K-edge subtraction imaging for angiography at a compact synchrotron source

被引:0
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Braig, Eva-Maria [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Herzen, Julia [1 ,2 ]
Rummeny, Ernst [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII | 2019年 / 11110卷
关键词
K-edge subtraction imaging; angiography; iodine; radiography; biomedical imaging; brilliant X-ray source; GADOLINIUM-BASED CONTRAST; CORONARY-ANGIOGRAPHY; RADIATION;
D O I
10.1117/12.2526771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
About one third of all deaths worldwide can be traced back to some form of cardiovascular disease. The gold standard for the diagnosis and interventional treatment of blood vessels is digital subtraction angiography (DSA). An alternative to DSA is K-edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and to eliminate image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the applicability in clinical routine. Over the past decades, compact synchrotron X-ray sources based on inverse Compton scattering have been evolving, which provide X-rays with sufficient brilliance and that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this study, we demonstrate a proof-of-principle KES imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown that the proposed filter-based KES method allows for iodine-contrast agent and calcium to be clearly separated, thereby providing X-ray images only showing one of the two materials. The results show that the quasi-monochromatic spectrum of the MuCLS enables filter-based K-edge subtraction imaging and can become an important tool in pre-clinical research and possible future clinical diagnostics.
引用
收藏
页数:12
相关论文
共 26 条
  • [1] Achterhold K, 2013, SCI REP-UK, V3, DOI [10.1038/srep01313, 10.1038/srep03209]
  • [2] Bacci A, 2016, P IPAC2016 BUS KOR
  • [3] Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays
    Bech, Martin
    Bunk, Oliver
    David, Christian
    Ruth, Ronald
    Rifkin, Jeff
    Loewen, Rod
    Feidenhans'l, Robert
    Pfeiffer, Franz
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 43 - 47
  • [4] Mechanisms of Plaque Formation and Rupture
    Bentzon, Jacob Fog
    Otsuka, Fumiyuki
    Virmani, Renu
    Falk, Erling
    [J]. CIRCULATION RESEARCH, 2014, 114 (12) : 1852 - 1866
  • [5] Eggl E., 2016, J SYNCHROTRON RADIAT, V23, P91
  • [6] Mono-Energy Coronary Angiography with a Compact Synchrotron Source
    Eggl, Elena
    Mechlem, Korbinian
    Braig, Eva
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Achterhold, Klaus
    Herzen, Julia
    Gleich, Bernhard
    Rummeny, Ernst
    Noel, Peter B.
    Pfeiffer, Franz
    Muenzel, Daniela
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [7] First human transvenous coronary angiography at the European Synchrotron Radiation Facility
    Elleaume, H
    Fiedler, S
    Estève, F
    Bertrand, B
    Charvet, AM
    Berkvens, P
    Berruyer, G
    Brochard, T
    Le Duc, G
    Nemoz, C
    Renier, M
    Suortti, P
    Thomlinson, W
    Le Bas, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) : L39 - L43
  • [8] Hochmuth A, 2002, AM J NEURORADIOL, V23, P1199
  • [9] DICHROMATIC ABSORPTION RADIOGRAPHY - DICHROMOGRAPHY
    JACOBSON, B
    [J]. ACTA RADIOLOGICA, 1953, 39 (06) : 437 - 452
  • [10] High intensity compact Compton X-ray sources: Challenges and potential of applications
    Jacquet, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 331 : 1 - 5