Electrochemical immunoassay for based on polythionine and gold glassy carbon electrodes carbohydrate antigen-125 hollow microspheres modified

被引:34
作者
Fu, Xiao-Hong [1 ]
机构
[1] Yibin Univ, Sch Chem & Chem Engn, Yibin 644000, Peoples R China
关键词
electrochemical immunoassay; gold hollow microspheres; carbohydrate antigen-125; porous polythionine;
D O I
10.1002/elan.200703943
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electrochemical immunosensor for the detection of carbohydrate antigen-125 (CA125), a carcinoma antigen, was developed by immobilization CA125 antibody (anti-CA125) on gold hollow microspheres and porous polythionine (PTH) modified glassy carbon electrodes (GCE). The gold hollow microspheres provided a biocompatible microenvironment for proteins, and greatly amplified the coverage of anti-CA125 molecules on the electrode surface. The performance and factors influencing the immunosensor were investigated in detail. The detection is based on the current change before and after the antigen-antibody interaction. Under optimal conditions, the amperometric changes were proportional to CA125 concentration ranging from 4.5 to 36.5 U/mL with a detection limit of 1.3 U/mL (at 3 sigma). The CA125 immunosensor exhibited good precision, high sensitivity, acceptable stability, accuracy and reproducibility. The as-prepared immunosensors were used to analyze CA125 in human serum specimens. Analytical results suggest that the developed immunoassay has a promising alternative approach for detecting CA125 in the clinical diagnosis.
引用
收藏
页码:1831 / 1839
页数:9
相关论文
共 47 条
[1]   Multiple biomarker use for detection of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome [J].
Apple, Fred S. ;
Pearce, Lesly A. ;
Chung, Adrine ;
Ler, Ranka ;
Murakami, MaryAnn M. .
CLINICAL CHEMISTRY, 2007, 53 (05) :874-881
[2]   DYE-MODIFIED ELECTRODES FOR PHOTOGALVANIC CELLS [J].
BAULDREAY, JM ;
ARCHER, MD .
ELECTROCHIMICA ACTA, 1983, 28 (11) :1515-1522
[3]   LC-MS/MS quantification of Zn-α2 glycoprotein:: A potential serum biomarker for prostate cancer [J].
Bondar, Olga P. ;
Barnidge, David R. ;
Klee, Eric W. ;
Davis, Brian J. ;
Klee, George G. .
CLINICAL CHEMISTRY, 2007, 53 (04) :673-678
[4]   Hydroxylamine seeding of colloidal Au nanoparticles in solution and on surfaces [J].
Brown, KR ;
Natan, MJ .
LANGMUIR, 1998, 14 (04) :726-728
[5]   Nanostructured gold hollow microspheres prepared on dissolvable ceramic hollow sphere templates [J].
Chah, S ;
Fendler, JH ;
Yi, J .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2002, 250 (01) :142-148
[6]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[7]   Nanoparticle-based sensing of glycan-lectin interactions [J].
Dai, Zong ;
Kawde, Abdel-Nasser ;
Xiang, Yun ;
La Belle, Jeffrey T. ;
Gerlach, Jared ;
Bhavanandan, Veer P. ;
Joshi, Lokesh ;
Wang, Joseph .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (31) :10018-10019
[8]   Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor [J].
Hansen, JA ;
Wang, J ;
Kawde, AN ;
Xiang, Y ;
Gothelf, KV ;
Collins, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) :2228-2229
[9]  
Jana NR, 2001, LANGMUIR, V17, P6782, DOI [10.1021/la0104323, 10.1021/1a0104323]
[10]  
KANG JO, 1988, CLIN CHEM, V34, P1983