Economic Integration of Renewable and Conventional Power Sources-A Case Study

被引:32
作者
Awan, Muhammad Mateen Afzal [1 ]
Javed, Muhammad Yaqoob [2 ]
Asghar, Aamer Bilal [2 ]
Ejsmont, Krzysztof [3 ]
Zia-ur-Rehman [4 ]
机构
[1] Univ Management & Technol Lahore, Dept Elect Engn, Sialkot 51310, Punjab, Pakistan
[2] COMSATS Univ Islamabad, Dept Elect & Comp Engn, Lahore 54000, Punjab, Pakistan
[3] Warsaw Univ Technol, Fac Mech & Ind Engn, PL-02524 Warsaw, Poland
[4] Mirpur Univ Sci & Technol, Dept Elect Engn, Mirpur 10250, Azad Kashmir, Pakistan
基金
欧盟地平线“2020”;
关键词
microgrid; Hybrid Optimization of Multiple Energy Resources; renewable energy; optimization; sensitivity analysis; HYBRID ENERGY SYSTEM; TECHNOECONOMIC OPTIMIZATION; OPTIMAL-DESIGN; FEASIBILITY; STANDALONE; PV; ALGORITHM; ISLAND; SIMULATION; GENERATION;
D O I
10.3390/en15062141
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, we have presented an optimal microgrid design that ensures the uninterrupted energy supply to Mirpur University of Engineering and Technology (MUST), Azad Jammu and Kashmir AJK, Pakistan at the cheapest price by using reliable energy resources. The availability of energy resources, environmental viability, and economic feasibility are the key parameters of design. The available resources for the MUST site include the National grid, Solar photovoltaic (SPV), Battery bank, and Diesel generator. The data of electrical load, solar illumination, atmospheric temperature at the university, diesel fuel cost, SPV module lifetime, SPV degradation factor, SPV efficiency, SPV cost, battery cost, battery life, national grid energy price, load shedding and toxic emissions have been considered valuables in designing the hybrid micro-grid. The difference in net present cost (NPC) of the optimal design and the worst design is calculated by considering the above parameters. The proposed optimal microgrid design supplies energy to the load using SPV, Diesel generator, and battery bank with NPC of $250,546 and the renewable fraction of 99%. Whereas the worst design includes the Diesel generator and battery bank as energy supplying sources with the NPC of $2.14 M and a renewable fraction of 0%. Simulations performed using HOMER Pro software (HOMER Energy, HOMER Pro-3.11, Boulder, CO, USA) proved that after considering all the data and requirements mentioned above, out of 979 feasible designs, the proposed hybrid microgrid design is best suitable for MUST.
引用
收藏
页数:20
相关论文
共 47 条
[1]   Techno economic analysis of a wind-photovoltaic-biomass hybrid renewable energy system for rural electrification: A case study of Kallar Kahar [J].
Ahmad, Jameel ;
Imran, Muhammad ;
Khalid, Abdullah ;
Iqbal, Waseem ;
Ashraf, Syed Rehan ;
Adnan, Muhammad ;
Ali, Syed Farooq ;
Khokhar, Khawar Siddique .
ENERGY, 2018, 148 :208-234
[2]   Optimal design and analysis of grid-connected photovoltaic under different tracking systems using HOMER [J].
Al Garni, Hassan Z. ;
Awasthi, Anjali ;
Ramli, Makbul A. M. .
ENERGY CONVERSION AND MANAGEMENT, 2018, 155 :42-57
[3]   A preliminary feasibility of roof-mounted solar PV systems in the Maldives [J].
Ali, Ihsan ;
Shafiullah, G. M. ;
Urmee, Tania .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 83 :18-32
[4]  
Awan MMA, 2020, MEHRAN UNIV RES J EN, V39, P267, DOI [10.22581/muet1982.2002.05, 10.0000/22581/muet1982.2002.05]
[5]   A Novel Ten Check Maximum Power Point Tracking Algorithm for a Standalone Solar Photovoltaic System [J].
Awan, Muhammad Mateen Afzal ;
Mahmood, Tahir .
ELECTRONICS, 2018, 7 (11)
[6]  
Awan MMA, 2017, MEHRAN UNIV RES J EN, V36, P501, DOI 10.22581/muet1982.1703.07
[7]   Optimal renewable power generation systems for Busan metropolitan city in South Korea [J].
Baek, Seoin ;
Park, Eunil ;
Kim, Min-Gil ;
Kwon, Sang Jib ;
Kim, Ki Joon ;
Ohm, Jay Y. ;
del Pobil, Angel P. .
RENEWABLE ENERGY, 2016, 88 :517-525
[8]   Feasibility study and energy conversion analysis of stand-alone hybrid renewable energy system [J].
Baghdadi, Fazia ;
Mohammedi, Kamal ;
Diaf, Said ;
Behar, Omar .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :471-479
[9]   PV-wind hybrid power option for a low wind topography [J].
Bhattacharjee, Subhadeep ;
Acharya, Shantanu .
ENERGY CONVERSION AND MANAGEMENT, 2015, 89 :942-954
[10]   Multi agent system solution to microgrid implementation [J].
Boudoudouh, Soukaina ;
Maaroufi, Mohamed .
SUSTAINABLE CITIES AND SOCIETY, 2018, 39 :252-261