Voltammetric Determination of Paracetamol in Pharmaceutical Formulations at Iodine-Coated Polycrystalline Platinum Electrode

被引:3
作者
Amayreh, Mohammad [1 ]
Hourani, Wafa [2 ]
Hourani, Mohammed Khair [3 ]
机构
[1] Al Balqa Appl Univ, Dept Chem, Fac Sci, POB 19117, Al Salt, Jordan
[2] Philadelphia Univ, Fac Pharm, Amman, Jordan
[3] Univ Jordan, Dept Chem, Amman, Jordan
来源
METHODS AND OBJECTS OF CHEMICAL ANALYSIS | 2021年 / 16卷 / 02期
关键词
paracetamol; pharmaceutical formulation; voltammetric analysis; iodine-coated platinum electrode; modified platinum electrode; AMPEROMETRIC DETERMINATION; REDUCTIVE ELIMINATION; ACETAMINOPHEN; ADSORPTION; OXIDATION; GOLD;
D O I
10.17721/moca.2021.103-111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 43 条
[31]   Controlled release of drugs from cellulose acetate matrices produced from sugarcane bagasse: monitoring by square-wave voltammetry [J].
Rodrigues Filho, Guimes ;
Almeida, Flavia ;
Ribeiro, Sabrina D. ;
Tormin, Thiago F. ;
Munoz, Rodrigo A. A. ;
Assuncao, Rosana M. N. ;
Barud, Hernane .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2016, 42 (07) :1066-1072
[32]   SURFACE COORDINATION CHEMISTRY OF NOBLE-METAL ELECTROCATALYSTS - OXIDATIVE ADDITION AND REDUCTIVE ELIMINATION OF IODIDE AT IRIDIUM, PLATINUM AND GOLD IN AQUEOUS-SOLUTIONS [J].
RODRIGUEZ, JF ;
HARRIS, JE ;
BOTHWELL, ME ;
MEBRAHTU, T ;
SORIAGA, MP .
INORGANICA CHIMICA ACTA, 1988, 148 (01) :123-131
[33]   Simultaneous high-performance liquid chromatographic determination of paracetamol, phenylephrine HCl, and chlorpheniramine maleate in pharmaceutical dosage forms [J].
Senyuva, H ;
Özden, T .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (02) :97-100
[34]  
Shrestha B R., 2009, Journal of Nepal Chemical Society, V24, P39, DOI DOI 10.3126/JNCS.V24I0.2389
[35]   IODINE ADSORPTION STUDIES AT PLATINUM [J].
SHU, ZX ;
BRUCKENSTEIN, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 317 (1-2) :263-277
[36]   Electrochemical Oxidation and Sensitive Determination of Acetaminophen in Pharmaceuticals at Poly(3,4-ethylenedioxythiophene)-Modified Screen-Printed Electrodes [J].
Su, Wan-Yu ;
Cheng, Shu-Hua .
ELECTROANALYSIS, 2010, 22 (06) :707-714
[37]   Simultaneous determination of paracetamol and penicillin V by square-wave voltammetry at a bare boron-doped diamond electrode [J].
Svorc, Lubomir ;
Sochr, Jozef ;
Tomcik, Peter ;
Rievaj, Miroslav ;
Bustin, Dugan .
ELECTROCHIMICA ACTA, 2012, 68 :227-234
[38]   Electrochemical determination of paracetamol in presence of folic acid at nevirapine modified carbon paste electrode: A cyclic voltammetric study [J].
Tanuja, S. B. ;
Swamy, B. E. Kumara ;
Pai, K. Vasantakumar .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 798 :17-23
[39]   Surface diffusion limited desorption of iodine on a platinum electrode? [J].
Thomas, AE ;
Wieckowski, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 399 (1-2) :207-212
[40]  
Umasankar Y, 2012, INT J ELECTROCHEM SC, V7, P484