide sufficient target coverage, reduce skin dose, and potentially escalate tumor dose to deep-seated bulky tumors. Materials/methods Thirteen patients (multiple sites) who underwent conventional single-field cerrobend GRID-block therapy (maximum, 15 Gy in 1 fraction) were re-planned using an MLC-based 3D-crossfire method. Gross tumor volume (GTV) was used to generate a lattice pattern of 10 mm diameter and 20 mm center-to-center mimicking conventional GRID-block using an in-house MATLAB program. For the same prescription, MLC-based 3D-crossfire grid plans were generated using 6-gantry positions (clockwise) at 60 degrees spacing (210 degrees, 270 degrees, 330 degrees, 30 degrees, 90 degrees, 150 degrees, therefore, each gantry angle associated with a complement angle at 180 degrees apart) with differentially-weighted 6 or 18 MV beams in Eclipse. For each gantry, standard Millenium120 (Varian) 5 mm MLC leaves were fit to the grid-pattern with 90 degrees collimator rotation, so that the tunneling dose distribution was achieved. Acuros-based dose was calculated for heterogeneity corrections. Dosimetric parameters evaluated include: mean GTV dose, GTV dose heterogeneities (peak-to-valley dose ratio, PVDR), skin dose and dose to other adjacent critical structures. Additionally, planning time and delivery efficiency was recorded. With 3D-MLC, dose escalation up to 23 Gy was simulated for all patient's plans. Results All 3D-MLC crossfire GRID plans exhibited excellent target coverage with mean GTV dose of 13.4 +/- 0.5 Gy (range: 12.43-14.24 Gy) and mean PVDR of 2.0 +/- 0.3 (range: 1.7-2.4). Maximal and dose to 5 cc of skin were 9.7 +/- 2.7 Gy (range: 5.4-14.0 Gy) and 6.3 +/- 1.8 Gy (range: 4.1-11.1 Gy), on average respectively. Three-dimensional-MLC treatment planning time was about an hour or less. Compared to traditional GRID-block, average beam on time was 20% less, while providing similar overall treatment time. With 3D-MLC plans, tumor dose can be escalated up to 23 Gy while respecting skin dose tolerances. Conclusion The simple MLC-based 3D-crossfire GRID-therapy technique resulted in enhanced target coverage for de-bulking deep-seated bulky tumors, reduced skin toxicity and spare adjacent critical structures. This simple MLC-based approach can be easily adopted by any radiotherapy center. It provides detailed dosimetry and a safe and effective treatment by eliminating the heavy physical GRID-block and could potentially provide same day treatment. Prospective clinical trial with higher tumor-dose to bulky deep-seated tumors is anticipated.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 35 条
[1]   Feasibility of a simple method of hybrid collimation for megavoltage grid therapy [J].
Almendral, Pedro ;
Mancha, Pedro J. ;
Roberto, Daniel .
MEDICAL PHYSICS, 2013, 40 (05)
[2]  
[Anonymous], 2018, ECLIPSE PHOTON ELECT
[3]  
Asur R, 2013, RADIAT RES, V177, P751
[4]   High dose bystander effects in spatially fractionated radiation therapy [J].
Asur, Rajalakshmi ;
Butterworth, Karl T. ;
Penagaricano, Jose A. ;
Prise, Kevin M. ;
Griffin, Robert J. .
CANCER LETTERS, 2015, 356 (01) :52-57
[5]  
Chen Q, 2019, MED PHYS, V46, pE278
[6]   A treatment planning approach to spatially fractionated megavoltage grid therapy for bulky lung cancer [J].
Costlow, Heather N. ;
Zhang, Hualin ;
Das, Indra J. .
MEDICAL DOSIMETRY, 2014, 39 (03) :218-226
[7]   VASCULAR ENDOTHELIUM AS THE VULNERABLE ELEMENT IN TUMORS [J].
DENEKAMP, J .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (04) :217-225
[8]   Tumor response to radiotherapy regulated by endothelial cell apoptosis [J].
Garcia-Barros, M ;
Paris, F ;
Cordon-Cardo, C ;
Lyden, D ;
Rafii, S ;
Haimovitz-Friedman, A ;
Fuks, Z ;
Kolesnick, R .
SCIENCE, 2003, 300 (5622) :1155-1159
[9]   Feasibility of delivering grid therapy using a multileaf collimator [J].
Ha, JK ;
Zhang, GW ;
Naqvi, SA ;
Regine, WF ;
Yu, CX .
MEDICAL PHYSICS, 2006, 33 (01) :76-82
[10]   Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation [J].
Handsfield, Lydia L. ;
Jones, Ryan ;
Wilson, David D. ;
Siebers, Jeffery V. ;
Read, Paul W. ;
Chen, Quan .
MEDICAL PHYSICS, 2014, 41 (10)