Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI

被引:23
|
作者
Foti, Giovanni [1 ]
Faccioli, Niccolo [2 ]
Silva, Ronaldo [3 ]
Oliboni, Eugenio [1 ]
Zorzi, Claudio [4 ]
Carbognin, Giovanni [1 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[2] Verona Univ Hosp, Dept Radiol, Verona, Italy
[3] IRCCS Sacro Cuore Don Calabria Hosp, Clin Res Unit, Negrar, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthoped Surg, Negrar, Italy
关键词
Hip joint; Magnetic resonance imaging; Multidetector computed tomography; Bone marrow; FEMORAL-HEAD; TRANSIENT OSTEOPOROSIS; CORE DECOMPRESSION; OSTEONECROSIS; RELIABILITY; FRACTURES; NECROSIS; LESIONS; UPDATE;
D O I
10.1007/s00330-020-06775-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. Methods This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males, 41 females; mean age 61.5 years, range 32-82) who were assessed by DECT and magnetic resonance imaging (MRI) within a 5-day period. Diagnostic accuracy values for diagnosing BME on a per-patient and on a per-partition-basis analysis were calculated for DECT images by two readers (R1 and R2, with 15 and 10 years of experience, respectively), using MRI as reference for diagnosis. Inter-observer agreements were calculated withk-statistics. Apvalue of < 0.05 was considered as statistically significant. Results MRI depicted BME in 44/59 patients (74.58%), with the involvement of 83/708 (11.72%) partitions. The sensitivity, specificity, and accuracy of R1 and R2 were 95.45% (42/44), 86.67% (13/15), and 93.22% (55/59) for R1, and 86.36% (38/44), 80.00% (12/15), and 84.75% (50/59) for R2. For both readers, the BME detection rate was higher in patients with severe edema (100%) in comparison to patients with mild edema (91.30% and 73.91%). In the partition-basis analysis, sensitivity, specificity, and accuracy ranges were 33.3 to 100%, 91.84 to 100%, and 88.14 to 100%, respectively. The inter-observer agreement for patients' analysis was substantial (k = 0.7065), whereas for partition analysis ranged from fair (k = 0.2976) to near-perfect (k = 1.000). Conclusion DECT can accurately identify BME around the hip joint, in comparison to MRI.
引用
收藏
页码:4098 / 4106
页数:9
相关论文
共 50 条
  • [1] Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI
    Giovanni Foti
    Niccolò Faccioli
    Ronaldo Silva
    Eugenio Oliboni
    Claudio Zorzi
    Giovanni Carbognin
    European Radiology, 2020, 30 : 4098 - 4106
  • [2] Bone marrow edema in non-traumatic hip: high accuracy of dual-energy CT with water-hydroxyapatite decomposition imaging
    Son, Wookon
    Park, Chankue
    Jeong, Hee Seok
    Song, You Seon
    Lee, In Sook
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2191 - 2198
  • [3] Identification of bone marrow edema around the ankle joint in non-traumatic patients: Diagnostic accuracy of dual-energy computed tomography
    Foti, Giovanni
    Guerriero, Massimo
    Faccioli, Niccolo
    Fighera, Alessandro
    Romano, Luigi
    Zorzi, Claudio
    Carbognin, Giovanni
    CLINICAL IMAGING, 2021, 69 : 341 - 348
  • [4] Bone marrow edema in non-traumatic hip: high accuracy of dual-energy CT with water-hydroxyapatite decomposition imaging
    Wookon Son
    Chankue Park
    Hee Seok Jeong
    You Seon Song
    In Sook Lee
    European Radiology, 2020, 30 : 2191 - 2198
  • [5] Identification of Non-Traumatic Bone Marrow Oedema: The Pearls and Pitfalls of Dual-Energy CT (DECT)
    Foti, Giovanni
    Serra, Gerardo
    Iacono, Venanzio
    Marocco, Stefania
    Bertoli, Giulia
    Gori, Stefania
    Zorzi, Claudio
    TOMOGRAPHY, 2021, 7 (03) : 387 - 396
  • [6] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Mantovani, William
    Faccioli, Niccolo
    Crivellari, Giacomo
    Romano, Luigi
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2021, 126 (03): : 405 - 413
  • [7] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Catania, Matteo
    Caia, Simone
    Romano, Luigi
    Beltramello, Alberto
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (10): : 1028 - 1036
  • [8] A Comparison of Dual-Energy CT with MRI in the Detection of Traumatic Bone Marrow Edema in Distal Extremity Bones
    Kaya, Ahmet Turan
    Ozdemir, Zeynep Maras
    Erbay, Mehmet Fatih
    Kahraman, Aysgul Sagir
    Karaca, Leyla
    Karakaplan, Mustafa
    Gurbuz, Sukru
    JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (05): : 494 - 504
  • [9] Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid
    Koch, Vitali
    Mueller, Felix Christoph
    Gosvig, Kasper
    Albrecht, Moritz H.
    Yel, Ibrahim
    Lenga, Lukas
    Martin, Simon S.
    Cavallaro, Marco
    Wichmann, Julian L.
    Mader, Christoph
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Cicero, Giuseppe
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 4428 - 4437
  • [10] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    William Mantovani
    Niccolò Faccioli
    Giacomo Crivellari
    Luigi Romano
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2021, 126 : 405 - 413