Construction of a bilirubin biosensor based on an albumin-immobilized quartz crystal microbalance

被引:3
作者
Kocakulak, Mustafa [1 ]
Bayrak, Tuncay [1 ]
Saglam, Sinan [1 ]
机构
[1] Baskent Univ, Biomed Engn Dept, Eskisehir Rd 20 Km,Baglica Campus, Ankara, Turkey
关键词
Bilirubin detection; Quartz crystal microbalance; Biosensor; Biosensor based on albumin; QCM; Albumin; HUMAN-SERUM-ALBUMIN; HUMAN PLASMA; CARBON NANOTUBES; THIN-FILM; ADSORPTION; REMOVAL; AFFINITY; SENSOR; OXIDASE; SYSTEM;
D O I
10.1016/j.bbe.2017.05.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bilirubin, a bile pigment, is associated with several diseases and systemic pathologies. The measurement of bilirubin is important for diagnosis and therapy, and many expensive methods are used to measure the bilirubin amount in blood. In this study, a new bilirubin biosensor using quartz crystal microbalances immobilized with albumin is proposed. To measure the effectiveness of the biosensor, a series of experiments was realized with various concentrations of bilirubin, including 1 mg/dL, 2 mg/dL, 5 mg/dL and 10 mg/dL. Comparing blood gas analyzers, laboratory analyzers, skin test devices and nonchemical photometric devices, blood gas analyzers have a range of 0.5-35 mg/dL, laboratory analyzers have a range of 0-30 mg/dL, skin test devices could be used up to 11.7 mg/dL, and nonchemical photometric devices could be evaluated as reliable up to 14.6 mg/dL. The low limit range of the bilirubin detection is between 0.099 mg/dL and 0.146 mg/dL for some special commercial bilirubin measurement devices. Nevertheless, this study presents measurements with a high sensitivity and includes the advantage of reusability by using cheaper materials. To prove albumin immobilization and the bilirubin-albumin interaction atomic force microscopy (AFM) was used, and a good correlation was achieved from AFM images. In conclusion, considering the cost-effectiveness side of the proposed method, a low cost and more sensitive bilirubin measurement device which is effective and reusable was developed instead of the current commercial products. (C) 2017 Nalecz Institute of Biocybernetics and Biomedical Engineering of the Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:611 / 617
页数:7
相关论文
共 36 条
[11]  
2-G
[12]  
Ermek E, 2010, THESIS
[13]   Synthesis of the multi-walled carbon nanotubes-COOH/graphene/gold nanoparticles nanocomposite for simple determination of Bilirubin in human blood serum [J].
Feng, Qingliang ;
Du, Yongling ;
Zhang, Chao ;
Zheng, Zhixiang ;
Hu, Fangdi ;
Wang, Zaihua ;
Wang, Chunming .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 :337-344
[14]   Bilirubin measurement for neonates:: Comparison of 9 frequently used methods [J].
Grohmann, K ;
Roser, M ;
Rolinski, B ;
Kadow, I ;
Müller, C ;
Goerlach-Graw, A ;
Nauck, M ;
Küster, H .
PEDIATRICS, 2006, 117 (04) :1174-1183
[15]   QCM biosensor for testing the inflammatory response to blood-contacting biomaterials [J].
Haberal, Erdem ;
Ugur, Nurcin ;
Kocakulak, Mustafa .
ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2013, 41 (03) :222-226
[16]   Bilirubin oxidation in brain [J].
Hansen, TWR .
MOLECULAR GENETICS AND METABOLISM, 2000, 71 (1-2) :411-417
[17]  
JACOBSEN J, 1977, INT J PEPT PROT RES, V9, P235
[18]   DESIGN OF TEMPERATURE CONTROLLED QUARTZ CRYSTAL MICROBALANCE SYSTEM [J].
Kocum, C. ;
Erdamar, A. ;
Ayhan, H. .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (01) :39-51
[19]   IMPROVE THE DATA ACQUISITION SYSTEM OF A QCM SENSOR BY INCREASING THE SAMPLING RATE OF FREQUENCY AND AMPLITUDE [J].
Lee, Chao-Fa ;
Yan, Tsong-Rong ;
Chou, Hung-Che .
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2009, 21 (06) :405-410
[20]   Cardiac troponin T mutation R141W found in dilated cardiomyopathy stabilizes the troponin T-tropomyosin interaction and causes a Ca2+ desensitization [J].
Lu, QW ;
Morimoto, S ;
Harada, K ;
Du, CK ;
Takahashi-Yanaga, F ;
Miwa, Y ;
Sasaguri, T ;
Ohtsuki, I .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2003, 35 (12) :1421-1427