High-resolution impedance manometry parameters in the evaluation of esophageal function of non-obstructive dysphagia patients

被引:16
作者
Singendonk, Maartje J. [1 ]
Lin, Zhiyue [2 ]
Scheerens, Charlotte [3 ,4 ]
Tack, Jan [4 ]
Carlson, Dustin A. [2 ]
Omari, Taher, I [3 ,5 ]
Pandolfino, John E. [2 ]
Rommel, Nathalie [3 ,4 ]
机构
[1] Amsterdam UMC, Emma Childrens Hosp, Dept Pediat Gastroenterol & Nutr, Amsterdam, Netherlands
[2] Northwestern Univ, Feinberg Sch Med, Div Gastroenterol & Hepatol, Dept Med, Chicago, IL 60611 USA
[3] Univ Leuven, ExpORL, Dept Neurosci, Leuven, Belgium
[4] Univ Leuven, Translat Res Ctr Gastrointestinal Dis, Leuven, Belgium
[5] Flinders Univ S Australia, Sch Med, Bedford Pk, SA, Australia
基金
英国医学研究理事会;
关键词
dysphagia perception; high-resolution impedance manometry; non-obstructive dysphagia; pressure flow analysis; FLOW TIME; ABNORMALITIES;
D O I
10.1111/nmo.13505
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background High-resolution impedance manometry (HRIM) allows evaluation of esophageal bolus retention, flow, and pressurization. We explored novel HRIM measures and assessed their temporal relationship to dysphagia symptoms for boluses of different volume and consistency in non-obstructive dysphagia (NOD) patients. Methods Thirty-three NOD patients (n = 19 minor or no disorder of peristalsis ("Normal") and n = 14 esophagogastric junction outflow obstruction ("EGJOO")) were evaluated with HRIM. Patients were administered 5 and 10 mL liquid, semisolid, and 2 and 4 cm solid boluses and indicated bolus perception during individual swallows using a 5-point Likert scale. HRIM was analyzed to assess Chicago Classification and pressure flow metrics, esophageal impedance integral (EII) ratio, and bolus flow time (BFT). Key Results Overall, bolus perception increased with increasing bolus consistency (P < 0.001), but did not differ significantly between EGJOO and Normal patients. EGJOO patients had higher IRP4, higher levels of bolus residual (ie, EII ratio and IR), and restricted esophageal emptying. The results for linking semisolid bolus perception to semisolid-derived measures revealed more biomechanically plausible and consistent patterns when compared to those derived for liquid boluses. In Normal patients, perception of boluses of heavier viscosity was related to higher bolus flow resistance during transport, whilst in EGJOO, perception was related to restriction of esophageal emptying. Conclusion & Inferences These novel pressure-impedance measures may aid in the evaluation of NOD patients by revealing abnormal motor patterns, which may explain symptom generation. Future studies are needed to evaluate which of these measures are worthy of calculation and to establish protocol settings that allow for their meaningful interpretation.
引用
收藏
页数:10
相关论文
共 15 条
  • [1] Inter-rater agreement of novel high-resolution impedance manometry metrics: Bolus flow time and esophageal impedance integral ratio
    Carlson, D. A.
    Lin, Z.
    Kou, W.
    Pandolfino, J. E.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2018, 30 (06)
  • [2] High-resolution impedance manometry parameters enhance the esophageal motility evaluation in non-obstructive dysphagia patients without a major Chicago Classification motility disorder
    Carlson, D. A.
    Omari, T.
    Lin, Z.
    Rommel, N.
    Starkey, K.
    Kahrilas, P. J.
    Tack, J.
    Pandolfino, J. E.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2017, 29 (03)
  • [3] Characterization of esophageal pressure-flow abnormalities in patients with non-obstructive dysphagia and normal manometry findings
    Chen, Chien-Lin
    Yi, Chih-Hsun
    Liu, Tso-Tsai
    Hsu, Ching-Sheng
    Omari, Taher I.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (06) : 946 - 953
  • [4] Esophageal distension during bolus transport: can it be detected by intraluminal impedance recordings?
    Kim, J. H.
    Mittal, R. K.
    Patel, N.
    Ledgerwood, M.
    Bhargava, V.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2014, 26 (08) : 1122 - 1130
  • [5] High-resolution impedance manometry measurement of bolus flow time in achalasia and its correlation with dysphagia
    Lin, Z.
    Carlson, D. A.
    Dykstra, K.
    Sternbach, J.
    Hungness, E.
    Kahrilas, P. J.
    Ciolino, J. D.
    Pandolfino, J. E.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2015, 27 (09) : 1232 - 1238
  • [6] Parameters for quantifying bolus retention with high-resolution impedance manometry
    Lin, Z.
    Nicodeme, F.
    Lin, C. -Y.
    Mogni, B.
    Friesen, L.
    Kahrilas, P. J.
    Pandolfino, J. E.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2014, 26 (07) : 929 - 936
  • [7] Flow time through esophagogastric junction derived during high-resolution impedance-manometry studies: a novel parameter for assessing esophageal bolus transit
    Lin, Zhiyue
    Imam, Hala
    Nicodeme, Frederic
    Carlson, Dustin A.
    Lin, Chen-Yuan
    Yim, Brandon
    Kahrilas, Peter J.
    Pandolfino, John E.
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2014, 307 (02): : G158 - G163
  • [8] Susceptibility to dysphagia after fundoplication revealed by novel automated impedance manometry analysis
    Myers, J. C.
    Nguyen, N. Q.
    Jamieson, G. G.
    Van't Hek, J. E.
    Ching, K.
    Holloway, R. H.
    Dent, J.
    Omari, T. I.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 (09) : 812 - +
  • [9] Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD) (vol 31, pg 232, 2016)
    Newman, Roger
    Vilardell, Natalia
    Clave, Pere
    Speyer, Renee
    [J]. DYSPHAGIA, 2016, 31 (05) : 719 - 719
  • [10] Automated impedance-manometry analysis detects esophageal motor dysfunction in patients who have non-obstructive dysphagia with normal manometry
    Nguyen, N. Q.
    Holloway, R. H.
    Smout, A. J.
    Omari, T. I.
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (03) : 238 - +