Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: Biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns

被引:102
|
作者
Kuehne, Michael [1 ]
Suter, Yves [1 ]
Altmann, David [1 ]
Ammann, Peter [2 ]
Schaer, Beat [1 ]
Osswald, Stefan [1 ]
Sticherling, Christian [1 ]
机构
[1] Univ Basel Hosp, Div Cardiol, CH-4031 Basel, Switzerland
[2] Kantonsspital St Gallen, Div Cardiol, St Gallen, Switzerland
关键词
Catheter ablation; Cryoballoon; Myocardial injury; Paroxysmal atrial fibrillation; Pulmonary vein isolation; Troponin; CONDUCTION; RECOVERY; EFFICACY;
D O I
10.1016/j.hrthm.2010.08.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Cryoballoon ablation has emerged as a novel treatment strategy for patients with atrial fibrillation (AF). OBJECTIVE The purpose of this study was to compare pulmonary vein isolation (PVI) using cryoballoon ablation versus RF ablation with regard to myocardial injury, pulmonary vein (PV) reconnection patterns, and outcome. METHODS Fifty patients (age 59 +/- 9 years, ejection fraction 0.59 +/- 0.06, left atrial size 41 +/- 5 mm) with paroxysmal AF were studied. Twenty-five patients underwent PVI using a 28-mm cryoballoon. A control group of 25 patients underwent PVI using an open-irrigation RF ablation catheter. Myocardial injury was determined by measuring troponin T (TnT). PV reconnection patterns were studied in case of repeat procedures. RESULTS Procedure duration was 166 +/- 32 minutes in the cryoballoon group versus 197 +/- 52 minutes in the RF group (P = .014), with similar ablation times (cryoballoon: 45 minutes [interquartile range 40-52.5 minutes]; RF: 47 minutes [interquartile range 44-65 minutes], P = .17). Postprocedural TnT in the RF group was 1.29 +/- 0.41 mu g/L versus 0.76 +/- 0.55 mu g/L in the cryoballoon group (P = .002). In 12 patients who underwent repeat ablation, 74% of PV reconnection sites were inferiorly located in the cryoballoon group compared to 17% in the RF group (P = .0004). With 1.2 +/- 0.4 and 1.3 +/- 0.6 procedures per patient, 88% of patients in the cryoballoon group and 92% in the RF group were in stable sinus rhythm after follow-up of 12 +/- 3 months (P = NS). CONCLUSION Differences in the extent of myocardial injury and patterns of PV reconnection were observed between cryoballoon ablation and RF ablation of paroxysmal AF.
引用
收藏
页码:1770 / 1776
页数:7
相关论文
共 50 条
  • [31] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [32] Propensity-score-matched comparison of cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation
    Knecht, S.
    Von Felten, S.
    Conen, D.
    Vollmin, G.
    Schaer, B.
    Osswald, S.
    Sticherling, C.
    Kuhne, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 753 - 753
  • [35] Efficacy and safety of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation: A comparison with radiofrequency ablation
    Choi, Ji-Hoon
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    PLOS ONE, 2022, 17 (07):
  • [36] Procedural Parameters During Cryoballoon Ablation Predict Early Pulmonary Vein Reconnection and Atrial Fibrillation Recurrence
    Chahine, Yaacoub
    Afroze, Tanzina
    Bifulco, Savannah
    Macheret, Fima
    Abdulsalam, Nashwa
    Boyle, Patrick M.
    Akoum, Nazem W.
    CIRCULATION, 2022, 146
  • [37] Catheter ablation for paroxysmal atrial fibrillation - Segmental pulmonary vein ostial ablation versus left atrial ablation
    Oral, H
    Scharf, C
    Chugh, A
    Hall, B
    Cheung, P
    Good, E
    Veerareddy, S
    Pelosi, F
    Morady, F
    CIRCULATION, 2003, 108 (19) : 2355 - 2360
  • [38] Correlation of pulmonary vein reconnection patterns after cryoballoon and duty-cycled ablation of atrial fibrillation with the time of arrhythmia recurrence
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF ARRHYTHMIA, 2020, 36 (06) : 1051 - 1060
  • [39] Durability of pulmonary vein isolation for paroxysmal atrial fibrillation using contact force-sensing radiofrequency versus cryoballoon ablation
    Miyazawa, S.
    Fukamizu, S.
    Miyahara, D.
    Inagaki, D.
    Kawamura, I.
    Nagamine, S.
    Masuda, S.
    Hojo, R.
    Tsuchiyama, T.
    Komiyama, K.
    Shibui, T.
    Nishizaki, M.
    Sakurada, H.
    Hiraoka, M.
    EUROPEAN HEART JOURNAL, 2017, 38 : 175 - 175
  • [40] Pulmonary vein size is associated with reconnection following cryoballoon ablation of atrial fibrillation
    Giacomo Mugnai
    Federico Cecchini
    Erwin Stroker
    Gaetano Paparella
    Saverio Iacopino
    Juan Sieira
    Yves De Greef
    Luca Tomasi
    Bruna Bolzan
    Gezim Bala
    Ingrid Overeinder
    Alexandre Almorad
    Anais Gauthey
    Antonio Sorgente
    Flavio Luciano Ribichini
    Carlo de Asmundis
    Gian-Battista Chierchia
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 717 - 724