Voltammetric Determination of Paracetamol in Pharmaceutical Formulations at Iodine-Coated Polycrystalline Platinum Electrode

被引:3
作者
Amayreh, Mohammad [1 ]
Hourani, Wafa [2 ]
Hourani, Mohammed Khair [3 ]
机构
[1] Al Balqa Appl Univ, Dept Chem, Fac Sci, POB 19117, Al Salt, Jordan
[2] Philadelphia Univ, Fac Pharm, Amman, Jordan
[3] Univ Jordan, Dept Chem, Amman, Jordan
来源
METHODS AND OBJECTS OF CHEMICAL ANALYSIS | 2021年 / 16卷 / 02期
关键词
paracetamol; pharmaceutical formulation; voltammetric analysis; iodine-coated platinum electrode; modified platinum electrode; AMPEROMETRIC DETERMINATION; REDUCTIVE ELIMINATION; ACETAMINOPHEN; ADSORPTION; OXIDATION; GOLD;
D O I
10.17721/moca.2021.103-111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 43 条
[11]   Simple Flow Injection Amperometric System for Simultaneous Determination of Dipyrone and Paracetamol in Pharmaceutical Formulations [J].
dos Santos, Wallans T. P. ;
Gimenes, Denise T. ;
de Almeida, Edimar G. N. ;
Eiras, Sebastiao de P. ;
Albuquerque, Yaico D. T. ;
Richter, Eduardo M. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (07) :1249-1255
[12]  
[EC] European Commission, 2017, OFF J EUR UNION, V01, P1
[13]   Carbon film resistor electrode for amperometric determination of acetaminophen in pharmaceutical formulations [J].
Felix, Fabiana S. ;
Brett, Christopher M. A. ;
Angnes, Lucio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1622-1627
[14]  
FELTER TE, 1979, J ELECTROANAL CHEM, V100, P473, DOI 10.1016/S0022-0728(79)80179-5
[15]  
Gupta SRN., 2016, MED CHEM, V6, P47
[16]   REDUCTIVE ELIMINATION OF SURFACE-COORDINATED IODINE AT PLATINUM-ELECTRODES - THE INFLUENCE OF CODEPOSITED SILVER [J].
HARRIS, JE ;
BOTHWELL, ME ;
RODRIGUEZ, JF ;
SORIAGA, MP ;
STICKNEY, JL .
JOURNAL OF PHYSICAL CHEMISTRY, 1989, 93 (06) :2610-2614
[17]   DETERMINATION OF SILVER(I) BY CYCLIC VOLTAMMETRY AT IODINE-COATED ELECTRODES [J].
HOURANI, MK .
ANALYST, 1994, 119 (09) :1975-1978
[18]   Simultaneous voltammetric determination of paracetamol, cetirizine and phenylephrine using a multiwalled carbon nanotube-platinum nanoparticles nanocomposite modified carbon paste electrode [J].
Kalambate, Pramod K. ;
Srivastava, Ashwini K. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 :237-248
[19]   High-sensitivity paracetamol sensor based on Pd/graphene oxide nanocomposite as an enhanced electrochemical sensing platform [J].
Li, Junhua ;
Liu, Jinlong ;
Tan, Gongrong ;
Jiang, Jianbo ;
Peng, Sanjun ;
Deng, Miao ;
Qian, Dong ;
Feng, Yonglan ;
Liu, Youcai .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :468-475
[20]   HYDROGENATIVE CATHODIC STRIPPING OF IODINE CHEMISORBED ON SMOOTH POLYCRYSTALLINE PLATINUM-ELECTRODES [J].
MEBRAHTU, T ;
RODRIGUEZ, JF ;
BRAVO, BG ;
SORIGA, MP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 219 (1-2) :327-333