In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators

被引:18
作者
Chiladakis, JA [1 ]
Davlouros, P [1 ]
Agelopoulos, G [1 ]
Manolis, AS [1 ]
机构
[1] Univ Patras, Sch Med, Div Cardiol, GR-26110 Patras, Greece
关键词
implantable cardioverter-defibrillators; electromagnetic interference; digital cellular telephones;
D O I
10.1053/euhj.2000.2516
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To investigate the susceptibility of implantable cardioverter defibrillators to electromagnetic interference generated by digital cellular telephones, functioning in both international transmission technologies: the Global System for Mobile Communication (GSM) and the Digital Cellular System (DCS 1800). Methods and Results In 36 patients with transvenous implantable cardioverter defibrillators from two manufacturers (Medtronic and Guidant/CPI), cellular telephones with different levels of minimal and maximal power output were tested in the transmitting and receiving mode. Evaluation was performed in activated implantable defibrillators during spontaneous cardiac activity and continuous VVI or DDD pacing to assess possible electromagnetic interference. In two patients, appropriateness of ventricular fibrillation detection and therapy was judged during telephone testing. There was no damage, reprogramming, inappropriate shock therapy or pacing inhibition during the tests. In seven pre-pectoral Medtronic implantable defibrillators, transient electromagnetic interference caused 19 erroneous sensing events, when the operating phone was held in close vicinity to the programmer head. These 'pseudo-oversensing' events, which did not result in logging of arrhythmia episodes in the device counter, were interpreted as an adverse interaction between the telephone and the programming device. Conclusion Digital cellular telephones do not represent a risk to Medtronic and Guidant/CPI recipients of the specific implantable defibrillator models herein tested.
引用
收藏
页码:1337 / 1342
页数:6
相关论文
共 18 条
[1]   Electromagnetic interference of digital and analog cellular telephones with implantable cardioverter defibrillators: In vitro and in vivo studies [J].
Barbaro, V ;
Bartolini, P ;
Bellocci, F ;
Caruso, F ;
Donato, A ;
Gabrielli, D ;
Militello, C ;
Montenero, AS ;
Zecchi, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (04) :626-634
[2]   Cellular phone interference testing of implantable cardiac defibrillators in vitro [J].
Bassen, HI ;
Moore, HJ ;
Ruggera, PS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (09) :1709-1715
[3]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[4]   UNIQUE SENSING ERRORS IN 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
KLEIMAN, RB ;
MITRA, RL ;
FLORES, BT ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1135-1140
[5]   Digital cellular telephone interaction with implantable cardioverter-defibrillators [J].
Fetter, JG ;
Ivans, V ;
Benditt, DG ;
Collins, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :623-628
[6]   Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators [J].
Groh, WJ ;
Boschee, SA ;
Engelstein, ED ;
Miles, WM ;
Burton, ME ;
Foster, PR ;
Crevey, BJ ;
Zipes, DP .
CIRCULATION, 1999, 100 (04) :387-392
[7]   State of the science: Pacemaker and defibrillator interference from wireless communication devices [J].
Hayes, DL ;
Carrillo, RG ;
Findlay, GK ;
Embrey, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1419-1430
[8]  
HAYNES DL, 1996, PACING CLIN ELECTROP, V19, P1419
[9]  
HAYNES DL, 1997, NEW ENGL J MED, V336, P1473
[10]   Implantable defibrillators and electromagnetic interference [J].
Irnich, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (07) :981-982