Utility of virtual monoenergetic images derived from a dual-layer detector-based spectral CT in the assessment of aortic anatomy and pathology: A retrospective case control study

被引:19
作者
Chalian, Hamid [1 ,2 ]
Kalisz, Kevin [1 ,2 ]
Rassouli, Negin [1 ]
Dhanantwari, Amar [3 ]
Rajiah, Prabhakar [1 ,4 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, Cleveland, OH 44106 USA
[2] Duke Univ, Med Ctr, Durham, NC USA
[3] Philips Healthcare, Cleveland, OH USA
[4] UT Southwestern Med Ctr, Dept Radiol, Cardiothorac Imaging, Dallas, TX USA
关键词
Dual layered; Monoenergetic; Aorta; Enhancement; CTA; ENERGY CT; PULMONARY ANGIOGRAM; ABDOMINAL-AORTA; STANDARD; PATIENT; VOLUME;
D O I
10.1016/j.clinimag.2018.08.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the ability of the retrospectively generated virtual monoenergetic images (VMIs) from a dual-layer detector-based spectral computed tomography (SDCT) to augment aortic enhancement for the evaluation of aortic anatomy and pathology. Methods: 98 patients with suboptimal aortic enhancement (<= 200 HU) were retrospectively identified from SDCT scans. VMI from 40 to 80 keV were generated. Attenuation, noise, SNR, and CNR were measured at seven levels in the aorta. Image quality was graded on a 5-point scale, 5 being the best. From the VMI, an ideal set was chosen with mean vascular attenuation above 200 HU while maintaining diagnostic quality. Image parameters and quality of this ideal-set were compared to the standard 120-kVp images. Results: The mean attenuation of all seven measured anatomical regions was 156.6 +/- 61.7 HU in the 120-kVp images. Attenuation of the VMI from 40 to 70 keV were higher than the 120-kVp image, measuring 439.2 +/- 215.3 HU, 298.5 +/- 140.6 HU, 213.4 +/- 94.3 HU, and 164.7 +/- 90.2 HU, for 40 keV, 50 keV, 60 keV, and 70 keV, respectively (p value < 0.01 for 40, 50, 60 keV; 0.07 for 70 keV). SNR and CNR showed similar trends. The 50 keV VMI had the best image quality (4.48 +/- 0.84 vs. 2.24 +/- 0.92 on 120-kVp images, p < 0.001). Attenuation, CNR, and SNR increased by 90.6%, 85.0%, and 108.1% at 50 keV compared to 120-kVp. Conclusions: A contrast-enhanced CT study can be optimized for the assessment of the aorta by using low-energy VMI obtained using SDCT. At the optimal monoenergetic level, attenuation, SNR, CNR and image quality were significantly higher than that of conventional polyenergetic images.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 30 条
[1]   Optimization of window settings for standard and advanced virtual monoenergetic imaging in abdominal dual-energy CT angiography [J].
Caruso, Damiano ;
Parinella, Ashley H. ;
Schoepf, U. Joseph ;
Stroebel, Maxwell H. ;
Mangold, Stefanie ;
Wichmann, Julian L. ;
Varga-Szemes, Akos ;
Ball, B. Devon, Jr. ;
De Santis, Domenico ;
Laghi, Andrea ;
De Cecco, Carlo N. .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :772-780
[2]   Contrast opacification on thoracic CT angiography: challenges and solutions [J].
Chaturvedi, Abhishek ;
Oppenheimer, Daniel ;
Rajiah, Prabhakar ;
Kaproth-Joslin, Katherine A. ;
Chaturvedi, Apeksha .
INSIGHTS INTO IMAGING, 2017, 8 (01) :127-140
[3]   Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism [J].
Cheng, Jiejun ;
Yin, Yan ;
Wu, Huawei ;
Zhang, Qing ;
Hua, Jia ;
Hua, Xiaolan ;
Xu, Jianrong .
PLOS ONE, 2013, 8 (05)
[4]   Poly-energetic and virtual mono-energetic images from a novel dual-layer spectral detector CT: optimization of window settings is crucial to improve subjective image quality in abdominal CT angiographies [J].
Doerner, Jonas ;
Luetkens, Julian A. ;
Iuga, Andra-Iza ;
Byrtus, Jonathan ;
Haneder, Stefan ;
Maintz, David ;
Hickethier, Tilman .
ABDOMINAL RADIOLOGY, 2018, 43 (03) :742-750
[5]   Low-Contrast Agent Dose Dual-Energy CT Monochromatic Imaging in Pulmonary Angiography Versus Routine CT [J].
Dong, Jian ;
Wang, Xiaoying ;
Jiang, Xuexiang ;
Gao, Li ;
Li, Feiyu ;
Qiu, Jianxing ;
Xu, Yufeng ;
Wang, He .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) :618-625
[6]   Methods for Clinical Evaluation of Noise Reduction Techniques in Abdominopelvic CT [J].
Ehman, Eric C. ;
Yu, Lifeng ;
Manduca, Armando ;
Hara, Amy K. ;
Shiung, Maria M. ;
Jondal, Dayna ;
Lake, David S. ;
Paden, Robert G. ;
Blezek, Daniel J. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. ;
Hough, David M. ;
Fletcher, Joel G. .
RADIOGRAPHICS, 2014, 34 (04) :849-862
[7]   Computed Tomography Angiography A Review and Technical Update [J].
Fleischmann, Dominik ;
Chin, Anne S. ;
Molvin, Lior ;
Wang, Jia ;
Hallett, Richard .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2016, 54 (01) :1-+
[8]   Abdominal Applications of a Novel Detector-Based Spectral CT [J].
Fulton, Nicholas ;
Rajiah, Prabhakar .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2018, 47 (02) :110-118
[9]   Single-Acquisition Dual-Energy Multidetector Computed Tomography: Analysis of Vascular Enhancement and Postprocessing Techniques for Evaluating the Thoracic Aorta [J].
Godoy, Myrna C. B. ;
Naidich, David P. ;
Marchiori, Edson ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Assadourian, Bernard ;
Vlahos, Ioannis .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) :670-677
[10]   Contrast dynamics during CT pulmonary angiogram - Analysis of an inspiration associated artifact [J].
Gosselin, MV ;
Rassner, UA ;
Thieszen, SL ;
Phillips, J ;
Oki, A .
JOURNAL OF THORACIC IMAGING, 2004, 19 (01) :1-7