Removal efficiency of subsurface vertical flow constructed wetlands for different organic loads

被引:27
作者
Langergraber, G.
Prandtstetten, C.
Pressl, A.
Rohrhofer, R.
Haberl, R.
机构
[1] Univ Nat Resources & Appl Life Sci, Inst Sanitary Engn & Water Pollut Control, Vienna BOKU, A-1190 Vienna, Austria
[2] OKOREAL GmbH, A-1170 Vienna, Austria
关键词
Austrian design standards; organic load; specific surface area requirement; subsurface vertical flow constructed wetlands;
D O I
10.2166/wst.2007.495
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Using subsurface vertical flow constructed wetlands (SSVFCWs) with intermittent loading it is possible to fulfil the stringent Austrian effluent standards regarding nitrification. For small plants (less than 500 persons) standards for ammonia nitrogen concentration have to be met at water temperatures higher than 12 degrees C, effluent concentrations and treatment efficiencies for organic matter have to be met the whole year around. According to the Austrian design standards the required surface area for SSVFCWs treating wastewater was 5 m(2) per person. Within the first part of an Austrian research project the goal was to optimise, i.e. minimise the surface area requirement of vertical flow beds. Therefore, three SSVFCWs with a surface area of 20 m(2) each have been operated in parallel. The organic loads applied were 20, 27 and 40 g COD/m(2)/d, which corresponds to a specific surface area requirement of 4; 3 and 2 m(2) per PE, respectively. The paper compares the effluent concentrations and elimination efficiencies of the three parallel operated beds. It could be shown that a specific area demand of 4 m(2) per person is suitable to be included in the revision of the Austrian design standard. Additionally it could be shown that during the warmer seasons (May-October) when the temperature of the effluent is higher than 12 degrees C the specific surface area might be further reduced; even 2 m(2) per person has been proven to be adequate.
引用
收藏
页码:75 / 84
页数:10
相关论文
共 9 条
[1]  
*AEVKA, 1996, ABWASSEREMISSIONSVER
[2]  
[Anonymous], 2000, 8 IWA
[3]  
DWA, 2006, 262 DWAA
[4]  
FEHR G, 2003, BEWACHSENE BODENFILT
[5]   Constructed wetlands for the treatment of organic pollutants [J].
Raimund Haberl ;
Stefano Grego ;
Günter Langergraber ;
Robert H. Kadlec ;
Anna-Rita Cicalini ;
Susete Martins Dias ;
Julio M. Novais ;
Sylvie Aubert ;
Andre Gerth ;
Hartmut Thomas ;
Anja Hebner .
Journal of Soils and Sediments, 2003, 3 (2) :109-124
[6]   Optimization of subsurface vertical flow constructed wetlands for wastewater treatment [J].
Langergraber, G. ;
Prandtstetten, Ch. ;
Pressl, A. ;
Rohrhofer, R. ;
Haberl, R. .
WATER SCIENCE AND TECHNOLOGY, 2007, 55 (07) :71-78
[7]  
Langergraber G, 2001, MINERVA BIOTECNOL, V13, P123
[8]  
*ONORM B, 2005, B2505 ONORM
[9]  
*ONORM B, 1997, B2505 ONORM