Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI

被引:23
|
作者
Foti, Giovanni [1 ]
Faccioli, Niccolo [2 ]
Silva, Ronaldo [3 ]
Oliboni, Eugenio [1 ]
Zorzi, Claudio [4 ]
Carbognin, Giovanni [1 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[2] Verona Univ Hosp, Dept Radiol, Verona, Italy
[3] IRCCS Sacro Cuore Don Calabria Hosp, Clin Res Unit, Negrar, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthoped Surg, Negrar, Italy
关键词
Hip joint; Magnetic resonance imaging; Multidetector computed tomography; Bone marrow; FEMORAL-HEAD; TRANSIENT OSTEOPOROSIS; CORE DECOMPRESSION; OSTEONECROSIS; RELIABILITY; FRACTURES; NECROSIS; LESIONS; UPDATE;
D O I
10.1007/s00330-020-06775-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. Methods This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males, 41 females; mean age 61.5 years, range 32-82) who were assessed by DECT and magnetic resonance imaging (MRI) within a 5-day period. Diagnostic accuracy values for diagnosing BME on a per-patient and on a per-partition-basis analysis were calculated for DECT images by two readers (R1 and R2, with 15 and 10 years of experience, respectively), using MRI as reference for diagnosis. Inter-observer agreements were calculated withk-statistics. Apvalue of < 0.05 was considered as statistically significant. Results MRI depicted BME in 44/59 patients (74.58%), with the involvement of 83/708 (11.72%) partitions. The sensitivity, specificity, and accuracy of R1 and R2 were 95.45% (42/44), 86.67% (13/15), and 93.22% (55/59) for R1, and 86.36% (38/44), 80.00% (12/15), and 84.75% (50/59) for R2. For both readers, the BME detection rate was higher in patients with severe edema (100%) in comparison to patients with mild edema (91.30% and 73.91%). In the partition-basis analysis, sensitivity, specificity, and accuracy ranges were 33.3 to 100%, 91.84 to 100%, and 88.14 to 100%, respectively. The inter-observer agreement for patients' analysis was substantial (k = 0.7065), whereas for partition analysis ranged from fair (k = 0.2976) to near-perfect (k = 1.000). Conclusion DECT can accurately identify BME around the hip joint, in comparison to MRI.
引用
收藏
页码:4098 / 4106
页数:9
相关论文
共 50 条
  • [31] Traumatic bone marrow lesions in dual-energy computed tomography
    Qiuping Ren
    Deqiu Tang
    Zhiyuan Xiong
    Heng Zhao
    Shuixing Zhang
    Insights into Imaging, 13
  • [32] Diagnostic accuracy of color-coded virtual noncalcium dual-energy CT for the assessment of bone marrow edema in sacral insufficiency fracture in comparison to MRI
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Bucher, Andreas M.
    Huizinga, Nicole A.
    Wichmann, Julian L.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [33] Spondylodiscitis of the thoraco-lumbar spine: diagnostic performance of dual-energy CT vs MRI
    Foti, Giovanni
    Longo, Chiara
    Oliboni, Eugenio
    Faccioli, Niccolo
    Sanfilippo, Lorenza
    Guerriero, Massimo
    Augelli, Raffaele
    Motta, Leonardo
    Marocco, Stefania
    EUROPEAN RADIOLOGY, 2025, 35 (03) : 1647 - 1657
  • [34] Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints
    Wu, Haijun
    Zhang, Guangfeng
    Shi, Lei
    Li, Xiuhui
    Chen, Min
    Huang, Xiaoyu
    Cao, Ximing
    Tan, Shaoheng
    Cui, Yang
    Liang, Changhong
    RADIOLOGY, 2019, 290 (01) : 157 - 164
  • [35] Diagnostic accuracy of dual-energy CT for the detection of bone marrow edema in the appendicular skeleton: a systematic review and meta-analysis
    Wilson, Mitchell P.
    Lui, Kevin
    Nobbee, Dorian
    Murad, Mohammad H.
    McInnes, Matthew D. F.
    McGrath, Trevor A.
    Katlariwala, Prayash
    Low, Gavin
    EUROPEAN RADIOLOGY, 2021, 31 (03) : 1558 - 1568
  • [36] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232
  • [37] Optimising dual-energy CT scan parameters for virtual non-calcium imaging of the bone marrow: a phantom study
    Mueller, Felix C.
    Borgesen, Henrik
    Gosvig, Kasper
    Rodell, Anders
    Booz, Christian
    Schmidt, Bernhard
    Krauss, Bernhard
    Boesen, Mikael
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01)
  • [38] Detection of bone marrow edema in differential diagnoses of odontogenic cysts using dual-energy computed tomography
    Hasegawa, Takumi
    Arimoto, Satomi
    Saito, Izumi
    Yatagai, Nanae
    Murakami, Aki
    Sasaki, Aki
    Tadokoro, Yoshiaki
    Tani, Wakiko
    Kagawa, Kiyosumi
    Akashi, Masaya
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2023, 27 (04): : 675 - 684
  • [39] Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis
    Suh, Chong Hyun
    Yun, Seong Jong
    Jin, Wook
    Lee, Sun Hwa
    Park, So Young
    Ryu, Chang-Woo
    EUROPEAN RADIOLOGY, 2018, 28 (10) : 4182 - 4194
  • [40] Use of dual-energy CT to detect and depict bone marrow oedema in rheumatoid arthritis: is it ready to substitute MRI?
    Wu, Haijun
    Zhang, Guangfeng
    Huang, Xiaoyu
    Liang, Changhong
    ANNALS OF THE RHEUMATIC DISEASES, 2019, 78 (09) : E89 - E89