Does thoracic bioimpedance accurately determine cardiac output in COPD patients during maximal or intermittent exercise?

被引:48
作者
Bougault, V [1 ]
Lonsdorfer-Wolf, E [1 ]
Charloux, A [1 ]
Richard, R [1 ]
Geny, B [1 ]
Oswald-Mammosser, M [1 ]
机构
[1] Univ Hosp Strasbourg, Dept Resp Cardiocirculatory & Exercise Physiol, Strasbourg, France
关键词
cardiac output; COPD; exercise; Fick principle; impedance cardiography;
D O I
10.1378/chest.127.4.1122
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: The monitoring of cardiac output (CO) during exercise rehabilitation in patients with COPD, often including strenuous exercise, is advisable. Invasive methods (thermodilution, Fick method) are accurate, but for clinical routine use noninvasive CO estimation is required. We have shown that impedance cardiography (Physio Flow; Manatee Biomedical; Macheren, France) is reliable in COPD patients at rest and during a recumbent, light-intensity exercise. The aim of our study was to evaluate the validity of this noninvasive device in COPD patients during a maximal incremental exercise test (IET) and also during a strenuous intermittent work exercise test (IWET). Design: Prospective comparative study of the impedance cardiograph vs the direct Fick method applied to oxygen. Patients: Eight patients with moderate-to-severe COPD (59 +/- 6 years old; FEV1, 38 +/- 15% predicted; residual volume, 194 +/- 64% predicted) [mean +/- SD]. Measurements and main results: Forty-nine simultaneous measurements of CO by means of the direct Fick method (COFICK) and CO measured by the impedance cardiograph (COPF) were obtained during the IET, and 108 measurements were made during the IWET. The correlation coefficients between the two measurements were r = 0.85 and r = 0.71 for the IET and the IWET, respectively. COPF was higher than COFICK. The difference between the two methods was 3.2 +/- 2.9 L/min during the IET and 2.5 +/- 2.1 L/min during the IWET. Expressed as a percentage of the mean of the two measurements, this corresponded to 31 +/- 21% and 25 +/- 20%, respectively. Conclusions: The relatively high number of values differing by > 20% precludes the use of impedance cardiography in clinical routine in such a difficult setting (hyperinflated patients and intense exercise).
引用
收藏
页码:1122 / 1131
页数:10
相关论文
共 41 条
  • [21] Resting handgrip force and impaired cardiac function at rest and during exercise in COPD patients
    Cortopassi, Felipe
    Divo, Miguel
    Pinto-Plata, Victor
    Celli, Bartolome
    RESPIRATORY MEDICINE, 2011, 105 (05) : 748 - 754
  • [22] On- and off-exercise kinetics of cardiac output in response to cycling and walking in COPD patients with GOLD Stages I-IV
    Vasilopoulou, M. K.
    Vogiatzis, I.
    Nasis, I.
    Spetsioti, S.
    Cherouveim, E.
    Koskolou, M.
    Kortianou, E. A.
    Louvaris, Z.
    Kaltsakas, G.
    Koutsoukou, A.
    Koulouris, N. G.
    Alchanatis, M.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2012, 181 (03) : 351 - 358
  • [23] RETRACTED ARTICLE: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution
    Stefan Suttner
    Thilo Schöllhorn
    Joachim Boldt
    Jochen Mayer
    Kerstin D. Röhm
    Katrin Lang
    Swen N. Piper
    Intensive Care Medicine, 2006, 32 : 2053 - 2058
  • [24] Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects
    Alessio del Torto
    Øyvind Skattebo
    Jostein Hallén
    Carlo Capelli
    European Journal of Applied Physiology, 2019, 119 : 163 - 170
  • [25] Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Doutreleau, S
    Buchheit, M
    Oswald-Mammosser, M
    Lampert, E
    Mettauer, B
    Geny, B
    Lonsdorfer, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 85 (3-4) : 202 - 207
  • [26] Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects
    del Torto, Alessio
    Skattebo, Oyvind
    Hallen, Jostein
    Capelli, Carlo
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (01) : 163 - 170
  • [27] Maximum heart rate does not limit cardiac output at rest or during exercise in the American alligator (Alligator mississippiensis)
    Joyce, William
    Elsey, Ruth M.
    Wang, Tobias
    Crossley, Dane A.
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2018, 315 (02) : R296 - R302
  • [28] Relationship between impaired chronotropic response, cardiac output during exercise, and exercise tolerance in patients with chronic heart failure
    Samejima, H
    Omiya, K
    Uno, M
    Inoue, K
    Tamura, M
    Itoh, K
    Suzuki, K
    Akashi, Y
    Seki, A
    Suzuki, N
    Osada, N
    Tanabe, K
    Miyake, F
    Itoh, H
    JAPANESE HEART JOURNAL, 2003, 44 (04): : 515 - 525
  • [29] Does airflow limitation severity in stable condition severity of COPD influences in patient cardiac autonomic modulation in COPD patients during hospitalization for exacerbation?
    Schafauser, Nathany Souza
    De Oliveira Kawakami, Debora Mayumi
    Heubel, Alessandro Domingues
    Kabbach, Erika Zavaglia
    Sgarbosa, Nicole Marques
    Pires Di-Lorenzo, Valeria Amorim
    Borghi-Silva, Audrey
    Mendes, Renata Goncalves
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [30] Determination of cardiac output during mechanical ventilation by electrical bioimpedance or thermodilution in patients with acute lung injury: Effects of positive end-expiratory pressure
    Genoni, M
    Pelosi, P
    Romand, JA
    Pedoto, A
    Moccetti, T
    Malacrida, R
    CRITICAL CARE MEDICINE, 1998, 26 (08) : 1441 - 1445