A novel hydrogen peroxide biosensor based on hemoglobin immobilized on magnetic chitosan microspheres modified electrode

被引:79
|
作者
Lai, Guo-Song [1 ,2 ]
Zhang, Hai-Li [1 ]
Han, De-Yan [1 ]
机构
[1] Hubei Normal Univ, Dept Chem & Environm Engn, Hubei Key Lab Bioanalyt Tech, Huangshi 435002, Peoples R China
[2] Cent China Normal Univ, Coll Chem, Wuhan 430079, Peoples R China
关键词
hemoglobin; hydrogen peroxide; magnetic microspheres; biosensor; methylene blue;
D O I
10.1016/j.snb.2007.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel magnetic chitosan microsphere (MCMS) was prepared using carbon-coated iron magnetic nanoparticles and chitosan. Hemoglobin (Hb) was successfully immobilized on the surface of MCMS modified glassy carbon electrode (GCE) with the cross-linking of glutaraldehyde, and the immobilized Hb displayed an excellent electrocatalytic property to the reduction of H2O2 in the presence of the mediator of methylene blue (MB). The effects of the experimental variables such as the concentration of MB, solution pH and the working potential were investigated for optimum analytical performance using steady-state amperometry. This biosensor had a fast response of H2O2 less than 10 s and excellent linear relationships were obtained in the concentration range of 0.069-0.29 mM and 0.29-3.0 mM with the detection limit of 0.021 mM (S/N = 3) under the optimum conditions. Moreover, the selectivity, stability and reproducibility of this biosensor were evaluated with satisfactory results. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 50 条
  • [1] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Hai-Li Zhang
    Guo-Song Lai
    De-Yan Han
    Ai-Min Yu
    Analytical and Bioanalytical Chemistry, 2008, 390 : 971 - 977
  • [2] Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres
    Tan, Xue-Cai
    Zhang, Jin-Lei
    Tan, Sheng-Wei
    Zhao, Dan-Dan
    Huang, Zen-Wei
    Mi, Yan
    Huang, Zai-Yin
    SENSORS, 2009, 9 (08) : 6185 - 6199
  • [3] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Zhang, Hai-Li
    Lai, Guo-Song
    Han, De-Yan
    Yu, Ai-Min
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 971 - 977
  • [4] A Highly Sensitive Hydrogen Peroxide Biosensor Based on Hemoglobin Immobilized on Cadmium Sulfide Quantum Dots/Chitosan Composite Modified Glassy Carbon Electrode
    Butwong, Nutthaya
    Zhou, Lin
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    ELECTROANALYSIS, 2014, 26 (11) : 2465 - 2473
  • [5] Hydrogen Peroxide Biosensor based on Carbon Paste Modified Electrode with Hemoglobin and Copper(II) Oxide Nanoparticles
    Abbasi, Amin
    Shamsazar, Ali
    Shamsazar, Fatemeh
    Asadi, Asadollah
    Shamsaldini, Soghra
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (04): : 3986 - 3996
  • [6] Immobilization of Hemoglobin on the Gold Colloid Modified Pretreated Glassy Carbon Electrode for Preparing a Novel Hydrogen Peroxide Biosensor
    Liu, Yang
    Jiang, Qi-Yu
    Lu, Shuang-Yun
    Zhang, Ye
    Gu, Hai-Ying
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2009, 152 (03) : 418 - 427
  • [7] Immobilization of Hemoglobin on the Gold Colloid Modified Pretreated Glassy Carbon Electrode for Preparing a Novel Hydrogen Peroxide Biosensor
    Yang Liu
    Qi-Yu Jiang
    Shuang-Yun Lu
    Ye Zhang
    Hai-Ying Gu
    Applied Biochemistry and Biotechnology, 2009, 152 : 418 - 427
  • [8] A Novel Hydrogen Peroxide Biosensor Based on Hemoglobin/Holmium Phosphate Nanocomposites
    Huang Hai-Ping
    Xu Liang
    Yue Ya-Feng
    Lyu Lian-Lian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 111 - 117
  • [9] A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode
    Zhang, JD
    Oyama, M
    ELECTROCHIMICA ACTA, 2004, 50 (01) : 85 - 90
  • [10] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574