Design of Improved Flow-Focusing Microchannel with Constricted Continuous Phase Inlet and Study of Fluid Flow Characteristics

被引:7
作者
Wang, Zhaohui [1 ]
Ding, Weibing [1 ]
Fan, Yiwei [1 ]
Wang, Jian [1 ]
Chen, Jie [2 ]
Wang, Hongxia [3 ]
机构
[1] Wuhan Univ Sci & Technol, Minist Educ, Key Lab Met Equipment & Control Technol, Wuhan 430081, Peoples R China
[2] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[3] Hubei Univ Automot Technol, Coll Mech Engn, Shiyan 442002, Peoples R China
基金
中国国家自然科学基金;
关键词
flow-focusing microchannel; RBF model; microbubbles; optimal design; flow characteristics; BUBBLE FORMATION; MICROFLUIDIC FABRICATION; SENSITIVITY-ANALYSIS; MICROBUBBLES; MICROCAPSULES; VALUES; MODEL;
D O I
10.3390/mi13101776
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposed an improved flow-focusing microchannel with a constricted continuous phase inlet to increase microbubble generation frequency and reduce microbubbles' diameter. The design variables were obtained by Latin hypercube sampling, and the radial basis function (RBF) surrogate model was used to establish the relationship between the objective function (microbubble diameter and generation frequency) and the design variables. Moreover, the optimized design of the nondominated sorting genetic algorithm II (NSGA-II) algorithm was carried out. Finally, the optimization results were verified by numerical simulations and compared with those of traditional microchannels. The results showed that dripping and squeezing regimes existed in the two microchannels. The constricted continuous phase inlet enhanced the flow-focusing effect of the improved microchannel. The diameter of microbubbles obtained from the improved microchannel was reduced from 2.8141 to 1.6949 mu m, and the generation frequency was increased from 64.077 to 175.438 kHz at the same capillary numbers (Ca) compared with the traditional microchannel. According to the fitted linear function, it is known that the slope of decreasing microbubble diameter with increasing Ca number and the slope of increasing generation frequency with increasing Ca number are greater in the improved microchannel compared with those in the traditional microchannel.
引用
收藏
页数:21
相关论文
共 39 条
  • [1] Microfluidic Fabrication of Stable Gas-Filled Microcapsules for Acoustic Contrast Enhancement
    Abbaspourrad, Alireza
    Duncanson, Wynter J.
    Lebedeva, Natalia
    Kim, Shin-Hyun
    Zhushma, Aleksandr P.
    Datta, Sujit S.
    Dayton, Paul A.
    Sheiko, Sergei S.
    Rubinstein, Michael
    Weitz, David A.
    [J]. LANGMUIR, 2013, 29 (40) : 12352 - 12357
  • [2] A novel sensitivity analysis model of EANN for F-MWCNTs-Fe3O4/EG nanofluid thermal conductivity: Outputs predicted analytically instead of numerically to more accuracy and less costs
    Bagherzadeh, Seyed Amin
    D'Orazio, Annunziata
    Karimipour, Arash
    Goodarzi, Marjan
    Quang-Vu Bach
    [J]. PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2019, 521 : 406 - 415
  • [3] Investigation of pressure profile evolution during confined microdroplet formation using a two-phase level set method
    Bashir, Shazia
    Rees, Julia M.
    Zimmerman, Willam B.
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2014, 60 : 40 - 49
  • [4] Preparation of monodisperse polymer particles and capsules by ink-jet printing
    Bohmer, Marcel R.
    Schroeders, Richard
    Steenbakkers, Jan A. M.
    de Winter, Suzanne H. P. M.
    Duineveld, Paul A.
    Lub, Johan
    Nijssen, Wim P. M.
    Pikkemaat, Jeroen A.
    Stapert, Henk R.
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 289 (1-3) : 96 - 104
  • [5] Microbubble generation in a co-flow device operated in a new regime
    Castro-Hernandez, Elena
    van Hoeve, Wim
    Lohse, Detlef
    Gordillo, Jose M.
    [J]. LAB ON A CHIP, 2011, 11 (12) : 2023 - 2029
  • [6] DNS using CLSVOF method of single micro-bubble breakup and dynamics in flow focusing
    Chekifi, Tawfiq
    Boukraa, Moustafa
    Aissani, Mouloud
    [J]. JOURNAL OF VISUALIZATION, 2021, 24 (03) : 519 - 530
  • [7] Ultrasound contrast agents: An overview
    Cosgrove, David
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 324 - 330
  • [8] A fast and elitist multiobjective genetic algorithm: NSGA-II
    Deb, K
    Pratap, A
    Agarwal, S
    Meyarivan, T
    [J]. IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) : 182 - 197
  • [9] Bubble Formation Dynamics in Various Flow-Focusing Microdevices
    Dietrich, N.
    Poncin, S.
    Midoux, N.
    Li, Huai Z.
    [J]. LANGMUIR, 2008, 24 (24) : 13904 - 13911
  • [10] ENHANCED INTRACELLULAR DELIVERY OF A MODEL DRUG USING MICROBUBBLES PRODUCED BY A MICROFLUIDIC DEVICE
    Dixon, Adam J.
    Dhanaliwala, Ali H.
    Chen, Johnny L.
    Hossack, John A.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (07) : 1267 - 1276