The application analysis of the on-line monitoring system of dissolved gas in transformer oil

被引:1
作者
Li Yanming [1 ]
Liu Gang [1 ]
Liang Ying [2 ]
Xing Yan [3 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510640, Peoples R China
[2] Yunfu Power Plant, Yunfu 537300, Guangdong, Peoples R China
[3] Northeast Normal Univ, Dept Chem, Changchun 130024, Peoples R China
来源
2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA | 2007年
关键词
D O I
10.1109/CEIDP.2007.4451596
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Technology of on-line monitoring of dissolved gas in transformer oil is the focus of attention nowadays. As the technologies of computer, macromolecule materials and optical spectrum analysis develop rapidly, the on-line monitoring devices are more and more perfect and are used more popular in electric power production. In this paper, the on-fine monitoring device of dissolved gas in transformer oil typed HYDRAN20li is set as an example and the working principle and the properties of this kind of systems are introduced. Some common problems in using on-line monitoring devices are brought up and the settlement methods are described. This paper gives consultation to the maintaining of the on-line monitoring devices.
引用
收藏
页码:747 / +
页数:2
相关论文
共 50 条
  • [21] Interpretation of Dissolved Gas Analysis in Transformer Oil using Fuzzy Logic System
    SuganyaBharathi, M.
    Iruthayarajan, M. Willjuice
    Shunmugam, S. Sudalai
    Kalaivani, L.
    2013 INTERNATIONAL CONFERENCE ON POWER, ENERGY AND CONTROL (ICPEC), 2013, : 245 - 249
  • [22] An improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system
    Lesieutre, BC
    Hagman, WH
    Kirtley, JL
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) : 249 - 256
  • [23] Improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system
    Massachusetts Inst of Technology, Cambridge, United States
    IEEE Trans Power Delivery, 1 (249-256):
  • [24] Effect of Temperature on Oil-gas Separation in Membrane Separation based Transformer On-line Monitoring
    Wang, Fei
    Zhao, Liang
    He, Peng
    Zhao, Xuezeng
    MECHATRONICS AND INTELLIGENT MATERIALS, PTS 1 AND 2, 2011, 211-212 : 389 - 394
  • [25] Application of silting principle to on-line monitoring oil contamination in hydraulic system
    Yao, Chengyu
    Zhao, Jingyi
    Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2006, 17 (02): : 124 - 127
  • [26] The design of transformer on-line monitoring system based on DSP
    Ding, Tengfei
    Yin, Chunyuan
    Cao, Yunxia
    ENERGY SCIENCE AND APPLIED TECHNOLOGY, 2016, : 493 - 495
  • [27] Wireless Monitoring and Analysing System of Dissolved Gases in the Transformer Oil
    Cao, Jian
    Qian, Suxiang
    Hu, Hongsheng
    Yang, Shixi
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 5152 - +
  • [28] Monitoring of oil-dissolved gas and transformer faults diagnosis on site
    Xue, WD
    Ge, QR
    Cao, JM
    Lan, ZD
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 401 - 404
  • [29] On-line Monitoring of Transformer Oil Degradation Based on Fiber Optic Sensors
    Kim, Tae-Young
    Kim, Jong-Eun
    Suh, Kwang S.
    SENSORS AND MATERIALS, 2008, 20 (05) : 201 - 209
  • [30] Transformer Fault Diagnosis Based on the analysis of dissolved gas in oil
    Sun, Jie
    Xing, Jiuxia
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 95 - 97