Minimally invasive laser vibrometry (MIVIB) with a floating mass transducer - A new method for objective evaluation of the middle ear demonstrated on stapes fixation

被引:6
|
作者
Wales, Jeremy [1 ]
Gladine, Kilian [2 ]
Van de Heyning, Paul [3 ]
Topsakal, Vedat [3 ]
von Unge, Magnus [4 ,5 ]
Dirckx, Joris [2 ]
机构
[1] Karolinska Univ Hosp, Dept Otorhinolaryngol, S-18146 Stockholm, Sweden
[2] Univ Antwerp, Lab Biomed Phys, Antwerp, Belgium
[3] Univ Antwerp, Antwerp Univ Hosp, Dept Otorhinolaryngol & Head & Neck Surg, Antwerp, Belgium
[4] Akershus Univ Hosp, Dept Otorhinolaryngol, Oslo, Norway
[5] Univ Oslo, Oslo, Norway
关键词
Hearing loss; Otitis media; Otosclerosis; Laser vibrometry; Floating mass transducer; HUMAN TEMPORAL BONES; OSSICULAR FIXATION; DIAGNOSTIC-TOOL; PREVALENCE; OSSICLES; VIBRATION; EARDRUM; ADULTS; SYSTEM; CHAIN;
D O I
10.1016/j.heares.2017.11.007
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Ossicular fixation through otosclerosis, chronic otitis media and other pathologies, especially tympanosclerosis, are treated by surgery if hearing aids fail as an alternative. However, the best hearing outcome is often based on knowledge of the degree and location of the fixation. Objective methods to quantify the degree and position of the fixation are largely lacking. Laser vibrometry is a known method to detect ossicular fixation but clinical applicability remains limited. A new method, minimally invasive laser vibrometry (MIVIB), is presented to quantify ossicle mobility using laser vibrometry measurement through the ear canal after elevating the tympanic membrane, thus making the method feasible in minimally invasive explorative surgery. A floating mass transducer provides a clinically relevant transducer to drive ossicular vibration. This device was attached to the manubrium and drove vibrations at the same angle as the longitudinal axis of the stapes and was therefore used to assess ossicular chain mobility in a fresh-frozen temporal bone model with and without stapes fixation. The ratio between the umbo and incus long process was shown to be useful in assessing stapes fixation. The incus-to-umbo velocity ratio decreased by 15 dB when comparing the unfixated situation to stapes fixation up to 2.5 kHz. Such quantification of ossicular fixation using the incus-to-umbo velocity ratio would allow quick and objective analysis of ossicular chain fixations which will assist the surgeon in surgical planning and optimize hearing outcomes. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 5 条
  • [1] Evaluation of Artificial Fixation of the Incus and Malleus With Minimally Invasive Intraoperative Laser Vibrometry (MIVIB) in a Temporal Bone Model
    Gladine, Kilian
    Wales, Jeremy
    Silvola, Juha
    Muyshondt, Pieter G. G.
    Topsakal, Vedat
    De Heyning, Paul Van
    Dirckx, Joris J. J.
    von Unge, Magnus
    OTOLOGY & NEUROTOLOGY, 2020, 41 (01) : 45 - 51
  • [2] Evaluation of a differential floating mass type transducer for a middle ear implant system
    Song, BS
    Kim, MN
    Park, SK
    Lee, SH
    Cho, JH
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 577 - 580
  • [3] Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer
    Boehnke, Frank
    Bretan, Theodor
    Lehner, Stefan
    Strenger, Tobias
    MATERIALS, 2013, 6 (10): : 4675 - 4688
  • [4] Magnetically driven middle ear ossicles with laser vibrometry as a new diagnostic tool to quantify ossicular fixation
    Peacock, John
    Dirckx, Joris
    von Unge, Magnus
    ACTA OTO-LARYNGOLOGICA, 2014, 134 (04) : 352 - 357
  • [5] A new minimally invasive method for the transtubal, microendoscopic application of fluids to the middle ear
    Todt, Ingo
    Seidl, Rainer
    Ernst, Arne
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2008, 17 (05) : 300 - 302