Evaluation of acute ischemic stroke using quantitative EEG: a comparison with conventional EEG and CT scan

被引:78
作者
Murri, L
Gori, S
Massetani, R
Bonanni, B
Marcella, F
Milani, S
机构
[1] Univ Pisa, Dept Neurosci, I-56126 Pisa, Italy
[2] Univ Pisa, Unit Neuroradiol, Pisa, Italy
[3] Univ Milan, Dept Biostat, I-20122 Milan, Italy
来源
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY | 1998年 / 28卷 / 03期
关键词
conventional EEG; quantitative EEG; EEG mapping; cerebral ischaemia; stroke;
D O I
10.1016/S0987-7053(98)80115-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The sensitivity of quantitative electroencephalogram (EEG) was compared with that of conventional EEG in patients with acute ischaemic stroke. In addition, a correlation between quantitative EEG data and computerized tomography (CT) scan findings was carried out for all the areas of lesion in order to reassess the actual role of EEG in the evaluation of stroke. Sixty-five patients were tested with conventional and quantitative EEG within 24 h from the onset of neurological symptoms, whereas CT scan was performed within 4 days from the onset of stroke. EEG was recorded from 19 electrodes placed upon the scalp according to the International 10-20 System. Spectral analysis was carried out on 30 artefact-free 4-sec epochs. For each channel absolute and relative power were calculated for the delta, theta, alpha and beta frequency bands and such data were successively represented in colour-coded maps. Ten patients with extensive lesions documented by CT scan were excluded. The results indicated that conventional EEG revealed abnormalities in 40 of 55 cases, while EEG mapping showed abnormalities in 46 of 55 cases: it showed focal abnormalities in five cases and nonfocal abnormalities in one of six cases which had appeared to be normal according to visual inspection of EEG. In a further 11 cases, where the conventional EEG revealed abnormalities in one hemisphere, the quantitative EEG and maps allowed to further localize abnormal activity in a more localized way. The sensitivity of both methods was higher for frontocentral, temporal and parieto-occipital cortical-subcortical infarctions than for basal ganglia and internal capsule lesions; however, quantitative EEG was more efficient for all areas of lesion in detecting cases that had appeared normal by visual inspection and was clearly superior in revealing focal abnormalities. When we considered the electrode related to which the maximum power of the delta frequency band is recorded, a fairly close correlation was found between the localization of the maximum delta power and the position of lesions documented by CT scan for all areas of lesion excepting those located in the striatocapsular area. (C) 1998 Elsevier, Paris.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
[41]   Utility of EEG measures of brain function in patients with acute stroke [J].
Wu, Jennifer ;
Srinivasan, Ramesh ;
Quinlan, Erin Burke ;
Solodkin, Ana ;
Small, Steven L. ;
Cramer, Steven C. .
JOURNAL OF NEUROPHYSIOLOGY, 2016, 115 (05) :2399-2405
[42]   Quantitative EEG parameters for monitoring and biofeedback during rehabilitation after stroke [J].
Kanna, Suresh ;
Heng, John .
2009 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1-3, 2009, :1678-+
[43]   Comparison of EEG synchrony measures for post-stroke neurorehabilitation [J].
Kawano, Teiji ;
Hattori, Noriaki ;
Uno, Yutaka ;
Hatakenaka, Megumi ;
Yagura, Hajime ;
Fujimoto, Hiroaki ;
Yoshioka, Tomomi ;
Nagasako, Michiko ;
Otomune, Hironori ;
Kitajo, Keiichi ;
Miyai, Ichiro .
2018 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2018, :35-38
[44]   Quantitative EEG patterns following unilateral stroke: A study in chronic stage [J].
Mattia, D ;
Spanedda, F ;
Babiloni, F ;
Romigi, A ;
Marciani, MG .
INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2003, 113 (04) :465-482
[45]   A Comparison of Automated and Manual Volumetric Analysis of CT Perfusion in Acute Ischemic Stroke Patients [J].
Donleavy, Bailey ;
Chung, Lee ;
Wang, Haimei ;
Majersik, Jennifer ;
de Havenon, Adam .
STROKE, 2016, 47
[46]   Analysis of generalized interictal discharges using quantitative EEG [J].
da Silva Braga, Aline Marques ;
Fujisao, Elaine Keiko ;
Betting, Luiz Eduardo .
EPILEPSY RESEARCH, 2014, 108 (10) :1740-1747
[47]   ASSESSMENT OF CEREBRAL PERFUSION USING QUANTITATIVE EEG CORDANCE [J].
LEUCHTER, AF ;
COOK, IA ;
MENA, I ;
DUNKIN, JJ ;
CUMMINGS, JL ;
NEWTON, TF ;
MIGNECO, O ;
LUFKIN, RB ;
WALTER, DO ;
LACHENBRUCH, PA .
PSYCHIATRY RESEARCH-NEUROIMAGING, 1994, 55 (03) :141-152
[48]   Quantitative permeability magnetic resonance imaging in acute ischemic stroke: how long do we need to scan? [J].
Vidarsson, Logi ;
Thornhill, Rebecca E. ;
Liu, Fang ;
Mikulis, David J. ;
Kassner, Andrea .
MAGNETIC RESONANCE IMAGING, 2009, 27 (09) :1216-1222
[49]   Classification of upper limb impairment in acute stroke patients using resting-state EEG markers and machine learning [J].
Lassi, Michael ;
Bandini, Andrea ;
Spina, Vincenzo ;
Azzollini, Valentina ;
Dalise, Stefania ;
Mazzoni, Alberto ;
Chisari, Carmelo ;
Micera, Silvestro .
2023 11TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, NER, 2023,
[50]   Predictive value of acute EEG measurements for seizures and epilepsy after stroke using a dry cap electrode EEG system - Study design and proof of concept [J].
Doerrfuss, Jakob I. ;
Kilic, Tayfun ;
Ahmadi, Michael ;
Weber, Joachim E. ;
Holtkamp, Martin .
EPILEPSY & BEHAVIOR, 2020, 104