Autologous Neurosensory Retinal Transplantation for Unclosed and Large Macular Holes

被引:22
|
作者
Ding, Chun [1 ]
Li, Shengguo [1 ]
Zeng, Jun [1 ]
机构
[1] Cent S Univ, Xiangya Hosp 2, Dept Ophthalmol, 139 Renmin Middle Rd, Changsha 410011, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Macular hole; Autologous neurosensory retinal transplantation; Vitrectomy; Internal limiting membrane; INTERNAL-LIMITING MEMBRANE; OPTICAL COHERENCE TOMOGRAPHY; INDOCYANINE GREEN; SURGERY; VITRECTOMY; CLOSURE; FLAP;
D O I
10.1159/000487952
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to demonstrate the surgical technique and clinical outcome of autologous neurosensory retinal patch transplantation for recurrent large macular hole (MH)-induced retinal detachment after failed surgery with internal limiting membrane (ILM) removal or transplantation. Methods: We reviewed 5 patients with recurrent MH-induced retinal detachment after failed surgeries with ILM removal or transplantation who underwent vitrectomy combined with autologous neurosensory retinal patch transplantations and were followed up over 6 months. In the autologous neurosensory retinal patch transplantation procedure, a small piece of neurosensory retina was removed and transplanted inside the MH. The anatomic outcomes of MH-induced retinal detachment were evaluated by fundus examinations and optical coherence tomography. The preoperative and postoperative best-corrected visual acuities (BCVAs) were compared and the MH closure rates were measured as the main outcomes. Results: A total of 5 patients (3 men and 2 women; average age 35.4 +/- 18.72 years) were included in our study. Complete MH sealing was achieved in 5 eyes after autologous neurosensory retinal patch transplantations, and no complications were observed. The mean BCVA was 2.38 +/- 0.57 (range 1.6-3) before surgery, and 1.46 +/- 0.51 (range 1-2) at 6 postoperative months. There was a significant difference in BCVA before versus after the surgery (p < 0.05, paired t test). Conclusions: Autologous neurosensory retinal patch transplantation is an effective addition to the surgical options for large MH-induced retinal detachment after failed surgery with ILM removal or transplantation. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [1] Retinal Morphologic Features in Patients with Large Macular Holes Treated by Autologous Neurosensory Retinal Transplantation
    Kitahata, Shohei
    Inoue, Tatsuya
    Nagura, Koichi
    Nakamura, Kentaro
    Tanaka, Shin
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY RETINA, 2023, 7 (05): : 406 - 412
  • [2] Autologous neurosensory retinal transplantation Case report and a brief overview of macular hole surgery
    Bokor, Adam
    Makhoul, Sara
    Pasztor, Orsolya
    Fodor, Mariann
    ORVOSI HETILAP, 2023, 164 (38) : 1511 - 1517
  • [3] MANAGEMENT OF REFRACTORY LARGE MACULAR HOLE WITH AUTOLOGOUS NEUROSENSORY RETINAL FREE FLAP TRANSPLANTATION
    Chang, Yo-Chen
    Liu, Pei-Kang
    Kao, Tzu-En
    Chen, Kuo-Jen
    Chen, Yi-Hsien
    Chiu, Wei-Jun
    Wu, Kwou-Yeung
    Wu, Wen-Chuan
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (11): : 2134 - 2139
  • [4] AUTOLOGOUS RETINAL TRANSPLANTATION AS A PRIMARY TREATMENT FOR LARGE CHRONIC MACULAR HOLES
    Tanaka, Shin
    Inoue, Maiko
    Inoue, Tatsuya
    Yamakawa, Tadashi
    Uchio, Eiichi
    Grewal, Dilraj S.
    Mahmoud, Tamer H.
    Kadonosono, Kazuaki
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (10): : 1938 - 1945
  • [5] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Kenan Sonmez
    International Ophthalmology, 2021, 41 : 1415 - 1425
  • [6] Autologous neurosensory retinal transplantation for large refractory idiopathic macular hole
    Sonmez, Kenan
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (04) : 1415 - 1425
  • [7] Internal limiting membrane transplantation for unclosed and large macular holes
    Dai, Yining
    Dong, Fangtian
    Zhang, Xiao
    Yang, Zhikun
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (11) : 2095 - 2099
  • [8] INTRAOPERATIVE AND POSTOPERATIVE MONITORING OF AUTOLOGOUS NEUROSENSORY RETINAL FLAP TRANSPLANTATION FOR A REFRACTORY MACULAR HOLE ASSOCIATED WITH HIGH MYOPIA
    Takeuchi, Jun
    Kataoka, Keiko
    Shimizu, Hideyuki
    Tomita, Ryo
    Kominami, Taro
    Ushida, Hiroaki
    Kaneko, Hiroki
    Ito, Yasuki
    Terasaki, Hiroko
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (05): : 921 - 930
  • [9] Autologous neurosensory retinal transplantation for recurrent macular hole retinal detachment in highly myopic eyes
    Li, Yanzi
    Li, Zhaohui
    Xu, Changzhong
    Liu, Yong
    Kang, Xueqin
    Wu, Jianhua
    ACTA OPHTHALMOLOGICA, 2020, 98 (08) : E983 - E990
  • [10] Autologous Neurosensory Retinal Free Flap Treatment for a Large Macular Hole
    Lazic, Ratimir
    Draca, Natasa
    Cerovic, Vesna
    Katic, Dinko
    Mladenovski, Stefan
    Gabric, Nikica
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (09) : E89 - E92