Two-layer co-optimization method for a distributed energy system combining multiple energy storages

被引:46
作者
Guo, Jiacheng [1 ]
Liu, Zhijian [1 ]
Wu, Xuan [2 ]
Wu, Di [1 ]
Zhang, Shicong [3 ]
Yang, Xinyan [3 ]
Ge, Hua [4 ]
Zhang, Peiwen [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Dept Power Engn, Baoding 071003, Peoples R China
[2] North China Elect Power Univ, Dept Comp, Baoding 071003, Peoples R China
[3] China Acad Bldg Res, Inst Bldg Environm & Energy, Beijing 100013, Peoples R China
[4] Concordia Univ, Montreal, PQ, Canada
基金
国家重点研发计划; 北京市自然科学基金;
关键词
Distributed energy system; Power-to-heat/cold; Multiple energy storage systems; Two-layer co-optimization method; Nearly zero-energy community; DESIGN OPTIMIZATION; POWER-SYSTEM; PERFORMANCE; OPERATION; HEAT; BUILDINGS;
D O I
10.1016/j.apenergy.2022.119486
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the rapid development of nearly zero-energy buildings, the establishment of a nearly zero-energy community composed of concentrated and contiguous nearly zero-energy buildings constitutes the future architectural trend. However, configuration and optimization research of distributed energy systems combining multiple energy storages (DES-MESs) for the nearly zero-energy community is not sufficiently mature. Therefore, this paper initially proposed a DES-MES combining power-to-heat, power-to-cold and lithium batteries. Subsequently, a two-layer co-optimization method was proposed considering the equipment configuration in the upper layer and energy storage operating parameters in the under-layer. Based on the nearly zero-energy community, the influence of the initial parameters on the DES-MES optimization results was studied. Then, comparative research of different co-optimization methods was conducted. Finally, analysed the interactive electricity quantity, annual cost, carbon dioxide emissions, etc., of the DES-MES under the nearly zero-energy community scenario. The results indicated that the stability of the performance indicators (volatility under 5.0%) and decision variables (volatility under 30.0%) of the system were much higher than those determined with multi-parameter or multi-stage co-optimization methods. Compared to the separated production system, the primary energy consumption and carbon dioxide emissions of the DES-MES were reduced by 4.7 x 10(6) kWh (72.3%) and 1.6 x 10(6) kg (79.0%), respectively. The two-layer co-optimization method could effectively solve the problem of balancing the accuracy of the optimization results and calculation time. This paper provides a solution for the study of the system structure, operation optimization, and performance indicators of the DES-MES under the nearly zero-energy community scenario.
引用
收藏
页数:22
相关论文
共 66 条
[1]   Selection of waste-to-energy technology for distributed generation using IDOCRIW-Weighted TOPSIS method: A case study of the City of Johannesburg, South Africa [J].
Alao, Moshood Akanni ;
Popoola, Olawale M. ;
Ayodele, Temitope Rapheal .
RENEWABLE ENERGY, 2021, 178 :162-183
[2]   Enhancement of photovoltaic system performance via passive cooling: Theory versus experiment [J].
Amr, Ayman Abdel-raheim ;
Hassan, A. A. M. ;
Abdel-Salam, Mazen ;
El-Sayed, AbouHashema M. .
RENEWABLE ENERGY, 2019, 140 :88-103
[3]   The techno-economic and environmental analysis of genetic algorithm (GA) optimized cold thermal energy storage (CTES) for air-conditioning applications [J].
Barthwal, Mohit ;
Dhar, Atul ;
Powar, Satvasheel .
APPLIED ENERGY, 2021, 283
[4]   Numerical modeling and optimization of thermal stratification in solar hot water storage tanks for domestic applications: CFD study [J].
Bouhal, T. ;
Fertahi, S. ;
Agrouaz, Y. ;
El Rhafiki, T. ;
Kousksou, T. ;
Jamil, A. .
SOLAR ENERGY, 2017, 157 :441-455
[5]   Two-stage robust planning-operation co-optimization of energy hub considering precise energy storage economic model [J].
Chen, Cong ;
Sun, Hongbin ;
Shen, Xinwei ;
Guo, Ye ;
Guo, Qinglai ;
Xia, Tian .
APPLIED ENERGY, 2019, 252
[6]   Effect of load following strategies, hardware, and thermal load distribution on stand-alone hybrid CCHP systems [J].
Das, Barun K. ;
Al-Abdeli, Yasir M. ;
Kothapalli, Ganesh .
APPLIED ENERGY, 2018, 220 :735-753
[7]   Design optimization of a distributed energy system through cost and exergy assessments [J].
Di Somma, Marialaura ;
Yan, Bing ;
Bianco, Nicola ;
Graditi, Giorgio ;
Luh, Peter B. ;
Mongibello, Luigi ;
Naso, Vincenzo .
8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 :2451-2459
[8]   China's pathways to peak carbon emissions: New insights from various industrial sectors [J].
Fang, Kai ;
Li, Chenglin ;
Tang, Yiqi ;
He, Jianjian ;
Song, Junnian .
APPLIED ENERGY, 2022, 306
[9]   Sustainability analysis for the design of distributed energy systems: A multi-objective optimization approach [J].
Fonseca, Juan D. ;
Commenge, Jean-Marc ;
Camargo, Mauricio ;
Falk, Laurent ;
Gil, Ivan D. .
APPLIED ENERGY, 2021, 290 (290)
[10]   Energy, carbon and cost analysis for an innovative zero energy community design [J].
Fouad, M. M. ;
Iskander, John ;
Shihata, Lamia A. .
SOLAR ENERGY, 2020, 206 :245-255