Accuracy and Reproducibility of Strain by Speckle Tracking in Pediatric Subjects with Normal Heart and Single Ventricular Physiology: A Two-Dimensional Speckle-Tracking Echocardiography and Magnetic Resonance Imaging Correlative Study

被引:100
作者
Singh, Gautam K. [1 ]
Cupps, Brian [2 ]
Pasque, Michael [2 ]
Woodard, Pamela K. [3 ]
Holland, Mark R. [4 ]
Ludomirsky, Achiau [5 ]
机构
[1] Washington Univ, Dept Pediat, Div Cardiol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Cardiac Surg, St Louis, MO 63110 USA
[3] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[4] Washington Univ, Dept Phys, St Louis, MO 63110 USA
[5] NYU, Dept Pediat, Div Cardiol, New York, NY 10016 USA
关键词
Myocardial strain; Single ventricle; Fontan procedure; Left ventricle; MYOCARDIAL SYSTOLIC STRAIN; LONGITUDINAL STRAIN; FIBER ORIENTATION; VALIDATION; TISSUE; DEFORMATION; MECHANICS; DOPPLER; CONTRACTILITY; ANISOTROPY;
D O I
10.1016/j.echo.2010.08.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial strain is a sensitive measure of ventricular systolic function. Two-dimensional speckle-tracking echocardiography (2DSE) is an angle-independent method for strain measurement but has not been validated in pediatric subjects. The aim of this study was to evaluate the accuracy and reproducibility of 2DSE-measured strain against reference tagged magnetic resonance imaging-measured strain in pediatric subjects with normal hearts and those with single ventricles (SVs) of left ventricular morphology after the Fontan procedure. Methods: Peak systolic circumferential strain and longitudinal strain (LS) in segments (n = 16) of left ventricles in age-matched and body surface area-matched 20 healthy and 12 pediatric subjects with tricuspid atresia after the Fontan procedure were measured by 2DSE and tagged magnetic resonance imaging. Average (global) and regional segmental strains measured by the two methods were compared using Spearman's and Bland-Altman analyses. Results: Global strains measured by 2DSE and tagged magnetic resonance imaging demonstrated close agreements, which were better for LS than circumferential strain and in normal left ventricles than in SVs (95% limits of agreement, +0.0% to +3.12%, -2.48% to +1.08%, -4.6% to +1.8%, and -3.6% to +1.8%, respectively). There was variability in agreement between regional strains, with wider limits in apical than in basal regions in normal left ventricles and heterogeneity in SVs. Strain values were significantly (P < .05) higher in normal left ventricles than in SVs except for basal LS, which were similar in both cohorts. The regional strains in normal left ventricles demonstrated an apicobasal magnitude gradient, whereas SVs showed heterogeneity. Reproducibility was the most robust for images obtained with frame rates between 60 and 90 frames/sec, global LS in both cohorts, and basal strains in normal left ventricles. Conclusions: Strains measured by 2DSE agree with strain measured by magnetic resonance imaging globally but vary regionally, particularly in SVs. Global strain may be a more robust tool for cardiac functional evaluation than regional strain in SV physiology. The reliability of 2DSE-measured strain is affected by the frame rate, the nature of strain, and ventricular geometry. (J Am Soc Echocardiogr 2010; 23: 1143-52.)
引用
收藏
页码:1143 / 1152
页数:10
相关论文
共 34 条
[1]   Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging [J].
Amundsen, BH ;
Helle-Valle, T ;
Edvardsen, T ;
Torp, H ;
Crosby, J ;
Lyseggen, E ;
Stoylen, A ;
Ihlen, H ;
Lima, JAC ;
Smiseth, OA ;
Slordahl, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) :789-793
[2]   Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging [J].
Amundsen, Brage H. ;
Crosby, Jonas ;
Steen, Per Arvid ;
Torp, Hans ;
Slordahl, Stig A. ;
Stoylen, Asbjorn .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02) :229-237
[3]   Contemporary outcomes after the Fontan procedure - A pediatric heart network multicenter study [J].
Anderson, Page A. W. ;
Sleeper, Lynn A. ;
Mahony, Lynn ;
Colan, Steven D. ;
Atz, Andrew M. ;
Breitbart, Roger E. ;
Gersony, Welton M. ;
Gallagher, Dianne ;
Geva, Tal ;
Margossian, Renee ;
McCrindle, Brian W. ;
Paridon, Stephen ;
Schwartz, Marcy ;
Stylianou, Mario ;
Williams, Richard V. ;
Clark, Bernard J., III .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (02) :85-98
[4]   INFLUENCE OF THE ORIENTATION OF MYOCARDIAL FIBERS ON ECHOCARDIOGRAPHIC IMAGES [J].
AYGEN, M ;
POPP, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (01) :147-152
[5]   Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging [J].
Bansal, Manish ;
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Haluska, Brian A. ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) :1318-1325
[6]  
BHARATI S, 1996, PATHOLOGY CONGENITAL, P403
[7]  
Bogaert J, 2001, AM J PHYSIOL-HEART C, V280, pH610
[8]   INFLUENCE OF ENDOCARDIAL-EPICARDIAL CROSSOVER OF MUSCLE-FIBERS ON LEFT-VENTRICULAR WALL MECHANICS [J].
BOVENDEERD, PHM ;
HUYGHE, JM ;
ARTS, T ;
VANCAMPEN, DH ;
RENEMAN, RS .
JOURNAL OF BIOMECHANICS, 1994, 27 (07) :941-951
[9]   DEVELOPMENTAL MODULATION OF MYOCARDIAL MECHANICS - AGE-RELATED AND GROWTH-RELATED ALTERATIONS IN AFTERLOAD AND CONTRACTILITY [J].
COLAN, SD ;
PARNESS, IA ;
SPEVAK, PJ ;
SANDERS, SP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (03) :619-629
[10]   The Effect of Including Myocardial Anisotropy in Simulated Ultrasound Images of the Heart [J].
Crosby, Jonas ;
Hergum, Torbjorn ;
Remme, Espen W. ;
Torp, Hans .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) :326-333