Restoration of red blood cell volume following 2-unit red blood cell apheresis

被引:7
作者
Valeri, CR [1 ]
Ragno, G [1 ]
Srey, R [1 ]
机构
[1] Boston Univ, Sch Med, Naval Blood Res Lab, Boston, MA 02118 USA
关键词
2-unit RBC apheresis;
D O I
10.1046/j.1423-0410.2003.00333.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Blood donors who weigh at least 130 lbs (59 kg) and have a haematocrit of at least 40 V per cent can donate 2 units of blood, from which a 360-ml volume of red blood cells ( RBC) can be isolated. This study was carried out in seven healthy male blood donors to assess the restoration of the RBC volume 1 month following a 2-unit RBC apheresis procedure. Materials and Methods RBC volumes were measured prior to donation and 4 weeks after the 2-unit RBC apheresis procedure without oral iron supplementation. Results Four weeks after the removal of 2 units of RBC from the male donors not supplemented with oral iron, the RBC volume was restored to 92% of the precollection value. The 360-ml volume of RBC collected represented 12-19% of the donor's original RBC volume. Conclusions Male donors can safely donate 2 units of RBC and will restore a mean of 92% of their RBC volume within 1 month without iron supplementation.
引用
收藏
页码:85 / 87
页数:3
相关论文
共 12 条
[1]   DNA-based typing of blood groups for the management of multiply-transfused sickle cell disease patients [J].
Castilho, L ;
Rios, M ;
Bianco, C ;
Pellegerino, J ;
Alberto, FL ;
Saad, STO ;
Costa, FF .
TRANSFUSION, 2002, 42 (02) :232-238
[2]   AUTOTRANSFUSIONS OF PREVIOUSLY FROZEN BLOOD IN ELECTIVE GYNECOLOGIC SURGERY [J].
DAANE, TA ;
VALERI, CR ;
BARTON, RK .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1969, 105 (03) :394-&
[3]   IRON STORES AND IRON-ABSORPTION - EFFECTS OF REPEATED BLOOD DONATIONS [J].
GARRY, PJ ;
KOEHLER, KM ;
SIMON, TL .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (03) :611-620
[4]   Prolonged iron depletion after allogeneic X-unit RBC apheresis [J].
Högler, W ;
Mayer, W ;
Messmer, C ;
Eibl, G ;
Innhofer, P ;
Schönitzer, D ;
Nussbaumer, W .
TRANSFUSION, 2001, 41 (05) :602-605
[5]   RED-CELL COLLECTION BY APHERESIS TECHNOLOGY [J].
MEYER, D ;
BOLGIANO, DC ;
SAYERS, M ;
PRICE, T ;
BENSON, D ;
SLICHTER, SJ .
TRANSFUSION, 1993, 33 (10) :819-824
[6]  
SAWKA MN, 1992, MED SCI SPORT EXER, V24, P447
[7]   EFFECT ON CARDIOVASCULAR FUNCTION AND IRON-METABOLISM OF THE ACUTE REMOVAL OF 2 UNITS OF RED-CELLS [J].
SHERMAN, LA ;
LIPPMANN, MB ;
AHMED, P ;
BUCHHOLZ, DH .
TRANSFUSION, 1994, 34 (07) :573-577
[8]   IRON STORES IN BLOOD-DONORS [J].
SIMON, TL ;
GARRY, PJ ;
HOOPER, EM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1981, 245 (20) :2038-2043
[9]   Iron, iron everywhere but not enough to donate [J].
Simon, TL .
TRANSFUSION, 2002, 42 (06) :664-665
[10]  
SMITH KJ, 1996, PRINCIPLES TRANSFUSI, P871