ANALYSYS AND VERIFICATION OF CALIBRATION METHODS FOR FULLY POLARIMETRIC W-BAND RADIOMETER

被引:0
作者
Kim, Sung-Hyun [1 ]
Moon, Nam-Won [1 ]
Kim, Yong-Hoon [1 ]
机构
[1] Gwangju Inst Sci & Technol, Sch Informat & Mechatron, Kwangju 500712, South Korea
来源
2010 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM | 2010年
关键词
calibration; radiometer; plate grid; retardation plate; W-band; polarization;
D O I
10.1109/IGARSS.2010.5651193
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The design method of calibration standard of fully polarimetric radiometer to measure the Stokes parameters at W-band is proposed. The information of 45 in a linear and a circular polarization are calibrated using the wire grid with thin Teflon substrate and the retardation plate which was implemented by dielectric plate with grove. The calibration standards show good performance on orthogonal channel polarization mixing (-17 to -25 dB), on mixing from the orthogonal channel into the polarimetric channels (-10.1 to -6.0 dB), and on mixing between polarization channels (-3.2 to -5.8 dB).