An Analysis of the Utility of Handheld PET Probes for the Intraoperative Localization of Malignant Tissue

被引:9
作者
Gonzalez, Segundo Jaime [1 ]
Gonzalez, Lorena [1 ]
Wong, Joyce [1 ]
Brader, Peter [2 ]
Zakowski, Maureen [3 ]
Goenen, Mithat [4 ]
Daghighian, Farhad [5 ]
Fong, Yuman [1 ]
Strong, Vivian E. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10065 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10065 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, New York, NY 10065 USA
[5] IntraMed Imaging LLC, Los Angeles, CA USA
关键词
PET probe; Minimally invasive surgery; Intraoperative probe; Beta rays; High-energy gamma rays; POSITRON-EMISSION-TOMOGRAPHY; NUDE RAT MODEL; FDG-PET; ESOPHAGEAL; RECURRENT; CANCER; IMPACT;
D O I
10.1007/s11605-010-1394-5
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The intraoperative localization of suspicious lesions detected by positron emission tomography (PET) scan remains a challenge. To solve this, two novel probes have been created to accurately detect the F-18-FDG radiotracer intraoperatively. Nude rats were inoculated with mesothelioma. When PET scans detected 10-mm tumors, animals were dissected and the PET probes analyzed the intraoperative radiotracer uptake of these lesions as tumor to background ratio (TBR). The 17 suspicious lesions seen on PET scan were localized intraoperatively (by their high TBR) using the PET probes and found malignant on pathology. Interestingly, smaller tumors not visualized on PET scan were detected intraoperatively by their high TBR and found malignant on pathology. Furthermore, using a TBR threshold as low as 2.0, both gamma (sensitivity, 100%; specificity, 80%; positive predictive value (PPV), 96%; and negative predictive value (NPV), 100%) and beta (sensitivity, 100%; specificity, 60%; PPV, 93%; and NPV, 100%) probes reliably detected suspicious lesions on PET scan imaging. They also showed an excellent area under the curve of 0.9 and 0.97 (95% CI of 0.81-0.99 and 0.93-1.0) for gamma and beta probes, respectively, in the receiver operating characteristic analysis for detecting malignancy. This novel tool could be used synergistically with a PET scan imaging to maximize tissue selection intraoperatively.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 24 条
[11]  
HOWARD RB, 1991, CANCER RES, V51, P3274
[12]   PET imaging in assessing gastrointestinal tumors [J].
Hustinx, R .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (06) :1123-+
[13]   Advances in metabolic imaging for surgical oncology [J].
Iagaru, Andrei ;
Quon, Andrew .
SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2007, 16 (02) :273-+
[14]   NUDE RAT MODEL FOR STUDYING METASTASIS OF HUMAN TUMOR-CELLS TO BONE AND BONE-MARROW [J].
KJONNIKSEN, I ;
NESLAND, JM ;
PIHL, A ;
FODSTAD, O .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1990, 82 (05) :408-412
[15]   PET imaging in gynecologic malignancies [J].
Kumar, R ;
Alavi, A .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (06) :1155-+
[16]   Factors influencing change of preoperative treatment intent in a gastrointestinal cancer practice [J].
Schwarz R.E. .
World Journal of Surgical Oncology, 5 (1)
[17]  
SHELDON C, 1952, CANCER RES, V12, P909
[18]  
Siggelkow W, 2004, EUR J NUCL MED MOL I, V31, pS118
[19]   A novel method to localize antibody-targeted cancer deposits intraoperatively using handheld PET beta and gamma probes [J].
Strong, Vivian E. ;
Humm, John ;
Russo, Paul ;
Jungbluth, Achim ;
Wong, W. Douglas ;
Daghighian, Farhad ;
Old, Lloyd ;
Fong, Yuman ;
Larson, Steven M. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (02) :386-391
[20]   Systematic review of the staging performance of 18F-fluorodeoxyglucose positron emission tomography in esophageal cancer [J].
van Westreenen, HL ;
Westerterp, M ;
Bossuyt, PMM ;
Pruim, J ;
Sloof, GW ;
van Lanschot, JJB ;
Groen, H ;
Plukker, JTM .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (18) :3805-3812