AC biased TES-based X-ray microcalorimeter with an energy resolution of 6.3 eV at 5.89 keV

被引:7
作者
van der Kuur, J [1 ]
de Korte, PAJ
Hoevers, HFC
Tiest, WMB
Baars, NHR
Ridder, ML
Krouwer, E
Bruijn, MP
Kiviranta, M
Seppä, H
机构
[1] SRON, Natl Inst Space Res, NL-3584 CA Utrecht, Netherlands
[2] VTT Microsensing, Espoo 02150, Finland
关键词
D O I
10.1109/TASC.2003.813980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency domain multiplexing (FDM) is an attractive option for the readout of imaging arrays of microcalorimeters. The most straightforward implementation of FDM is based on alternating voltage (AC) biasing of the individual microcalorimeters. It is clear that for future applications the performance in terms of energy resolution and count rate capability is crucial. We discuss the consequences of AC bias for the performance of a microcalorimeter, and make a direct experimental comparison between the performance of a TES based microcalorimeter AC and DC bias. Modeling, as well as experiments, show that the performance of the device is is very similar in terms of energy resolution and pulse shapes (100 mus effective time constant). The measured energy resolution at 5.89 keV photon energy is 6.3 eV for AC bias at 46 kHz and 5.5 eV for DC bias.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 12 条
  • [1] High-resolution operation of frequency-multiplexed transition-edge photon sensors
    Cunningham, MF
    Ullom, JN
    Miyazaki, T
    Labov, SE
    Clarke, J
    Lanting, TM
    Lee, AT
    Richards, PL
    Yoon, J
    Spieler, H
    [J]. APPLIED PHYSICS LETTERS, 2002, 81 (01) : 159 - 161
  • [2] Cryogenic imaging spectrometers for X-ray astronomy
    de Korte, PAJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) : 163 - 169
  • [3] K alpha(1,2) and K beta(1,3) x-ray emission lines of the 3d transitions metals
    Holzer, G
    Fritsch, M
    Deutsch, M
    Hartwig, J
    Forster, E
    [J]. PHYSICAL REVIEW A, 1997, 56 (06): : 4554 - 4568
  • [4] A Mo-Cu superconducting transition-edge microcalorimeter with 4.5 eV energy resolution at 6 keV
    Irwin, KD
    Hilton, GC
    Martinis, JM
    Deiker, S
    Bergren, N
    Nam, SW
    Rudman, DA
    Wollman, DA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) : 184 - 187
  • [5] AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION
    IRWIN, KD
    [J]. APPLIED PHYSICS LETTERS, 1995, 66 (15) : 1998 - 2000
  • [6] SQUID multiplexers for transition-edge sensors
    Irwin, KD
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 368 (1-4): : 203 - 210
  • [7] Kiviranta M, 2002, AIP CONF PROC, V605, P295, DOI 10.1063/1.1457649
  • [8] KIVIRANTA M, 2002, P FAR IR SUB MM MM D
  • [9] PORTER F, 2001, AIP C P LTD 9, V605
  • [10] Tiest WMB, 2002, AIP CONF PROC, V605, P199, DOI 10.1063/1.1457627