Detailed Monte Carlo simulation of energy integrating and photon counting semiconductor detectors

被引:0
|
作者
Mendesa, Hitalo R. [1 ]
Tomala, Alessandra [1 ]
机构
[1] Univ Estadual Campinas, Gleb Wataghin Inst Phys, BR-13057413 Campinas, SP, Brazil
来源
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING | 2022年 / 12031卷
基金
瑞典研究理事会;
关键词
Monte Carlo simulation; detection; energy integrating; photon counting;
D O I
10.1117/12.2607891
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray imaging techniques widely employ semiconductor detectors. Energy integrating (EI) detectors are used in digital radiography and photon counting (PC) in CT. This work aims to implement a detailed Monte Carlo modeling of these sensors. The model was divided into radiation interaction and electron-hole pairs (EHP) creation and dispersion. The PENELOPE code simulated the radiation transport. In each electron interaction, the absorbed energy was converted into EHP considering the pair creation energy and the Fano factor. The detection position was sampled using a Gaussian distribution, where the standard deviation was from the Einstein diffusion equation. The Hetch equation models the charge trapping. In the PC mode, the photon was counted if the energy deposited was higher than a threshold (ethr). Monoenergetic pencil beams between 10 and 100 keV were simulated, with 107 histories. The detector material was cadmium tellurite, with 50 mu m pixel size, whose thicknesses, applied electric field, and ethr vary, respectively from 250 to 1000 mu m, 0.01 to 1 V/mu m, and from 1 to 50 keV. The results show a wider detector response as the beam energy increases. For energies above 32 keV the fluorescence is greatly responsible for this spread. The detector's efficiency increases with the sensor thickness and decreases with the photon energy. Charge trapping decreases the efficiency up to 43,53%. For the PC mode, an ethr increase yields a narrower detector response and increases the image noise. This study provides a detailed detector modeling and, consequently, insight into the imaging system's fundamental limitations.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A Monte Carlo simulation study on effects of energy weighted dual-energy subtraction images with indirect photon-counting detector in mammography
    Baek, C-H
    Lee, S-J
    Cho, I-H
    Kim, D.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (03):
  • [42] MONTE-CARLO SIMULATION OF GAMMA-RAY SPECTRA FROM SEMICONDUCTOR-DETECTORS
    OLSCHNER, F
    LUND, JC
    STERN, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1176 - 1179
  • [43] Determination of photon quantity in Monte Carlo simulation
    Xue Yang
    Gang Li
    Ling Lin
    Optical and Quantum Electronics, 2016, 48
  • [44] Accelerating photon transport in Monte Carlo simulation
    Ogawa, K
    Takahashi, S
    Satori, Y
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1147 - 1151
  • [45] Determination of photon quantity in Monte Carlo simulation
    Yang, Xue
    Li, Gang
    Lin, Ling
    OPTICAL AND QUANTUM ELECTRONICS, 2016, 48 (09)
  • [46] Strict detailed balance is unnecessary in Monte Carlo simulation
    Manousiouthakis, VI
    Deem, MW
    JOURNAL OF CHEMICAL PHYSICS, 1999, 110 (06): : 2753 - 2756
  • [47] Monte Carlo simulation on the water microcluster in the detailed balance
    Suzuki, K
    NUCLEATION AND ATMOSPHERIC AEROSOLS 1996, 1996, : 157 - 160
  • [48] A detailed Monte Carlo simulation for the Belle TOF system
    Nam, JW
    Choi, YI
    Kim, DW
    Kim, JH
    Casey, BCK
    Jones, M
    Olsen, SL
    Peters, M
    Rodriguez, JL
    Varner, G
    Zheng, Y
    Gabyshev, N
    Kichimi, H
    Yashima, J
    Zhang, J
    Kim, TH
    Kwon, YJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2): : 54 - 68
  • [49] Strict detailed balance is unnecessary in Monte Carlo simulation
    Manousiouthakis, Vasilios I.
    Deem, Michael W.
    Journal of Chemical Physics, 1999, 110 (2-12): : 2753 - 2756
  • [50] Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams
    Wang, Lille L. W.
    Klein, David
    Beddar, A. Sam
    MEDICAL PHYSICS, 2010, 37 (10) : 5279 - 5286