Treatment of Orbital Blowout Fracture Using Porous Polyethylene With Embedded Titanium

被引:5
作者
Qian, Zhuyun [1 ]
Zhuang, Ai [1 ]
Lin, Ming [1 ]
Li, Zhengkang [1 ]
Ge, Shengfang [1 ]
Fan, Xianqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Peoples Hosp 9, Dept Ophthalmol, Shanghai 200011, Peoples R China
关键词
Orbital blowout fracture; surgical repair; porous polyethylene with embedded titanium; RECONSTRUCTION; IMPLANT;
D O I
10.1097/SCS.0000000000001407
中图分类号
R61 [外科手术学];
学科分类号
摘要
The study was performed to evaluate the effectiveness and safety of porous polyethylene with embedded titanium in the repair of orbital blowout fracture. The study was designed as a prospective case series. Patients who were diagnosed with orbital blowout fracture from May 2012 to March 2013 were included in the study. A composite material of porous polyethylene and titanium mesh was used. Orbital volumes before and after surgery were measured, and the results of diplopia and ocular movement were recorded. The occurrence of diplopia was grouped and compared according to the time interval between injury and surgery. The incidence of other complications was also recorded. A total of 26 patients were involved in the study. The minimal follow-up time was 12 months. All surgeries were performed uneventfully. The orbital volume significantly decreased after the surgery, and the remission rate and the elimination rate of diplopia in 12 months were 85.7% and 47.6%, respectively. Postoperative diplopia was correlated with the time interval between injury and surgery. One patient presented with undercorrection of enophthalmos, and another patient presented with acute aggravation of diplopia and exophthalmos after surgery, which was resolved with treatment. In conclusion, porous polyethylene with embedded titanium was effective and safe in the repair of orbital blowout fracture, and studies with more subjects and longer follow-up period are recommended in future studies.
引用
收藏
页码:569 / 572
页数:5
相关论文
共 18 条
[1]   Materials Used for Reconstruction After Orbital Floor Fracture [J].
Avashia, Yash J. ;
Sastry, Ananth ;
Fan, Kenneth L. ;
Mir, Haaris S. ;
Thaller, Seth R. .
JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 :1991-1997
[2]   Comparing the osteogenic capacities of bone substitutes: Hydroxyapatite, high-density porous polyethylene, and bone collagen: A biochemical and histological analysis [J].
Bilkay, U ;
Alper, M ;
Celik, N ;
Erdem, O ;
Kerem, H ;
Ozek, C ;
Zekioglu, O ;
Delen, Y ;
Songur, E ;
Cagdas, A .
JOURNAL OF CRANIOFACIAL SURGERY, 2004, 15 (04) :585-593
[3]  
Burnstine Michael A, 2003, Curr Opin Ophthalmol, V14, P236, DOI 10.1097/00055735-200310000-00002
[4]   Orbital Blowout Fractures and Race [J].
de Silva, Don Julian ;
Rose, Geoffrey E. .
OPHTHALMOLOGY, 2011, 118 (08) :1677-1680
[5]   Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh [J].
Ellis, E ;
Tan, YH .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (04) :442-453
[6]   Treatment of orbital fractures: The case for treatment with resorbable materials [J].
Enislidis, G .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (07) :869-872
[7]   Long-term sequelae after surgery for orbital floor fractures [J].
Folkestad, L ;
Westin, T .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 120 (06) :914-921
[8]   Use of porous polyethylene with embedded titanium in orbital reconstruction: A review of 106 patients [J].
Garibaldi, Daniel C. ;
Nicholas, T. Iliff ;
Grant, Michael P. ;
Merbs, Shannath L. .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (06) :439-444
[9]   Management of Orbital Reconstruction [J].
Goiato, Marcelo Coelho ;
Demathe, Adriana ;
Suzuki, Thais ;
dos Santos, Daniela Micheline ;
de Carvalho Dekon, Stefan Fiuza .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (06) :1834-1836
[10]   Biomaterials for Repair of Orbital Floor Blowout Fractures: A Systematic Review [J].
Gunarajah, Dharmindra Rajah ;
Samman, Nabil .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) :550-570