Investigation of the technical and physical properties of metal composite 1x1 rib knitted fabrics

被引:13
作者
Ilkan, Ozkan [1 ]
机构
[1] Univ Cukurova, Fac Engn, Text Engn Dept, TR-01360 Adana, Turkey
来源
INDUSTRIA TEXTILA | 2020年 / 71卷 / 01期
关键词
composite yarns; composite fabric; knitted fabric; physical properties; technical properties; ELECTROMAGNETIC SHIELDING EFFECTIVENESS; WOVEN FABRICS; MECHANICAL-PROPERTIES; HYBRID YARNS; MICROSTRUCTURE; DISPERSION; EFFICIENCY; SINGLE; COPPER;
D O I
10.35530/IT.071.01.1693
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In this study, it was aimed to determine electromagnetic shielding effectiveness, antibacterial activity, surface resistivity and bending rigidity properties of 1x1 rib knitted fabrics. For this purpose, copper (Cu), stainless steel (SS) and silver (Ag) wires were commingled with two nylon filaments to produce metal composite yarns. 1x1 rib fabrics were produced by these composite yarns. Electromagnetic shielding effectiveness (EMSE), antibacterial activity, surface resistivity and bending rigidity of the composite knits were measured. Electromagnetic shielding measurements of samples were conducted between 1.0-5.0 GHz frequency. Antibacterial activity test was applied according to AATCC 100 standard against K. pneumoniae and S. aureus bacteria. Results showed that knitted fabrics generally have lower SE values than 10 dB at wale direction. The double layer samples provide higher EMSE than single layer samples for all metal types. Maximum EMSE value was obtained as 57.12 dB. The use of metal wire significantly reduced surface resistivity of knitted fabrics. Copper composite knitted fabrics showed 99 % antibacterial activity against both bacterial species. When compared to the control sample, the use of metal wire significantly increased the rigidity of the samples.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 40 条
[1]   Electromagnetic shielding characterization of conductive knitted fabrics [J].
Abdulla, Ruslan ;
Delihasanlar, Ediz ;
Abdulla, Fidan Gamze Kizilcay ;
Yuzer, Ahmet Hayrettin .
Progress In Electromagnetics Research M, 2017, 56 :33-41
[2]   Electromagnetic interference shielding mechanisms of CNT/polymer composites [J].
Al-Saleh, Mohammed H. ;
Sundararaj, Uttandaraman .
CARBON, 2009, 47 (07) :1738-1746
[3]   An alternative approach to design conductive hybrid cover yarns for efficient electromagnetic shielding fabrics [J].
Asghar, A. ;
Ahmad, M. R. ;
Yahya, M. F. ;
Ali, M. T. ;
Ab Aziz, A. A. ;
Rahman, N. H. Abd ;
Ul Hassan, S. Zameer ;
Kashif, M. .
JOURNAL OF INDUSTRIAL TEXTILES, 2018, 48 (01) :38-57
[4]   Investigation of electrical, electromagnetic shielding, and usage properties of woven fabrics made from different hybrid yarns containing stainless steel wires [J].
Bedeloglu, Ayse .
JOURNAL OF THE TEXTILE INSTITUTE, 2013, 104 (12) :1359-1373
[5]  
Çeken F, 2011, TEKSTIL, V60, P321
[6]   The electromagnetic shielding properties of some conductive knitted fabrics produced on single or double needle bed of a flat knitting machine [J].
Ceken, Fatma ;
Kayacan, Ozlem ;
Ozkurt, Ahmet ;
Ugurlu, Sebnem Seckin .
JOURNAL OF THE TEXTILE INSTITUTE, 2012, 103 (09) :968-979
[7]   Fabrication of conductive woven fabric and analysis of electromagnetic shielding via measurement and empirical equation [J].
Chen, H. C. ;
Lee, K. C. ;
Lin, J. H. ;
Koch, A. .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2007, 184 (1-3) :124-130
[8]   Electromagnetic interference shielding effectiveness of carbon materials [J].
Chung, DDL .
CARBON, 2001, 39 (02) :279-285
[9]  
Djokic S., 2008, ECS Transactions, V11, P1, DOI [10.1149/1.2928902, DOI 10.1149/1.2928902]
[10]   Electromagnetic shielding effectiveness of woven fabrics containing cotton/metal-wrapped hybrid yarns [J].
Erdumlu, Nazan ;
Saricam, Canan .
JOURNAL OF INDUSTRIAL TEXTILES, 2016, 46 (04) :1084-1103