Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography

被引:84
|
作者
Boulin, A [1 ]
Pierot, L [1 ]
机构
[1] Hop Foch, Dept Diagnost & Therapeut Neuroradiol, F-92151 Suresnes, France
关键词
aneurysm; intracranial; rupture; therapy; angiography; comparative studies; interventional procedures;
D O I
10.1148/radiology.219.1.r01mr06108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare three-dimensional (3D) time-of-flight magnetic resonance (MR) angiography with digital subtraction angiography (DSA) in the follow-up of intracranial aneurysms treated with selective endovascular placement of detachable coils. MATERIALS AND METHODS: Sixty-eight consecutive patients with intracranial aneurysms were included in the prospective study. The goal was to evaluate 3D time-of-flight MR angiography versus DSA for the detection of a residual aneurysm neck or residual flow inside the coil mesh. RESULTS: Eighty-one MR angiographic and 83 DSA examinations were performed; 15 patients were examined with both modalities twice. MR angiography was not possible in two patients. In another patient, the quality of MR angiography was not sufficient to assess the treated aneurysm. In 72 of the remaining 80 MR angiographic and DSA examinations, there was good correlation between the two modalities. In 54 cases, neither image type showed remnants or recurrence, but in 18, both showed residual aneurysm. In eight cases, the MR angiographic and DSA results differed. In one of these cases, MR angiography depicted residual aneurysm but DSA depicted an arterial loop. In seven cases, a small (<3-mm) remnant was not detected at MR angiography. CONCLUSION: Because very small aneurysm remnants or recurrences probably are not clinically important, MR angiography is an option for following up intracranial aneurysms treated with detachable coils and may partly replace DSA.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [1] Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography
    Cottier, JP
    Bleuzen-Couthon, A
    Gallas, S
    Vinikoff-Sonier, CB
    Bertrand, P
    Domengie, F
    Barantin, L
    Herbreteau, D
    NEURORADIOLOGY, 2003, 45 (11) : 818 - 824
  • [2] Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography
    J. P. Cottier
    A. Bleuzen-Couthon
    S. Gallas
    C. B. Vinikoff-Sonier
    P. Bertrand
    F. Domengie
    L. Barantin
    D. Herbreteau
    Neuroradiology, 2003, 45 : 818 - 824
  • [3] MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils
    Majoie, CBLM
    Sprengers, ME
    van Rooij, WJJ
    Lavini, C
    Sluzewski, M
    van Rijn, JC
    den Heeten, GJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (06) : 1349 - 1356
  • [4] Intracranial aneurysms treated with Guglielmi detachable coils: Is contrast material necessary in the follow-up with 3D time-of-flight MR angiography?
    Cottier, JP
    Bleuzen-Couthon, A
    Gallas, S
    Vinikoff-Sonier, CB
    Bertrand, P
    Domengie, F
    Barantin, L
    Herbreteau, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (09) : 1797 - 1803
  • [5] Time-of-flight MR angiography at 3T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils
    Ferre, Jean-Christophe
    Carsin-Nicol, Beatrice
    Morandi, Xavier
    Carsin, Michel
    de Kersaint-Gilly, Axel
    Gauvrit, Jean-Yves
    Desal, Hubert-Armand
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 365 - 369
  • [6] Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils
    Brunereau, L
    Cottier, JP
    Sonier, CB
    Medioni, B
    Bertrand, P
    Rouleau, P
    Sirinelli, D
    Herbreteau, D
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 216 - 223
  • [7] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    Westerlaan, HE
    van der Vliet, AM
    Hew, JM
    Meiners, LC
    Metzemaekers, JDM
    Mooij, JJA
    Oudkerk, M
    NEURORADIOLOGY, 2005, 47 (08) : 622 - 629
  • [8] Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils
    H. E. Westerlaan
    A. M. van der Vliet
    J. M. Hew
    L. C. Meiners
    J. D. M. Metzemaekers
    J. J. A. Mooij
    M. Oudkerk
    Neuroradiology, 2005, 47 : 622 - 629
  • [9] Unenhanced Time-of-Flight MR Angiography versus Gadolinium-Enhanced Time-of-Flight MR Angiography in the Follow-Up of Coil-Embolized Aneurysms
    Behme, D.
    Malinova, V.
    Kallenberg, K.
    Knauth, M.
    Mohr, A.
    Journal of Neurological Surgery Part A-Central European Neurosurgery, 2016, 77 (05) : 400 - 405
  • [10] Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography
    Okahara, M
    Kiyosue, H
    Hori, Y
    Yamashita, M
    Nagatomi, H
    Mori, H
    EUROPEAN RADIOLOGY, 2004, 14 (07) : 1162 - 1168