Photoionization-Generated Dibromomethane Cation Chemical Ionization Source for Time-of-Flight Mass Spectrometry and Its Application on Sensitive Detection of Volatile Sulfur Compounds

被引:45
作者
Jiang, Jichun [1 ,2 ]
Wang, Yan [1 ,2 ]
Hou, Keyong [1 ]
Hua, Lei [1 ]
Chen, Ping [1 ]
Liu, Wei [1 ,2 ]
Xie, Yuanyuan [1 ]
Li, Haiyang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, 457 Zhongshan Rd, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Univ, 19 Yuquan Rd, Beijing 100039, Peoples R China
关键词
SINGLE-PHOTON IONIZATION; SOLID-PHASE MICROEXTRACTION; VACUUM-ULTRAVIOLET LAMP; ION FLOW TUBE; ORGANIC-COMPOUNDS; SIFT-MS; PHOTOELECTRON IONIZATION; GAS-CHROMATOGRAPHY; MEMBRANE INLET; VUV-LAMP;
D O I
10.1021/acs.analchem.6b00428
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Soft ionization mass spectrometry is one of the key techniques for rapid detection of trace volatile organic compounds. In this work, a novel photoionization-generated dibromomethane cation chemical ionization (PDCI) source has been developed for time-of-flight mass spectrometry (TOFMS). Using a commercial VUV lamp, a stable flux of CH2Br2+ was generated with 1000 ppmv dibromomethane (CH2Br2) as the reagent gas, and the analytes were further ionized by reaction with CH2Br2+ cation via charge transfer and ion association. Five typical volatile sulfur compounds (VSCs) were chosen to evaluate the performance of the new ion source. The limits of detection (LOD), 0.01 ppbv for dimethyl sulfide and allyl methyl sulfide, 0.05 ppbv for carbon disulfide and methanthiol, and 0.2 ppbv for hydrogen sulfide were obtained. Compared to direct single photon ionization (SPI), the PDCI has two distinctive advantages: first, the signal intensities were greatly enhanced, for example more than 10-fold for CH3SH and CS2; second, H2S could be measured in PDCI by formation [H2S + CH2Br2](+) adduct ion and easy to recognize. Moreover, the rapid analytical capacity of this ion source was demonstrated by analysis of trace VSCs in breath gases of healthy volunteers and sewer gases.
引用
收藏
页码:5028 / 5032
页数:5
相关论文
共 42 条
  • [21] Evaluation of solid-phase microextraction for time-weighted average sampling of volatile sulfur compounds at ppb concentrations
    Lestremau, F
    Andersson, FAT
    Desauziers, V
    Fanlo, JL
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2626 - 2632
  • [22] A thermal decomposition study of polymers by tunable synchrotron vacuum ultraviolet photoionization mass spectrometry
    Li, Jiao
    Cai, Jianghuai
    Yuan, Tao
    Guo, Huijun
    Qi, Fei
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (09) : 1269 - 1274
  • [23] Analysis of sulfur-containing compounds in ambient air using solid-phase microextraction and gas chromatography with pulsed flame photometric detection
    Li, KC
    Shooter, D
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (10) : 749 - 760
  • [24] Proton-transfer-reaction mass spectrometry (PTR-MS): on-line monitoring of volatile organic compounds at pptv levels
    Lindinger, W
    Hansel, A
    Jordan, A
    [J]. CHEMICAL SOCIETY REVIEWS, 1998, 27 (05) : 347 - 354
  • [25] Trace determination of volatile sulfur compounds by solid-phase microextraction and GC-MS
    Nielsen, AT
    Jonsson, S
    [J]. ANALYST, 2002, 127 (08) : 1045 - 1049
  • [26] A study of sulfur-containing compounds in mouth- and nose-exhaled breath and in the oral cavity using selected ion flow tube mass spectrometry
    Pysanenko, A.
    Spanel, P.
    Smith, D.
    [J]. JOURNAL OF BREATH RESEARCH, 2008, 2 (04)
  • [27] Highly Resolved Online Organic-Chemical Speciation of Evolved Gases from Thermal Analysis Devices by Cryogenically Modulated Fast Gas Chromatography Coupled to Single Photon Ionization Mass Spectrometry
    Saraji-Bozorgzad, Mohammad R.
    Eschner, Markus
    Groeger, Thomas M.
    Streibel, Thorsten
    Geissler, Robert
    Kaisersbeiger, Erwin
    Denner, Thomas
    Zimmermann, Ralf
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9644 - 9653
  • [28] Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS
    Schwarz, K.
    Filipiak, W.
    Amann, A.
    [J]. JOURNAL OF BREATH RESEARCH, 2009, 3 (02)
  • [29] Breath biomarkers for detection of human liver diseases: preliminary study
    Sehnert, SS
    Jiang, L
    Burdick, JF
    Risby, TH
    [J]. BIOMARKERS, 2002, 7 (02) : 174 - 187
  • [30] Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
    Smith, D
    Spanel, P
    [J]. MASS SPECTROMETRY REVIEWS, 2005, 24 (05) : 661 - 700