摘要
Purpose: The choice of vascular access catheter may affect filter life during continuous renal replacement therapy (CRRT); specifically, a new surface-modified catheter has been reported to possibly prevent thrombosis and catheter malfunction. Design and setting: A sequential, controlled study in a tertiary ICU. Aims: To compare circuit life when CRRT was performed with a Bard (R) Niagara (TM) catheter or the surface-modified GamCath (TM) Dolphin (R) Protect 1320 catheter. Patients and measurements: We studied 50 patients with acute kidney injury requiring CRRT, all delivered with catheters in the femoral position. We obtained information on age, gender, disease severity score (APACHE II and APACHE III), filter life, total heparin dose, hemoglobin concentration, platelet count, INR, and aPTT during CRRT. Results: We studied 341 circuits in 50 patients; 30 patients (140 circuits) used the Niagara and 20 patients (201 circuits) used the Dolphin catheter. Mean of circuit life in two groups was 14.9 hours and 13.1 hours, respectively (p=0.22). Patients using Niagara catheters had a more prolonged APTT (p<0.01) and lower platelet count (p=0.05), while heparin dose (p=0.22), and other anticoagulant treatment (p=0.73) were not significantly different. On Kaplan-Meier survival analysis, circuit life was not significant different between the two catheters (p=0.15). Conclusions: The Niagara and Dolphin catheters appear to be broadly equivalent in terms of their impact on circuit life.
引用
收藏
页码:1061 / 1066
页数:6
相关论文
共 24 条
[1]   Prolonged catheter survival in intermittent hemodialysis using a less thrombogenic micropatterned polymer modification [J].
Baumann, M ;
Witzke, O ;
Dietrich, R ;
Haug, U ;
Deppisch, R ;
Lutz, J ;
Philipp, T ;
Heemann, U .
ASAIO JOURNAL, 2003, 49 (06) :708-712
[2]  
Bellomo R, 2009, NEW ENGL J MED, V361, P1627, DOI 10.1056/NEJMoa0902413
[3]   Physical and biological effects of a surface coating procedure on polyurethane catheters [J].
Francois, P ;
Vaudaux, P ;
Nurdin, N ;
Mathieu, HJ ;
Descouts, P ;
Lew, DP .
BIOMATERIALS, 1996, 17 (07) :667-678
[4]   Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin [J].
Grudzinski, Linda ;
Quinan, Patricia ;
Kwok, Sophie ;
Pierratos, Andreas .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (02) :471-476
[5]   Correlates of vascular access and nonvascular access-related hospitalizations in hemodialysis patients [J].
Ifudu, O ;
Mayers, JD ;
Cohen, LS ;
Paul, H ;
Brezsnyak, WF ;
Avram, MM ;
Herman, AI ;
Friedman, EA .
AMERICAN JOURNAL OF NEPHROLOGY, 1996, 16 (02) :118-123
[6]   Prolonged catheter survival in patients with acute kidney injury on continuous renal replacement therapy using a less thrombogenic micropatterned polymer modification [J].
Meier, Pascal ;
Meier, Rachel ;
Turini, Pierre ;
Friolet, Raymond ;
Blanc, Edouard .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (02) :628-635
[7]   Resistance of vascular access catheters for continuous renal replacement therapy: An ex vivo evaluation [J].
Naka, T. ;
Egi, M. ;
Bellomo, R. ;
Baldwin, I. ;
Fealy, N. ;
Wan, L. .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (10) :905-909
[8]   Catheter patency and function after catheter sheath disruption: A pilot study [J].
Oliver, Matthew J. ;
Mendelssohn, David C. ;
Quinn, Robert R. ;
Richardson, Elizabeth P. ;
Rajan, Deeraj K. ;
Pugash, Robyn A. ;
Hiller, Joyce A. ;
Kiss, Alex J. ;
Lok, Charmaine E. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (06) :1201-1206
[9]   Antimicrobial-coated/bonded and -impregnated intravascular catheters [J].
Pai, MP ;
Pendland, SL ;
Danziger, LH .
ANNALS OF PHARMACOTHERAPY, 2001, 35 (10) :1255-1263
[10]   Femoral vs jugular venous catheterization and risk of nosocomial events in adults requiring acute renal replacement therapy -: A randomized controlled trial [J].
Parienti, Jean-Jacques ;
Thirion, Marina ;
Megarbane, Bruno ;
Souweine, Bertrand ;
Ouchikhe, Abdelali ;
Polito, Andrea ;
Forel, Jean-Marie ;
Marque, Sophie ;
Misset, Benoit ;
Airapetian, Norair ;
Daurel, Claire ;
Mira, Jean-Paul ;
Ramakers, Michel ;
du Cheyron, Damien ;
Le Coutour, Xavier ;
Daubin, Cedric ;
Charbonneau, Pierre .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (20) :2413-2422