Evaluation of acute ischemic stroke using quantitative EEG: a comparison with conventional EEG and CT scan

被引:76
作者
Murri, L
Gori, S
Massetani, R
Bonanni, B
Marcella, F
Milani, S
机构
[1] Univ Pisa, Dept Neurosci, I-56126 Pisa, Italy
[2] Univ Pisa, Unit Neuroradiol, Pisa, Italy
[3] Univ Milan, Dept Biostat, I-20122 Milan, Italy
来源
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY | 1998年 / 28卷 / 03期
关键词
conventional EEG; quantitative EEG; EEG mapping; cerebral ischaemia; stroke;
D O I
10.1016/S0987-7053(98)80115-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The sensitivity of quantitative electroencephalogram (EEG) was compared with that of conventional EEG in patients with acute ischaemic stroke. In addition, a correlation between quantitative EEG data and computerized tomography (CT) scan findings was carried out for all the areas of lesion in order to reassess the actual role of EEG in the evaluation of stroke. Sixty-five patients were tested with conventional and quantitative EEG within 24 h from the onset of neurological symptoms, whereas CT scan was performed within 4 days from the onset of stroke. EEG was recorded from 19 electrodes placed upon the scalp according to the International 10-20 System. Spectral analysis was carried out on 30 artefact-free 4-sec epochs. For each channel absolute and relative power were calculated for the delta, theta, alpha and beta frequency bands and such data were successively represented in colour-coded maps. Ten patients with extensive lesions documented by CT scan were excluded. The results indicated that conventional EEG revealed abnormalities in 40 of 55 cases, while EEG mapping showed abnormalities in 46 of 55 cases: it showed focal abnormalities in five cases and nonfocal abnormalities in one of six cases which had appeared to be normal according to visual inspection of EEG. In a further 11 cases, where the conventional EEG revealed abnormalities in one hemisphere, the quantitative EEG and maps allowed to further localize abnormal activity in a more localized way. The sensitivity of both methods was higher for frontocentral, temporal and parieto-occipital cortical-subcortical infarctions than for basal ganglia and internal capsule lesions; however, quantitative EEG was more efficient for all areas of lesion in detecting cases that had appeared normal by visual inspection and was clearly superior in revealing focal abnormalities. When we considered the electrode related to which the maximum power of the delta frequency band is recorded, a fairly close correlation was found between the localization of the maximum delta power and the position of lesions documented by CT scan for all areas of lesion excepting those located in the striatocapsular area. (C) 1998 Elsevier, Paris.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [21] Prognostic Value of EEG Microstates in Acute Stroke
    Zappasodi, Filippo
    Croce, Pierpaolo
    Giordani, Alessandro
    Assenza, Giovanni
    Giannantoni, Nadia M.
    Profice, Paolo
    Granata, Giuseppe
    Rossini, Paolo M.
    Tecchio, Franca
    BRAIN TOPOGRAPHY, 2017, 30 (05) : 698 - 710
  • [22] ELM (Extreme Learning Machine) Method for Detecting Acute Ischemic Stroke using Conventional and Specific Asymmetry BSI (Brain Symmetry Index) features based on EEG Signals
    Chan, Ji Ye
    Wijaya, Sastra K.
    Prawito
    Rahma, Osmalina N.
    3RD BIOMEDICAL ENGINEERING'S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, AND MEDICAL DEVICES, 2019, 2092
  • [23] Abnormal EEG Power Spectra in Acute Transient Global Amnesia: A Quantitative EEG Study
    Imperatori, Claudio
    Farina, Benedetto
    Todini, Federico
    Di Blasi, Chiara
    Mazzucchi, Edoardo
    Brunetti, Valerio
    Della Marca, Giacomo
    CLINICAL EEG AND NEUROSCIENCE, 2019, 50 (03) : 188 - 195
  • [24] An Analysis of EEG Signal Generated from Ischemic Stroke Patient
    Omari, W. R. W.
    Mohamad, Z.
    Taibi, M. N.
    Jailani, R.
    2015 Innovation & Commercialization of Medical Electronic Technology Conference (ICMET), 2015, : 74 - 77
  • [25] Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index
    van Putten, MJAM
    Tavy, DLJ
    STROKE, 2004, 35 (11) : 2489 - 2492
  • [26] Stroke identification using a portable EEG device - A pilot study
    Gottlibe, Matan
    Rosen, Oren
    Weller, Boaz
    Mahagney, Ayed
    Omar, Nicola
    Khuri, Ala
    Srugo, Isaac
    Genizi, Jacob
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2020, 50 (01): : 21 - 25
  • [27] Quantitative EEG Correlates of Low Cerebral Perfusion in Severe Stroke
    Diedler, Jennifer
    Sykora, Marek
    Bast, Thomas
    Poli, Sven
    Veltkamp, Roland
    Mellado, Patricio
    Steiner, Thorsten
    Rupp, Andre
    NEUROCRITICAL CARE, 2009, 11 (02) : 210 - 216
  • [28] Quantitative EEG Correlates of Low Cerebral Perfusion in Severe Stroke
    Jennifer Diedler
    Marek Sykora
    Thomas Bast
    Sven Poli
    Roland Veltkamp
    Patricio Mellado
    Thorsten Steiner
    André Rupp
    Neurocritical Care, 2009, 11 : 210 - 216
  • [29] A Novel Nonlinear Dynamic Method for Stroke Rehabilitation Effect Evaluation Using EEG
    Zeng, Hong
    Dai, Guojun
    Kong, Wanzeng
    Chen, Fangyue
    Wang, Luyun
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (12) : 2480 - 2489
  • [30] Detection of Brain Stroke using Electroencephalography (EEG)
    Garg, Pinanshu
    Sonker, Prateek Kumar
    Shakya, Kshitij
    Khurana, Dheeraj
    Roy, Shubhajit
    2019 13TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2019,