Effects of Zr ion implantation on crystal structure and nanoindentation behavior of TC18 titanium alloy

被引:13
作者
Li, Fengkun [1 ]
Wei, Dongbo [1 ,2 ]
Zhang, Pingze [1 ,3 ]
Chen, Xiaohu [1 ]
Ding, Feng [1 ]
Wang, Shiyuan [1 ]
Zhao, Ruibo [1 ]
Wang, Zhangzhong [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Technol, Nanjing 211106, Jiangsu, Peoples R China
[2] Nanjing Universi575ty Aeronaut & Astronaut, Minist Ind & Informat Technol, Key Lab Mat Preparat & Protect Harsh Environm, Nanjing 211106, Jiangsu, Peoples R China
[3] Jiangsu Key Lab Adv Struct Mat & Applicat Technol, Nanjing 211167, Jiangsu, Peoples R China
基金
美国国家科学基金会; 中国博士后科学基金;
关键词
TC18 titanium alloy; Zr ion implantation; crystal structure; XRD; nanoindentation behavior; FATIGUE; TRIBOLOGY; RESISTANCE; OXIDATION; CORROSION; METALS; CARBON;
D O I
10.1088/2053-1591/aaf1ee
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, TC18 titanium alloy was ion implanted with Zr ions to a fluence of 3.56 x 10(16), 5.53 x 10(16) and 7.12 x 10(16) ions cm(-2). The surface morphologies were characterized by the scanning electron microscopy (SEM) and atomic force microscope (AFM). The crystal structure of the Zr implanted TC18 titanium alloy was evaluated by the x-ray diffraction (XRD) and the corresponding calculations were used to analysis the nanoindentation behavior. Nanoindentation tests with different loads (5 mN, 10 mN and 15 mN) were used to investigate the nanoindentation behavior of samples. Zr ion implantation not only affected the surface microstructures of substrate, but also affected the crystal structure. When the implantation fluence was 3.56 x 10(16) ions cm(-2), the surface roughness of sample was reduced, while the residual compressive stress caused the XRD peak shift to higher angle compared with the baseline of substrate. The irradiation effect increases with increasing implantation fluence which led to generation of etch pits and cracks, and therefore increased surface roughness of TC18 titanium alloy. At the same time, the increase of lattice parameters shifted the XRD peak to low angle. The result of nanoindentation test showed that Zr solid solution strengthening improved the hardness of substrate. However, the dislocation density gradually decreased with the increasing of implantation fluence, which therefore reduced the nanohardness of samples. The highest hardness values of TC18 titanium alloy under different indentation loads were all found in samples treated with the ion fluence of 3.56 x 10(16) ions cm(-2), as a result of Zr solid solution strengthening and high dislocation density.
引用
收藏
页数:10
相关论文
共 28 条
[1]   Influence of molybdenum ion implantation on the localized corrosion resistance of a high strength aluminium alloy [J].
Abreu, C. M. ;
Cristobal, M. J. ;
Figueroa, R. ;
Pena, G. .
CORROSION SCIENCE, 2012, 54 :143-152
[2]   Investigation on the tribology of Zr ion implanted tool steel [J].
Akbas, N ;
Oztarhan, A ;
Monteiro, OR ;
Brown, IG .
WEAR, 2002, 252 (7-8) :540-545
[3]   Effect of ion implantation on the tribology of metal-on-metal hip prostheses [J].
Bowsher, JG ;
Hussain, A ;
Williams, P ;
Nevelos, J ;
Shelton, JC .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :107-111
[4]   Hardness of Multi Wall Carbon Nanotubes reinforced aluminium matrix composites [J].
Bradbury, Christopher R. ;
Gomon, Jaana-Kateriina ;
Kollo, Lauri ;
Kwon, Hansang ;
Leparoux, Marc .
JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 585 :362-367
[5]   Comparison of the oxidation resistances of yttrium implanted low manganese and low manganese-carbon steels at high temperature [J].
Caudron, E ;
Buscail, H .
APPLIED SURFACE SCIENCE, 2000, 158 (3-4) :310-329
[6]   Effect of MEVVA ion implantation on fatigue properties of TC18 titanium alloy [J].
Chen, Xiaohu ;
Soveja, Adriana ;
Chaussumier, Michel ;
Zhang, Pingze ;
Wei, Dongbo ;
Ding, Feng .
SURFACE & COATINGS TECHNOLOGY, 2018, 344 :572-578
[7]   Effects of carbon addition on wear mechanisms of CoCrMo metal-on-metal hip joint bearings [J].
Chen, Yan ;
Li, Yunping ;
Koizumi, Yuichiro ;
Haider, Hani ;
Chiba, Akihiko .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 76 :997-1004
[8]  
Cullity B.D., 1978, ELEMENTS XRAY DIFFRA, V2nd, P102
[9]  
Danaila E, 2016, E HLTH BIOENG C, P1
[10]   The microstructure, mechanical and tribological properties of TiN coatings after Nb and C ion implantation [J].
Deng, Bin ;
Tao, Ye ;
Hu, Zhijie .
APPLIED SURFACE SCIENCE, 2013, 284 :405-411