STUDY OF THERMAL RADIATION SHIELDS FOR THE ILC CRYOMODULE

被引:8
作者
Ohuchi, N. [1 ]
Arkan, T. [2 ]
Barbanotti, S. [2 ]
Carter, H. [2 ]
Kerby, J. [2 ]
Nakai, H. [1 ]
Pagani, C. [3 ]
Peterson, T. J. [2 ]
Pierini, P. [3 ]
Tsuchiya, K. [1 ]
Yamamoto, A. [1 ]
Zong, Z. [1 ]
机构
[1] High Energy Accelerator Res Org, KEK, Tsukuba, Ibaraki 3050801, Japan
[2] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[3] Ist Nazl Fis Nucl LASA, I-20090 Milan, Italy
来源
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B | 2012年 / 1434卷
关键词
ILC cryomodule; 5 K thermal shield; thermal radiation;
D O I
10.1063/1.4707009
中图分类号
O59 [应用物理学];
学科分类号
摘要
The main linacs of the International Linear Collider are composed of 1824 cryomodules. As part of the R&D on the cryomodule, simplifications of the design were considered to reduce the construction and installation costs, including the possibility of removing a portion of the 5 K thermal shield. For this investigation the heat load measurements of a 6 meter cryomodule with and without the 5 K shield were performed, and used to determine emissivity coefficients. A thermal model of a full cryomodule was then created, and the heat loads of the cryomodule with the full set of the 5 K shield and without the lower 5 K shield were calculated with these parameters. By using a modified cooling scheme for the high temperature thermal shielding, we showed that the heat loads at 2 K between two models are substantially equivalent, and indeed, the thermal model without the 5 K lower shield requires 2% less work from the refrigerator.
引用
收藏
页码:929 / 936
页数:8
相关论文
共 8 条
[1]  
[Anonymous], 2007, ILC REFERENCE DESIGN, V3, pIII
[2]  
Corruccini R., 1960, NBS MONOGRAPH, P7
[3]  
Dohlus M, 2004, P LINAC 2004 LUB GER, P174
[4]  
Hands B.A, 1986, CRYOGENIC ENG, P107
[5]  
Ohuchi N, 2010, P INT CRYOG ENG C WR
[6]  
Ohuchi N, 2008, P 11 EUR PART ACC C, P892
[7]  
Pagani C., 200136 TESLA
[8]  
Peterson T, 2008, TILC08 SEND